scholarly journals Diagnostic accuracy of spleen stiffness to evaluate portal hypertension and esophageal varices in chronic liver disease: a systematic review and meta-analysis

Author(s):  
Xing Hu ◽  
Xiaojie Huang ◽  
Jianhua Hou ◽  
Lei Ding ◽  
Chunling Su ◽  
...  

Abstract Objectives To systematically review studies on the diagnostic accuracy of spleen stiffness measurement (SSM) for the detection of clinical significant portal hypertension (CSPH), severe portal hypertension (SPH), esophageal varices (EV), and high-risk esophageal varices (HREV) in patients with chronic liver diseases (CLD). Methods Through a systematic search, we identified 32 studies reporting the accuracy of SSM for the diagnosis of portal hypertension (PH) and/or EV in adults with CLD. A bivariate random-effects model was performed to estimate pooled sensitivity, specificity, likelihood ratio, positive predictive value (PPV), negative predictive value (NPV), and diagnostic odds ratios (DOR). The clinical utility of SSM was evaluated by Fagan plot. Results A total of 32 studies assessing 3952 patients were included in this meta-analysis. The pooled sensitivities of SSM were 0.85 (95% confidence interval (CI), 0.69–0.93) for CSPH; 0.84 (95% CI, 0.75–0.90) for SPH; 0.90 (95% CI, 0.83–0.94) for any EV; and 0.87 (95% CI, 0.77–0.93) for HREV. The pooled specificities of SSM were 0.86 (95% CI, 0.74–0.93) for CSPH; 0.84 (95% CI, 0.72–0.91) for SPH; 0.73 (95% CI, 0.66–0.79) for EV; and 0.66 (95% CI, 0.53–0.77) for HREV. Summary PPV and NPV of SSM for detecting HREV were 0.54 (95% CI, 0.47–0.62) and 0.88 (95% CI, 0.81–0.95), respectively. Conclusions Our meta-analysis suggests that SSM could be used as a helpful surveillance tool in management of CLD patients and was quite useful for ruling out the presence of HREV thereby avoiding unnecessary endoscopy. Key Points • SSM could be used to rule out the presence of HREV in patients with CLD thereby avoiding unnecessary endoscopy. • SSM has significant diagnostic value for CSPH and SPH with high sensitivity and specificity in patients with CLD. • SSM could be used as a helpful surveillance tool for clinicians managing CLD patients.

Author(s):  
Xing Hu ◽  
Xiaojie Huang ◽  
Jianhua Hou ◽  
Lei Ding ◽  
Chunling Su ◽  
...  

The original version of this article, published on 24 September 2020, unfortunately contained a mistake.


2020 ◽  
Vol 08 (11) ◽  
pp. E1623-E1632
Author(s):  
Carlos Robles-Medranda ◽  
Roberto Oleas ◽  
Miguel Puga-Tejada ◽  
Manuel Valero ◽  
Raquel Del Valle ◽  
...  

Abstract Background and study aims Assessment of endoscopic ultrasonography (EUS)-elastography of the liver and spleen may identify patients with portal hypertension secondary to chronic liver disease. We aimed to evaluate use of EUS-elastography of the liver and spleen in identification of portal hypertension in patients with chronic liver disease. Patients and methods This was a single-center, diagnostic cohort study. Consecutive patients with liver cirrhosis and portal hypertension underwent EUS-elastography of the liver and spleen. Patients without a history of liver disease were enrolled as controls. The primary outcome was diagnostic yield of liver and spleen stiffness measurement via EUS-elastography in prediction of portal hypertension secondary to chronic liver cirrhosis. Cutoff values were defined through Youden’s index. Overall accuracy was calculated for parameters with an area under the receiver operating characteristic (AUROC) curve ≥ 80 %. Results Among the 61 patients included, 32 had cirrhosis of the liver. Liver and spleen stiffness was measured by the strain ratio and strain histogram, with sensitivity/(1 − specificity) AUROC values ≥ 80 %. For identification of patients with cirrhosis and portal hypertension, the liver strain ratio (SR) had a sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 84.3 %, 82.8 %, 84.4 %, and 82.8 %, respectively; the liver strain histogram (SH) had values of 87.5 %, 69.0 %, 75.7 %, and 83.3 %, respectively. EUS elastography of the spleen via the SR reached a sensitivity, specificity, PPV, and NPV of 87.5 %, 69.0 %, 75.7 %, and 83.3 %, respectively, whereas the values of SH were 56.3 %, 89.7 %, 85.7 %, and 65.0 %, respectively. Conclusion Endoscopic ultrasonographic elastography of the liver and spleen is useful for diagnosis of portal hypertension in patients with cirrhosis.


Author(s):  
Naglaa El-Toukhy Ramadan El-Toukhy ◽  
Sharaf Elsayed Ali Hassanien ◽  
Ramy A. Metwaly ◽  
Medhat A. Khalil ◽  
Badawy A. Abdulaziz

Background and Study Aims: Portal hypertension is one of the most important complications of liver cirrhosis. The prevalence of varices among cirrhotic patients is variable. Therefore, endoscopic screening of all patients with liver cirrhosis would result in a large number of unnecessary additional burdens to endoscopic units. Our aim was to assess the diagnostic accuracy of spleen stiffness measured by transient elastography (Fibroscan) for prediction of the presence of varices in patients with hepatitis C related cirrhosis. Patients and Methods: The study was carried out on 100 patients with HCV-induced cirrhosis and were divided into 2 groups according to presence or absence of varices by Esophago-gastro-duodenoscopy: Group I: patients with HCV-induced cirrhosis with varices; Group II: patients with HCV-induced cirrhosis without varices. Clinical and laboratory parameters, andominal ultrasonography, Upper gastrointestinal endoscopy and transient elastography to assess the liver and spleen stiffness were carried out to all studied persons. Results: Spleen stiffness had significant diagnostic value to differentiate between cirrhotic patients with varices and cirrhotic patients without varices , it had significant diagnostic value in presence of esophageal varices at cut-off (≥46.4 K Pascal) the sensitivity for detection of esophageal varices was 93%, specificity 100%, positive predictive value (PPV) was 80%, negative predictive value (NPV) was 100%; accuracy was 95% and area under the curve was 0.98 denoting that spleen stiffness is a good predictor of esophageal varices. Conclusion: Spleen stiffness was considered as an excellent predictor of esophageal varices and better than liver stiffness in prediction of esophageal varices presence and had significant diagnostic value to differentiate between the patients with varices and patients without varices at cut off (≥46.4 K Pascal) and it may have a role in variceal grading.


2019 ◽  
Vol 36 (1) ◽  
pp. e4.2-e4
Author(s):  
Caitlin Wilson ◽  
Clare Harley ◽  
Stephanie Steels

BackgroundPre-hospital clinicians are involved in examining, treating and diagnosing patients. The accuracy of pre-hospital diagnoses is evaluated using diagnostic accuracy studies. We undertook a systematic review of published literature to provide an overview of how accurately pre-hospital clinicians diagnose patients compared to hospital doctors. A bivariate meta-analysis was incorporated to examine the range of diagnostic sensitivity and specificity.MethodsWe searched MEDLINE, CINAHL, Embase, AMED and the Cochrane Database of Systematic Reviews from 1946 to 7th May 2016 for studies where patients had been given a diagnosis by pre-hospital clinicians and hospital doctors. Key words focused on study type (‘diagnostic accuracy’), outcomes (sensitivity, specificity, likelihood ratio?, predictive value?) and setting (paramedic*, pre-hospital, ambulance, ‘emergency service?’, ‘emergency medical service?’, ‘emergency technician?’). The sole researcher screened titles and abstracts to ensure eligibility criteria were met, as well as assessing methodological quality using QUADAS-2.Results2941 references were screened by title and/or abstract. Eleven studies encompassing 3 84 985 patients were included after full-text review. The types of diagnoses in one of the studies encompassed all possible diagnoses and in the other studies focused on sepsis, stroke and myocardial infarction. Sensitivity estimates ranged from 32%–100% and specificity estimates from 14%–100%. Eight of the studies were deemed to have a low risk of bias and were incorporated into a meta-analysis, which showed a pooled sensitivity of 0.74 (0.62, 0.82) and a pooled specificity of 0.94 (0.87, 0.97).ConclusionsCurrent published research suggests that diagnoses made by pre-hospital clinicians have high sensitivity and even higher specificity. However, the paucity and varying quality of eligible studies indicates that further pre-hospital diagnostic accuracy studies are warranted especially in the field of non-life-threatening conditions and trauma.


2012 ◽  
Vol 33 (1) ◽  
pp. 62-71 ◽  
Author(s):  
Ke-Qing Shi ◽  
Yu-Chen Fan ◽  
Zhen-Zhen Pan ◽  
Xian-Feng Lin ◽  
Wen-Yue Liu ◽  
...  

2021 ◽  
Author(s):  
Jiangfeng Wu ◽  
Yue Sun ◽  
Yunlai Wang ◽  
Lijing Ge ◽  
Yun Jin ◽  
...  

Aims: In the present study, a meta-analysis was performed to evaluate the diagnostic value of endobronchial ultrasound (EBUS) elastography for differentiating benign and malignant hilar and mediastinal lymph nodes (LNs). Material and methods: A comprehensive literature search was carried out through PubMed, Embase, and Cochrane Library. Two authors screened the papers and extracted the data independently and any discrepancies were resolved by discussion. The methodolog-ical quality of each included study was assessed by the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and area under the curve were calculated to evaluate the value of EBUS elastography for hilar and mediastinal LNs. Results: Seventeen studies with the number of 2307 LNs were included. There was significant heterogeneity across the included studies. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio for the diagnosis of hilar and mediastinal LNs by EBUS elastography were 0.90 (95% confidence interval [CI], 0.84-0.94), 0.78 (95% CI, 0.74-0.81), 4.1 (95% CI, 3.4-4.9), 0.12 (95% CI, 0.07-0.21) and 33 (95% CI, 17-64), respectively. Furthermore, area under the curve was calculated to be 0.86 (95% CI, 0.82-0.88). Conclusion: EBUS elastography is a valuable technology in the differentiation of benign and malignant hilar and mediastinal LNs and could provide supplementary diagnostic information during endobronchial ultrasound-guided transbronchial needle aspiration. The combination of EBUS elastography and B-mode EBUS could improve the diagnostic accuracy for hilar and mediastinal LNs.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Salama Bin Hendi ◽  
Zainab A. Malik ◽  
Amar Hassan Khamis ◽  
Fadil Y. A. Al-Najjar

Abstract Background Diagnosis of Group A Streptococcus (GAS) pharyngitis in children is hindered by variable sensitivity of clinical criteria and rapid Strep A tests (SAT), resulting in reliance on throat cultures as the gold standard for diagnosis. Delays while awaiting culture reports result in unnecessary antibiotic prescriptions among children, contributing to the spread of antimicrobial resistance (AMR). Methods Diagnostic accuracy study of an automated SAT (A-SAT) in children up to 16 years of age presenting to an emergency room with signs and symptoms of pharyngitis between March and June 2019. Paired throat swabs for A-SAT and culture were collected. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for A-SAT were calculated. Results Two hundred and ninety-one children were included in this study. 168 (57.7%) were boys and the mean age was 4.2 years. A-SAT was positive in 94 (32.3%) and throat culture was positive in 90 (30.9%) children. A-SAT and throat culture results showed a high level of consistency in our cohort. Only 6 (2%) children had inconsistent results, demonstrating that the A-SAT has a high sensitivity (98.9%), specificity (97.5%), PPV (94.7%) and NPV (99.5%) for the diagnosis of GAS pharyngitis in children. Only 92 (32%) children were prescribed antibiotics while the vast majority (68%) were not. Conclusions A-SAT is a quick and reliable test with diagnostic accuracy comparable to throat culture. Its widespread clinical use can help limit antibiotic prescriptions to children presenting with pharyngitis, thus limiting the spread of AMR.


2013 ◽  
Vol 39 (3) ◽  
pp. 263-271 ◽  
Author(s):  
G. S. I. Sulkers ◽  
N. W. L. Schep ◽  
M. Maas ◽  
C. M. A. M. van der Horst ◽  
J. C. Goslings ◽  
...  

Ruptures of the scapholunate ligament (SLL) may cause carpal instability, also known as scapholunate dissociation (SLD). SLD may lead to osteoarthritis of the radiocarpal and midcarpal joints. The aim of this retrospective study was to determine the diagnostic value of wrist cineradiography in detecting SLD. All cineradiographic studies made during a 24 year period were retrieved. All patients who underwent the confirmation method (arthroscopy and/or arthrotomy) and cineradiography were included. In total, 84 patients met the inclusion criteria. Sensitivity, specificity, likelihood ratio, positive predictive value, negative predictive value, and diagnostic accuracy for detecting SLD were calculated for radiography and cineradiography. Cineradiography had a sensitivity of 90%, a specificity of 97%, and a diagnostic accuracy of 0.93 in detecting SLD. Radiography had a sensitivity of 81%, a specificity of 80%, and a diagnostic accuracy of 0.81. Cineradiography has a high diagnostic value for diagnosing SLDs. A positive cineradiography markedly increases the post-test probability of SLD.


Sign in / Sign up

Export Citation Format

Share Document