Detection of human serum antibody to encapsulated strains of Staphylococcus aureus by enzyme-linked immunosorbent assay inhibition test*

1998 ◽  
Vol 3 (2) ◽  
pp. 95-101
Author(s):  
Hiroki Ueda ◽  
Kazuhiko Matsushita ◽  
Yoshitoshi Ichiman
1998 ◽  
Vol 26 (01) ◽  
pp. 29-37 ◽  
Author(s):  
Hitoshi Yamashita ◽  
Yoshitoshi Ichiman ◽  
Masami Takahashi ◽  
Kazushi Nishijo

The titer and activity of antibody in rabbits immunized with heat-killed vaccine were assessed with and without moxibustion treatment. Enzyme-linked immunosorbent assay (ELISA) was applied for the detection of immunoglobulins to Smith strain of Staphylococcus aureus. Positive IgM titer of more than 0.4 were observed with this assay against the moxibustion group (P < 0.05). The titer of IgG antibody also increased; however, there was no significant difference between the moxibustion group and the control group. The ELISA inhibition test showed significantly higher protective activity of the sera in the moxibustion group at the 9th week after the first immunization (P < 0.05).


mSphere ◽  
2018 ◽  
Vol 3 (4) ◽  
pp. e00128-18 ◽  
Author(s):  
Danka Pavliakova ◽  
Peter C. Giardina ◽  
Soraya Moghazeh ◽  
Shite Sebastian ◽  
Maya Koster ◽  
...  

ABSTRACT A Luminex-based direct immunoassay (dLIA) platform has been developed to replace the standardized pneumococcal enzyme-linked immunosorbent assay platform. The multiplex dLIA simultaneously measures the concentration of serum immunoglobulin G (IgG) antibodies specific for pneumococcal capsular polysaccharide (PnPS) serotypes 1, 3, 4, 5, 6A, 6B, 7F, 9V, 14, 18C, 19A, 19F, and 23F. The assay uses poly-l-lysine (PLL)-conjugated PnPS, chemically coupled to spectrally distinct Luminex microspheres. Assay validation experiments were performed using residual human serum samples obtained from 13-valent pneumococcal conjugate vaccine (13vPnC) clinical studies. Assay results are expressed as IgG antibody concentrations in micrograms per milliliter using the international reference serum, 007sp. The lower limit of quantitation (LLOQ) for all serotypes covered in the 13-plex dLIA fell within the range of 0.002 to 0.038 µg/ml serum IgG. The difference between the lower limit and upper limit of the assay range was >500-fold for all serotypes, and assay variability was <20% relative standard deviation (RSD) for all serotypes. IgG antibody measurements were shown to be serotype-specific (some cross-reactivity was observed only between the structurally related serotypes 6A and 6B as well as 19A and 19F), and no interference was observed between the serotypes when the assay was performed in the 13-plex format compared to the singleplex assays. The 13-plex dLIA platform developed by Pfizer Inc. generates up to 143 test results in a single 96-well plate and is a suitable replacement of the enzyme-linked immunosorbent assay (ELISA) platform for evaluating vaccine clinical trials. IMPORTANCE The pneumococcal enzyme-linked immunosorbent assay (ELISA) measures IgG antibodies in human serum, and it is an important assay that supports licensure of pneumococcal vaccines. The immune correlate of protection, 0.35 µg/ml of IgG antibodies, was determined by the ELISA method. Pfizer has developed a new Luminex-based assay platform to replace the ELISA. These papers describe the important work of (i) validating the Luminex-based assay and (ii) bridging the immune correlate of protection (0.35 µg/ml IgG) to equivalent values reported by the Luminex platform.


1995 ◽  
Vol 240 (1) ◽  
pp. 1-9 ◽  
Author(s):  
Toshitaka Sato ◽  
Masayoshi Fukasawa ◽  
Makoto Kinoshita ◽  
Hiroyuki Arai ◽  
Takao Saeki ◽  
...  

2012 ◽  
Vol 25 (5) ◽  
pp. 607-619 ◽  
Author(s):  
Thacianna Barreto da Costa ◽  
Natália Gomes de Morais ◽  
Thays Miranda de Almeida ◽  
Maiara Santos Severo ◽  
Célia Maria Machado Barbosa de Castro

OBJETIVO: Avaliar a influência da desnutrição neonatal sobre a produção de Interferon gama, Interleucina-12 e Interleucina-10 em cultura de macrófagos alveolares e linfócitos infectados, in vitro, com Staphylococcus aureus sensível/resistente à meticilina. MÉTODOS: Ratos machos Wistar foram amamentados por mães cuja dieta, durante a lactação, continha 17% de proteína no grupo nutrido e 8% no grupo desnutrido. Após desmame, ambos os grupos receberam a dieta normoproteica. Os macrófagos foram obtidos após traqueostomia, através da coleta do lavado broncoalveolar. Para obtenção dos linfócitos, foi realizado o procedimento cirúrgico de punção cardíaca. Após o isolamento dos diferentes tipos celulares, procedeuse à realização dos estímulos com as cepas de estudo. A dosagem das citocinas foi realizada pelo método de Enzyme-Linked Immunosorbent Assay, a partir de amostras coletadas do sobrenadante das culturas após 24 horas de incubação. RESULTADOS: A desnutrição acarretou diminuição do crescimento ponderal, redução na produção de Interferon gama em cultura de macrófagos alveolares e linfócitos e diminuição na produção de Interleucina-12 em cultura de macrófagos alveolares. Apenas a produção de Interferon gama e Interleucina-10 em cultura de macrófagos alveolares apresentou diferença entre as cepas analisadas, em ambos os grupos estudados. CONCLUSÃO: O modelo de desnutrição neonatal produziu sequela no peso corporal e reduziu a produção de citocinas próinflamatórias (Interleucina-12 e Interferon gama), indicando que esse modelo de desnutrição pode comprometer a resolução de um processo infeccioso. A cepa de Staphylococcus aureus resistente à meticilina estimulou uma maior produção de Interferon gama e Interleucina-10 por macrófagos alveolares, o que sugeriu estimulação imunológica mais intensa, por essa cepa, nesse tipo celular especificamente.


Steroids ◽  
1985 ◽  
Vol 45 (1) ◽  
pp. 31-38 ◽  
Author(s):  
M. Jawed Iqbal ◽  
Alastair Forbes ◽  
Timothy P. Corbishley ◽  
Mark L. Wilkinson ◽  
Roger Williams

Sign in / Sign up

Export Citation Format

Share Document