PP9 A systematic review and meta-analysis of pre-hospital diagnostic accuracy studies

2019 ◽  
Vol 36 (1) ◽  
pp. e4.2-e4
Author(s):  
Caitlin Wilson ◽  
Clare Harley ◽  
Stephanie Steels

BackgroundPre-hospital clinicians are involved in examining, treating and diagnosing patients. The accuracy of pre-hospital diagnoses is evaluated using diagnostic accuracy studies. We undertook a systematic review of published literature to provide an overview of how accurately pre-hospital clinicians diagnose patients compared to hospital doctors. A bivariate meta-analysis was incorporated to examine the range of diagnostic sensitivity and specificity.MethodsWe searched MEDLINE, CINAHL, Embase, AMED and the Cochrane Database of Systematic Reviews from 1946 to 7th May 2016 for studies where patients had been given a diagnosis by pre-hospital clinicians and hospital doctors. Key words focused on study type (‘diagnostic accuracy’), outcomes (sensitivity, specificity, likelihood ratio?, predictive value?) and setting (paramedic*, pre-hospital, ambulance, ‘emergency service?’, ‘emergency medical service?’, ‘emergency technician?’). The sole researcher screened titles and abstracts to ensure eligibility criteria were met, as well as assessing methodological quality using QUADAS-2.Results2941 references were screened by title and/or abstract. Eleven studies encompassing 3 84 985 patients were included after full-text review. The types of diagnoses in one of the studies encompassed all possible diagnoses and in the other studies focused on sepsis, stroke and myocardial infarction. Sensitivity estimates ranged from 32%–100% and specificity estimates from 14%–100%. Eight of the studies were deemed to have a low risk of bias and were incorporated into a meta-analysis, which showed a pooled sensitivity of 0.74 (0.62, 0.82) and a pooled specificity of 0.94 (0.87, 0.97).ConclusionsCurrent published research suggests that diagnoses made by pre-hospital clinicians have high sensitivity and even higher specificity. However, the paucity and varying quality of eligible studies indicates that further pre-hospital diagnostic accuracy studies are warranted especially in the field of non-life-threatening conditions and trauma.

2018 ◽  
pp. emermed-2018-207588
Author(s):  
Caitlin Wilson ◽  
Clare Harley ◽  
Stephanie Steels

IntroductionParamedics are involved in examining, treating and diagnosing patients. The accuracy of these diagnoses is evaluated using diagnostic accuracy studies. We undertook a systematic review of published literature to provide an overview of how accurately paramedics diagnose patients compared with hospital doctors. A bivariate meta-analysis was incorporated to examine the range of diagnostic sensitivity and specificity.MethodsWe searched MEDLINE, CINAHL, Embase, AMED and the Cochrane Database from 1946 to 7 May 2016 for studies where patients had been given a diagnosis by paramedics and hospital doctors. Keywords focused on study type (‘diagnostic accuracy’), outcomes (sensitivity, specificity, likelihood ratio?, predictive value?) and setting (paramedic*, pre-hospital, ambulance, ‘emergency service?’, ‘emergency medical service?’, ‘emergency technician?’).Results2941 references were screened by title and/or abstract. Eleven studies encompassing 384 985 patients were included after full-text review. The types of diagnoses in one of the studies encompassed all possible diagnoses and in the other studies focused on sepsis, stroke and myocardial infarction. Sensitivity estimates ranged from 32% to 100% and specificity estimates from 14% to 100%. Eight of the studies were deemed to have a low risk of bias and were incorporated into a meta-analysis which showed a pooled sensitivity of 0.74 (0.62 to 0.82) and a pooled specificity of 0.94 (0.87 to 0.97).DiscussionCurrent published research suggests that diagnoses made by paramedics have high sensitivity and even higher specificity. However, the paucity and varying quality of studies indicates that further prehospital diagnostic accuracy studies are warranted especially in the field of non-life-threatening conditions.PROSPERO registration numberCRD42016039306.


2019 ◽  
Vol 57 (6) ◽  
Author(s):  
Ali Pormohammad ◽  
Mohammad Javad Nasiri ◽  
Timothy D. McHugh ◽  
Seyed Mohammad Riahi ◽  
Nathan C. Bahr

ABSTRACTThe diagnosis of tuberculous meningitis (TBM) is difficult and poses a significant challenge to physicians worldwide. Recently, nucleic acid amplification (NAA) tests have shown promise for the diagnosis of TBM, although their performance has been variable. We undertook a systematic review and meta-analysis to evaluate the diagnostic accuracy of NAA tests with cerebrospinal fluid (CSF) samples against that of culture as the reference standard or a combined reference standard (CRS) for TBM. We searched the Embase, PubMed, Web of Science, and Cochrane Library databases for the relevant records. The QUADAS-2 tool was used to assess the quality of the studies. Diagnostic accuracy measures (i.e., sensitivity and specificity) were pooled with a random-effects model. All statistical analyses were performed with STATA (version 14 IC; Stata Corporation, College Station, TX, USA), Meta-DiSc (version 1.4 for Windows; Cochrane Colloquium, Barcelona, Spain), and RevMan (version 5.3; The Nordic Cochrane Centre, the Cochrane Collaboration, Copenhagen, Denmark) software. Sixty-three studies comprising 1,381 cases of confirmed TBM and 5,712 non-TBM controls were included in the final analysis. These 63 studies were divided into two groups comprising 71 data sets (43 in-house tests and 28 commercial tests) that used culture as the reference standard and 24 data sets (21 in-house tests and 3 commercial tests) that used a CRS. Studies which used a culture reference standard had better pooled summary estimates than studies which used CRS. The overall pooled estimates of sensitivity, specificity, positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of the NAA tests against culture were 82% (95% confidence interval [CI], 75 to 87%), 99% (95% CI, 98 to 99%), 58.6 (95% CI, 35.3 to 97.3), and 0.19 (95% CI, 0.14 to 0.25), respectively. The pooled sensitivity, specificity, PLR, and NLR of NAA tests against CRS were 68% (95% CI, 41 to 87%), 98% (95% CI, 95 to 99%), 36.5 (95% CI, 15.6 to 85.3), and 0.32 (95% CI, 0.15 to 0.70), respectively. The analysis has demonstrated that the diagnostic accuracy of NAA tests is currently insufficient for them to replace culture as a lone diagnostic test. NAA tests may be used in combination with culture due to the advantage of time to result and in scenarios where culture tests are not feasible. Further work to improve NAA tests would benefit from the availability of standardized reference standards and improvements to the methodology.


2020 ◽  
pp. 219256822090681 ◽  
Author(s):  
Muthu Sathish ◽  
Ramakrishnan Eswar

Study Design: Systematic review. Objectives: To assess the methodological quality of systematic reviews and meta-analyses in spine surgery over the past 2 decades. Materials and Methods: We conducted independent and in duplicate systematic review of the published systematic reviews and meta-analyses between 2000 and 2019 from PubMed Central and Cochrane Database pertaining to spine surgery involving surgical intervention. We searched bibliographies to identify additional relevant studies. Methodological quality was evaluated with AMSTAR score and graded with AMSTAR 2 criteria. Results: A total of 96 reviews met the eligibility criteria, with mean AMSTAR score of 7.51 (SD = 1.98). Based on AMSTAR 2 criteria, 13.5% (n = 13) and 18.7% (n = 18) of the studies had high and moderate level of confidence of results, respectively, without any critical flaws. A total of 29.1% (n = 28) of the studies had at least 1 critical flaw and 38.5% (n = 37) of the studies had more than 1 critical flaw, so that their results have low and critically low confidence, respectively. Failure to analyze the conflict of interest of authors of primary studies included in review and lack of list of excluded studies with justification were the most common critical flaw. Regression analysis demonstrated that studies with funding and studies published in recent years were significantly associated with higher methodological quality. Conclusion: Despite improvement in methodological quality of systematic reviews and meta-analyses in spine surgery in current decade, a substantial proportion continue to show critical flaws. With increasing number of review articles in spine surgery, stringent measures must be taken to adhere to methodological quality by following PRISMA and AMSTAR guidelines to attain higher standards of evidence in published literature.


2020 ◽  
pp. 084653712090206 ◽  
Author(s):  
Waleed Abdellatif ◽  
Mahmoud Ahmed Ebada ◽  
Souad Alkanj ◽  
Ahmed Negida ◽  
Nicolas Murray ◽  
...  

Purpose: In this systematic review and meta-analysis, we aimed to investigate the accuracy of dual-energy computed tomography (DECT) in the detection of acute pulmonary embolism (PE). Methods: We searched Medline (via PubMed), EBSCO, Web of Science, Scopus, and the Cochrane Library for relevant published studies. We selected studies assessing the accuracy of DECT in the detection of PE. Quality assessment of bias and applicability was conducted using the Quality of Diagnostic Accuracy Studies-2 tool. Meta-analysis was performed to calculate mean estimates of sensitivity, specificity, positive likelihood ratio (PLR), and negative likelihood ratio (NLR). The summary receiver operating characteristic (sROC) curve was drawn to get the Cochran Q-index and the area under the curve (AUC). Results: Seven studies were included in our systematic review. Of the 182 patients included, 108 patients had PEs. The pooled analysis showed an overall sensitivity and specificity of 88.9% (95% confidence interval [CI]: 81.4%-94.1%) and 94.6% (95% CI: 86.7%-98.5%), respectively. The pooled PLR was 8.186 (95% CI: 3.726-17.986), while the pooled NLR was 0.159 (95% CI: 0.093-0.270). Cochran-Q was 0.8712, and AUC was 0.935 in the sROC curve. Conclusion: Dual-energy computed tomography shows high sensitivity, specificity, and diagnostic accuracy in the detection of acute PE. The high PLR highlights the high clinical importance of DECT as a prevalence-independent, rule-in test. Studies with a larger sample size with standardized reference tests are still needed to increase the statistical power of the study and support these findings.


Author(s):  
Sneha Sethi ◽  
Xiangqun Ju ◽  
Richard M. Logan ◽  
Paul Sambrook ◽  
Robert A. McLaughlin ◽  
...  

Background: Advances in treatment approaches for patients with oral squamous cell carcinoma (OSCC) have been unsuccessful in preventing frequent recurrences and distant metastases, leading to a poor prognosis. Early detection and prevention enable an improved 5-year survival and better prognosis. Confocal Laser Endomicroscopy (CLE) is a non-invasive imaging instrument that could enable an earlier diagnosis and possibly help in reducing unnecessary invasive surgical procedures. Objective: To present an up to date systematic review and meta-analysis assessing the diagnostic accuracy of CLE in diagnosing OSCC. Materials and Methods. PubMed, Scopus, and Web of Science databases were explored up to 30 June 2021, to collect articles concerning the diagnosis of OSCC through CLE. Screening: data extraction and appraisal was done by two reviewers. The quality of the methodology followed by the studies included in this review was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. A random effects model was used for the meta-analysis. Results: Six studies were included, leading to a total number of 361 lesions in 213 patients. The pooled sensitivity and specificity were 95% (95% CI, 92–97%; I2 = 77.5%) and 93% (95% CI, 90–95%; I2 = 68.6%); the pooled positive likelihood ratios and negative likelihood ratios were 10.85 (95% CI, 5.4–21.7; I2 = 55.9%) and 0.08 (95% CI, 0.03–0.2; I2 = 83.5%); and the pooled diagnostic odds ratio was 174.45 (95% CI, 34.51–881.69; I2 = 73.6%). Although risk of bias and heterogeneity is observed, this study validates that CLE may have a noteworthy clinical influence on the diagnosis of OSCC, through its high sensitivity and specificity. Conclusions: This review indicates an exceptionally high sensitivity and specificity of CLE for diagnosing OSCC. Whilst it is a promising diagnostic instrument, the limited number of existing studies and potential risk of bias of included studies does not allow us to draw firm conclusions. A conclusive inference can be drawn when more studies, possibly with homogeneous methodological approach, are performed.


Blood ◽  
2012 ◽  
Vol 120 (20) ◽  
pp. 4160-4167 ◽  
Author(s):  
Adam Cuker ◽  
Phyllis A. Gimotty ◽  
Mark A. Crowther ◽  
Theodore E. Warkentin

Abstract The 4Ts is a pretest clinical scoring system for heparin-induced thrombocytopenia (HIT). Although widely used in clinical practice, its predictive value for HIT in diverse settings and patient populations is unknown. We performed a systematic review and meta-analysis to estimate the predictive value of the 4Ts in patients with suspected HIT. We searched PubMed, Cochrane Database, and ISI Web of Science for studies that included patients with suspected HIT, who were evaluated by both the 4Ts and a reference standard against which the 4Ts could be compared. Quality of eligible studies was assessed by QUADAS-2 criteria. Thirteen studies, collectively involving 3068 patients, fulfilled eligibility criteria. A total of 1712 (55.8%) patients were classified by 4Ts score as having a low probability of HIT. The negative predictive value of a low probability 4Ts score was 0.998 (95% CI, 0.970-1.000) and remained high irrespective of the party responsible for scoring, the prevalence of HIT, or the composition of the study population. The positive predictive value of an intermediate and high probability 4Ts score was 0.14 (0.09-0.22) and 0.64 (0.40-0.82), respectively. A low probability 4Ts score appears to be a robust means of excluding HIT. Patients with intermediate and high probability scores require further evaluation.


BMC Neurology ◽  
2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Fei Han ◽  
Chao Zuo ◽  
Guodong Zheng

Abstract Background The present study aims to evaluate the performance and the clinical applicability of the Recognition of Stroke in the Emergency Department (ROSIER) scale via systematic review and meta-analysis. Methods Electronic databases of Pubmed and Embase were searched between 1st January 2005 (when ROSIER developed) and 8th May 2020. Studies that evaluated the diagnostic accuracy of the ROSIER scale were included. The sensitivity, specificity, diagnostic odds ratio (DOR), and area under the curve (AUC) were combined using a bivariate mixed-effects model. Fagan nomogram was used to evaluate the clinical applicability of the ROSIER scale. Results A total of 14 studies incorporating 15 datasets were included in this meta-analysis. The combined sensitivity, specificity, DOR and AUC were 0.88 [95% confidence interval (CI): 0.83–0.91], 0.66 (95% CI: 0.52–0.77), 13.86 (95% CI, 7.67–25.07) and 0.88 (95% CI, 0.85–0.90), respectively. Given the pre-test probability of 60.0%, Fagan nomogram suggested the post-test probability was increased to 79% when the ROSIER was positive. In comparison, it was decreased to 22% when ROSIER was negative. Subgroup analysis showed that the pooled sensitivity of ROSIER in the European population was higher than that in Asia. In contrast, the pooled specificity was not significantly different between them. Moreover, results also suggested the male-to-female ratio ≤ 1.0 subgroup, prehospital setting subgroup, and other trained medical personnel subgroup had significantly higher sensitivity compared with their counterparts. At the same time, no significant differences were found in the pooled specificity between them. Conclusions ROSIER is a valid scale with high clinical applicability, which has not only good diagnostic accuracy in Europe but also shows excellent performance in Asia. Moreover, the ROSIER scale exhibits good applicability in prehospital settings with other trained medical personnel.


Author(s):  
Yanto Tjang ◽  
Tiara Gracienta ◽  
Ryan Herardi ◽  
Frans Santosa ◽  
Taufiq Pasiak

IntroductionThe rapid transmission of Coronavirus disease 2019 (COVID-19) requires a fast, accurate, and affordable detection method. Despite doubts of its diagnostic accuracy, Rapid Diagnostic Test (RDT) is world-widely used in consideration for its practicality. This systematic review aims to determine the diagnostic accuracy of antibody-based RDT in detecting COVID-19.Material and methodsA literature search was carried out on five journal databases using the PRISMA-P 2015 method. We included all studies published up to February 2021. The risk of bias was evaluated using The Joanna Briggs Institute (JBI) Critical Appraisal Checklist for Diagnostic Test Accuracy Studies. Data regarding peer-review status, study design, tests kit information, immunoglobulin class, target antigen, and the number of samples were extracted and tabulated. We estimated the pooled sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with a 95% confidence interval.ResultsThirty-three studies met the eligibility criteria. The pooled data results showed that the combined detection method of IgM or IgG had the highest sensitivity and NPV, which were 73.41% (95% CI: 72.22-74.57) and 75.34% (95% CI: 74.51-76.16), respectively. The single IgG detection method had the highest specificity and PPV of 96.68% (95% CI: 96.25-97.07) and 95.97% (95% CI: 95.47-96.42%), respectively.ConclusionsAntibody-based RDT is not satisfactory as a primary diagnostic test but has utilities as a screening tool.


10.2196/26167 ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. e26167
Author(s):  
Tien Yun Yang ◽  
Li Huang ◽  
Shwetambara Malwade ◽  
Chien-Yi Hsu ◽  
Yang Ching Chen

Background Atrial fibrillation (AF) is the most common cardiac arrhythmia worldwide. Early diagnosis of AF is crucial for preventing AF-related morbidity, mortality, and economic burden, yet the detection of the disease remains challenging. The 12-lead electrocardiogram (ECG) is the gold standard for the diagnosis of AF. Because of technological advances, ambulatory devices may serve as convenient screening tools for AF. Objective The objective of this review was to investigate the diagnostic accuracy of 2 relatively new technologies used in ambulatory devices, non-12-lead ECG and photoplethysmography (PPG), in detecting AF. We performed a meta-analysis to evaluate the diagnostic accuracy of non-12-lead ECG and PPG compared to the reference standard, 12-lead ECG. We also conducted a subgroup analysis to assess the impact of study design and participant recruitment on diagnostic accuracy. Methods This systematic review and meta-analysis was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. MEDLINE and EMBASE were systematically searched for articles published from January 1, 2015 to January 23, 2021. A bivariate model was used to pool estimates of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and area under the summary receiver operating curve (SROC) as the main diagnostic measures. Study quality was evaluated using the quality assessment of diagnostic accuracy studies (QUADAS-2) tool. Results Our search resulted in 16 studies using either non-12-lead ECG or PPG for detecting AF, comprising 3217 participants and 7623 assessments. The pooled estimates of sensitivity, specificity, PLR, NLR, and diagnostic odds ratio for the detection of AF were 89.7% (95% CI 83.2%-93.9%), 95.7% (95% CI 92.0%-97.7%), 20.64 (95% CI 10.10-42.15), 0.11 (95% CI 0.06-0.19), and 224.75 (95% CI 70.10-720.56), respectively, for the automatic interpretation of non-12-lead ECG measurements and 94.7% (95% CI 93.3%-95.8%), 97.6% (95% CI 94.5%-99.0%), 35.51 (95% CI 18.19-69.31), 0.05 (95% CI 0.04-0.07), and 730.79 (95% CI 309.33-1726.49), respectively, for the automatic interpretation of PPG measurements. Conclusions Both non-12-lead ECG and PPG offered high diagnostic accuracies for AF. Detection employing automatic analysis techniques may serve as a useful preliminary screening tool before administering a gold standard test, which generally requires competent physician analyses. Subgroup analysis indicated variations of sensitivity and specificity between studies that recruited low-risk and high-risk populations, warranting future validity tests in the general population. Trial Registration PROSPERO International Prospective Register of Systematic Reviews CRD42020179937; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=179937


Sign in / Sign up

Export Citation Format

Share Document