Clinical results of implant placement in resorbed ridges using simultaneous guided bone regeneration: a multicenter case series

2014 ◽  
Vol 19 (2) ◽  
pp. 553-559 ◽  
Author(s):  
Ioannis Konstantinidis ◽  
Tarun Kumar ◽  
Udatta Kher ◽  
Panagiotis D. Stanitsas ◽  
James E. Hinrichs ◽  
...  
Medicina ◽  
2021 ◽  
Vol 57 (1) ◽  
pp. 60
Author(s):  
Daniele De Santis ◽  
Federico Gelpi ◽  
Giuseppe Verlato ◽  
Umberto Luciano ◽  
Lorena Torroni ◽  
...  

Background and Objective: Guided bone regeneration allows new bone formation in anatomical sites showing defects preventing implant rehabilitation. Material and Methods: The present case series reported the outcomes of five patients treated with customized titanium meshes manufactured with a digital workflow for achieving bone regeneration at future implant sites. A significant gain in both width and thickness was achieved for all patients. Results: From a radiographic point of view (CBTC), satisfactory results were reached both in horizontal and vertical defects. An average horizontal gain of 3.6 ± 0.8 mm and a vertical gain of 5.2 ± 1.1 mm. Conclusions: The findings from this study suggest that customized titanium meshes represent a valid method to pursue guided bone regeneration in horizontal, vertical or combined defects. Particular attention must be paid by the surgeon in the packaging of the flap according to a correct method called the “poncho” technique in order to reduce the most frequent complication that is the exposure of the mesh even if a partial exposure of one mesh does not compromise the final outcome of both the reconstruction and the healing of the implants.


1998 ◽  
Vol 9 (5) ◽  
pp. 303-312 ◽  
Author(s):  
Gérard Brunel ◽  
Edmond Benqué ◽  
Frédéric Elharar ◽  
Catherine Sansac ◽  
Jean François Duffort ◽  
...  

2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
Nikolaos Soldatos ◽  
Georgios E. Romanos ◽  
Michelle Michaiel ◽  
Ali Sajadi ◽  
Nikola Angelov ◽  
...  

Background. The placement of an implant in a previously infected site is an important etiologic factor contributing to implant failure. The aim of this case report is to present the management of retrograde peri-implantitis (RPI) in a first maxillary molar site, 2 years after the implant placement. The RPI was treated using an air-abrasive device, Er,Cr:YSGG laser, and guided bone regeneration (GBR). Case Description. A 65-year-old Caucasian male presented with a draining fistula associated with an implant at tooth #3. Tooth #3 revealed periapical radiolucency two years before the implant placement. Tooth #3 was extracted, and a ridge preservation procedure was performed followed by implant rehabilitation. A periapical radiograph (PA) showed lack of bone density around the implant apex. The site was decontaminated with an air-abrasive device and Er,Cr:YSGG laser, and GBR was performed. The patient was seen every two weeks until suture removal, followed by monthly visits for 12 months. The periapical X-rays, from 6 to 13 months postoperatively, showed increased bone density around the implant apex, with no signs of residual clinical or radiographic pathology and probing depths ≤4 mm. Conclusions. The etiology of RPI in this case was the placement of an implant in a previously infected site. The use of an air-abrasive device, Er,Cr:YSGG, and GBR was utilized to treat this case of RPI. The site was monitored for 13 months, and increased radiographic bone density was noted.


2019 ◽  
Author(s):  
Ye Wu ◽  
Jiaming Chen ◽  
Fuping Xie ◽  
Huanhuan Liu ◽  
Gang Niu ◽  
...  

Abstract Background: The aim of this study was to evaluate the clinical outcome of autotransplantation of mature third molars to fresh molar extraction sockets using 3D replicas. Methods: Ten patients underwent teeth autotransplantation with or without GBR. We observed the mobility, percussion, radiography examination, the probing depth and the masticatory function of the transplanted teeth during two years following up, which were transplanted into fresh molar sockets by using 3D replicas, and GBR when it is necessary. Results: The average extra-oral time of donor tooth had been shortened to 1.65 min when used the 3D replica. Some probing depth of the transplanted tooth were deeper than 3 mm at 4 or 5 weeks temporarily. And one patient felt slight sensitive when chewing with soft food at 4 weeks, then disappeared. The clinical examination of the autotransplantation teeth during one year follow-up showed no sign of failure. Conclusions: The tooth autotransplantation using 3D replica with or without GBR is an effective method which can reduce the extra-oral time of the donor teeth and may result in less failure.


Sign in / Sign up

Export Citation Format

Share Document