Implementation of a computed tomography dose management program across a multinational healthcare organization

Author(s):  
Katia Katsari ◽  
Hugo Pasquier ◽  
Milan Barati ◽  
Pilar Pujadas ◽  
Rowland O. Illing
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shota Ichikawa ◽  
Misaki Hamada ◽  
Hiroyuki Sugimori

AbstractBody weight is an indispensable parameter for determination of contrast medium dose, appropriate drug dosing, or management of radiation dose. However, we cannot always determine the accurate patient body weight at the time of computed tomography (CT) scanning, especially in emergency care. Time-efficient methods to estimate body weight with high accuracy before diagnostic CT scans currently do not exist. In this study, on the basis of 1831 chest and 519 abdominal CT scout images with the corresponding body weights, we developed and evaluated deep-learning models capable of automatically predicting body weight from CT scout images. In the model performance assessment, there were strong correlations between the actual and predicted body weights in both chest (ρ = 0.947, p < 0.001) and abdominal datasets (ρ = 0.869, p < 0.001). The mean absolute errors were 2.75 kg and 4.77 kg for the chest and abdominal datasets, respectively. Our proposed method with deep learning is useful for estimating body weights from CT scout images with clinically acceptable accuracy and potentially could be useful for determining the contrast medium dose and CT dose management in adult patients with unknown body weight.


Author(s):  
Guy Frija ◽  
◽  
John Damilakis ◽  
Graciano Paulo ◽  
Reinhard Loose ◽  
...  

Abstract In recent years, the issue of cumulative effective dose received from recurrent computed tomography examinations has become a subject of increasing concern internationally. Evidence, predominantly from the USA, has shown that a significant number of patients receive a cumulative effective dose of 100 mSv or greater. To obtain a European perspective, EuroSafe Imaging carried out a survey to collect European data on cumulative radiation exposure of patients from recurrent computed tomography examinations. The survey found that a relatively low percentage of patients (0.5%) received a cumulative effective dose equal to or higher than 100 mSv from computed tomography, most of them having an oncological disease. However, there is considerable variation between institutions as these values ranged from 0 to 2.72%, highlighting that local practice or, depending on the institution and its medical focus, local patient conditions are likely to be a significant factor in the levels of cumulative effective dose received, rather than this simply being a global phenomenon. This paper also provides some practical actions to support the management of cumulative effective dose and to refine or improve practice where recurrent examinations are required. These actions are focused around increasing awareness of referring physicians through encouraging local dialogue, actions focused on optimisation where a team approach is critical, better use of modern equipment and the use of Dose Management and Clinical Decision Support Systems together with focused clinical audits. The proper use of cumulative effective dose should be part of training programmes for referrers and practitioners, including what information to give to patients. Patient summary Radiation is used to the benefit of patients in diagnostic procedures such as CT examinations, and in therapeutic procedures like the external radiation treatment for cancer. However, radiation is also known to increase the risk of cancer. To oversee this risk, the cumulative effective dose (CED) received by a patient from imaging procedures over his or her life is important. In this paper, the authors, on behalf of EuroSafe Imaging, report on a survey carried out in Europe that aims to estimate the proportion of patients that undergo CT examinations and are exposed to a CED of more than 100 mSv. At the same time, the survey enquires about and underlines radiologists’ measures and radiology departments’ strategies to limit such exposure. Over the period of 2015–2018, respondents reported that 0.5% (0–2.72%) of patients were exposed to a CED of ≥ 100 mSv from imaging procedures. The background radiation dose in Europe depends on the location, but it is around 2.5 mSv per year. It is obvious that patients with cancer, chronic diseases and trauma run the highest risk of having a high CED. However, even if the number of patients exposed to ≥ 100 mSv is relatively low, it is important to lower this number even further. Measures could consist in using procedures that do not necessitate radiation, using very low dose procedures, being very critical in requiring imaging procedures and increasing awareness about the issue. Key Points • A relatively low percentage of patients (0.5%) received a cumulative effective dose from CT computed tomography equal to or greater than 100 mSv, in Europe, most of them having an oncological disease. • There is a wide range in the number of patients who receive cumulative effective dose equal to or greater than 100 mSv (0–2.72%) and optimisation should be improved. • Increasing the awareness of referring physicians through encouraging local dialogue, concrete actions focused on optimisation and development of dose management systems is suggested.


2012 ◽  
Vol 41 (3-4) ◽  
pp. 154-160 ◽  
Author(s):  
M.M. Rehani

In 1998, the International Commission on Radiological Protection (ICRP) warned that computed tomography (CT) doses were high, and the frequency of usage was likely to increase in view of spiral CT technology that enhances patient convenience and provides high-quality diagnostic information. Two ICRP publications ( Publications 87 and 102) have provided patient dose management recommendations while reviewing the technology and results of optimisations to date, and stimulated interest in patient dose management. The International Atomic Energy Agency, on the other hand, has been instrumental in assessing the state of practice at grassroots level, identifying lacunae in justification and optimisation, providing guidance to counterparts in various countries, and improving practice. The results from approximately 50 less-resourced countries for adult and paediatric CT studies have become available, and some have been published. The concerted efforts and actions by these two international organisations have contributed to better awareness and improvement of patient protection in CT in adults and children in many countries.


2016 ◽  
Vol 32 ◽  
pp. 93-94
Author(s):  
G. Tosi ◽  
M. Profili ◽  
A. Spinillo ◽  
L. Balzarini

2020 ◽  
Vol 125 ◽  
pp. 108900 ◽  
Author(s):  
Gesa H. Poehler ◽  
Babak Alikhani ◽  
Filip Klimes ◽  
Erik F. Hauck ◽  
Kristina I. Ringe ◽  
...  

Author(s):  
Dominik Zinsser ◽  
Roy Marcus ◽  
Ahmed Othman ◽  
Fabian Bamberg ◽  
Konstantin Nikolaou ◽  
...  

Background For years, the number of performed CT examinations has been rising. At the same time, computed tomography became more dose efficient. The aim of this article is to give an overview about the state of the art in dose reduction in CT and to highlight currently available tools in dose management. Method By performing a literature research on Pubmed regarding dose reduction in CT, relevant articles were identified and analyzed. Results and Conclusion Technical innovations with individual adaptation of tube current and voltage as well as iterative image reconstruction enable a considerable dose reduction with preserved image quality. At the same time, dedicated software tools are able to handle huge amounts of data and allow to optimize existing examination protocols. Key points  Citation Format


2018 ◽  
Vol 52 ◽  
pp. 101
Author(s):  
Giovanni Tosi ◽  
Manuel Profili ◽  
Luca Balzarini

2018 ◽  
Vol 48 (1) ◽  
pp. 5-20 ◽  
Author(s):  
Cynthia K. Rigsby ◽  
Sarah E. McKenney ◽  
Kevin D. Hill ◽  
Anjali Chelliah ◽  
Andrew J. Einstein ◽  
...  

Sign in / Sign up