scholarly journals Digital Customized Titanium Mesh for Bone Regeneration of Vertical, Horizontal and Combined Defects: A Case Series

Medicina ◽  
2021 ◽  
Vol 57 (1) ◽  
pp. 60
Author(s):  
Daniele De Santis ◽  
Federico Gelpi ◽  
Giuseppe Verlato ◽  
Umberto Luciano ◽  
Lorena Torroni ◽  
...  

Background and Objective: Guided bone regeneration allows new bone formation in anatomical sites showing defects preventing implant rehabilitation. Material and Methods: The present case series reported the outcomes of five patients treated with customized titanium meshes manufactured with a digital workflow for achieving bone regeneration at future implant sites. A significant gain in both width and thickness was achieved for all patients. Results: From a radiographic point of view (CBTC), satisfactory results were reached both in horizontal and vertical defects. An average horizontal gain of 3.6 ± 0.8 mm and a vertical gain of 5.2 ± 1.1 mm. Conclusions: The findings from this study suggest that customized titanium meshes represent a valid method to pursue guided bone regeneration in horizontal, vertical or combined defects. Particular attention must be paid by the surgeon in the packaging of the flap according to a correct method called the “poncho” technique in order to reduce the most frequent complication that is the exposure of the mesh even if a partial exposure of one mesh does not compromise the final outcome of both the reconstruction and the healing of the implants.

2021 ◽  
Vol 12 (3) ◽  
Author(s):  
Nedim Gunes ◽  
Mehmet Gül ◽  
Serkan Dundar ◽  
Gokhan Artas ◽  
Mehmet Ali Kobat ◽  
...  

2004 ◽  
Vol 34 (1) ◽  
pp. 163
Author(s):  
Yun-Ho Lee ◽  
Joon-Bong Park ◽  
Young-Hyuk Kwon ◽  
Yeek Herr ◽  
Chong-Kwan Kim

2019 ◽  
Author(s):  
Ye Wu ◽  
Jiaming Chen ◽  
Fuping Xie ◽  
Huanhuan Liu ◽  
Gang Niu ◽  
...  

Abstract Background: The aim of this study was to evaluate the clinical outcome of autotransplantation of mature third molars to fresh molar extraction sockets using 3D replicas. Methods: Ten patients underwent teeth autotransplantation with or without GBR. We observed the mobility, percussion, radiography examination, the probing depth and the masticatory function of the transplanted teeth during two years following up, which were transplanted into fresh molar sockets by using 3D replicas, and GBR when it is necessary. Results: The average extra-oral time of donor tooth had been shortened to 1.65 min when used the 3D replica. Some probing depth of the transplanted tooth were deeper than 3 mm at 4 or 5 weeks temporarily. And one patient felt slight sensitive when chewing with soft food at 4 weeks, then disappeared. The clinical examination of the autotransplantation teeth during one year follow-up showed no sign of failure. Conclusions: The tooth autotransplantation using 3D replica with or without GBR is an effective method which can reduce the extra-oral time of the donor teeth and may result in less failure.


2015 ◽  
Vol 16 (2) ◽  
pp. 154-162 ◽  
Author(s):  
Danilo Alessio Di Stefano ◽  
Gian Battista Greco ◽  
Lorenzo Cinci ◽  
Laura Pieri

ABSTRACT Aim The present work describes a horizontal ridge augmentation in which a titanium mesh was preshaped by adapting it to a stereolithographic model of the patient's jaw that was fabricated from CT scans. Background Guided bone regeneration (GBR) involves covering the augmentation site with a long-lasting barrier to protect it from the invasion of surrounding soft tissues. Among barriers, titanium meshes may provide a successful outcome, but the intraoperatory time needed to shape them is a disadvantage. Case description The 54-year-old patient, missing the right mandibular second bicuspid, first molar, and second molar, had her atrophic ridge augmented with a 30:70 mixture of autogenous bone and equine, enzyme-deantigenic collagenpreserved bone substitute. Two conical implants were inserted concomitantly in the second bicuspid and first molar positions, and the site was protected with the preshaped mesh. Four months later, the titanium mesh was retrieved, a bone sample was collected, and histological and histomorphometric analyses were performed. Provisional and definitive prostheses were then delivered, and follow-up controls were performed for up to 24 months. Conclusion Preshaping the mesh on a model of the patient's mandible shortened the surgical time and enabled faster mesh placement. Two years after surgery, the implants were perfectly functional, and the bone width was stable over time as shown by radiographic controls. Histological analysis of the bone sample showed the heterologous biomaterial to be biocompatible and undergoing advanced remodeling and replacement with newly formed bone. Clinical significance Preshaping a titanium mesh over a stereolithographic model of the patient's jaw allowed for a significant reduction of the intraoperative time and may be therefore, advisable in routine practice. How to cite this article Di Stefano DA, Greco GB, Cinci L, Pieri L. Horizontal-guided Bone Regeneration using a Titanium Mesh and an Equine Bone Graft. J Contemp Dent Pract 2015;16(2):154-162.


Materials ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 1613
Author(s):  
Eunhye Jang ◽  
Ja-Youn Lee ◽  
Eun-Young Lee ◽  
Hyun Seok

The aim of this study was to evaluate the bone regeneration effect of recombinant human bone morphogenetic protein-2 (rhBMP-2) on a subperiosteal bone graft in a rat model. A subperiosteal space was made on the rat calvarium, and anorganic bovine bone (ABB), ABB/low bone morphogenetic protein (BMP) (5 µg), and ABB/high BMP (50 µg) were grafted as subperiosteal bone grafts. The new bone formation parameters of bone volume (BV), bone mineral density (BMD), trabecular thickness (TbTh), and trabecular spacing (TbSp) were evaluated by microcomputed tomography (µ-CT), and a histomorphometric analysis was performed to evaluate the new bone formation area. The expression of osteogenic markers, such as bone sialoprotein (BSP) and osteocalcin, were evaluated by immunohistochemistry (IHC). The ABB/high BMP group showed significantly higher BV than the ABB/low BMP (p = 0.004) and control groups (p = 0.000) and higher TbTh than the control group (p = 0.000). The ABB/low BMP group showed significantly higher BV, BMD, and TbTh than the control group (p = 0.002, 0.042, and 0.000, respectively). The histomorphometry showed significantly higher bone formation in the ABB/low and high BMP groups than in the control group (p = 0.000). IHC showed a high expression of BSP and osteocalcin in the ABB/low and high BMP groups. Subperiosteal bone grafts with ABB and rhBMP-2 have not been studied. In our study, we confirmed that rhBMP-2 contributes to new bone formation in a subperiosteal bone graft with ABB.


2020 ◽  
Vol 22 (3) ◽  
pp. 342-350
Author(s):  
Alberto Monje ◽  
Ramón Pons ◽  
Andrea Roccuzzo ◽  
Giovanni E. Salvi ◽  
José Nart

Sign in / Sign up

Export Citation Format

Share Document