Effect of different laser types on bonding strength of CAD/CAM-customized zirconia post to root canal dentin: an experimental study

2020 ◽  
Vol 35 (6) ◽  
pp. 1385-1392 ◽  
Author(s):  
Melih Ulgey ◽  
Recai Zan ◽  
Ihsan Hubbezoglu ◽  
Oguzhan Gorler ◽  
Gozde Uysalcan ◽  
...  
2021 ◽  
Author(s):  
Hazem Abouelleil ◽  
Pierre Colon ◽  
Christophe Jeannin ◽  
Alexis Goujat ◽  
Nina Attik ◽  
...  

1996 ◽  
Vol 22 (8) ◽  
pp. 395-398 ◽  
Author(s):  
Ioannis Kolokuris ◽  
Panagiotis Beltes ◽  
Nikolaos Economides ◽  
Ioannis Vlemmas

2018 ◽  
Vol 43 (1) ◽  
Author(s):  
Selen Küçükkaya Eren ◽  
Emel Uzunoğlu ◽  
Banu Sezer ◽  
Zeliha Yılmaz ◽  
İsmail Hakkı Boyacı

2018 ◽  
Vol 82 (2) ◽  
pp. 144-148 ◽  
Author(s):  
H. Simsek ◽  
M. Coruh ◽  
F. Cakici ◽  
F. Fundaoglu Kucukekenci ◽  
T. Gurbuz ◽  
...  

2020 ◽  
Vol 27 (3) ◽  
Author(s):  
Esma Saricam ◽  
◽  
Neslihan Bulak ◽  
Esra Özyurt ◽  
Suat Özcan ◽  
...  

Eliminating microorganisms in the root canal system is important for the success of regenerative endodontics. Objective: This study evaluated the effects of different antibiotic pastes used for regenerative endodontic procedures on dentin microhardness and the push-out bond strength of mineral trioxide aggregate (MTA) to root canal dentin. Methods: Sixty-four maxillary central incisors were instrumented and randomly divided into the following four groups (n = 16) for medicament treatment: triple antibiotic paste, amoxicillin+clavulanic acid, cefaclor, and control (no dressing). After 21 days, two root segments were obtained by sectioning the roots horizontally for push-out and microhardness evaluations. MTA was placed into the root canal of the sectioned segment for the push-out test. In the microhardness evaluation, three indentations were made at 500 and 1,000 μm from the canal lumen. The arithmetic mean was then calculated for each distance. ANOVA with post hoc Scheffe test and t test were used for the statistical analyses. The significance level was set at p < 0.05. Results: No significant difference was found between the groups in terms of push-out bond strength (p > 0.05). Cefaclor and amoxicillin+clavulanic acid reduced the microhardness values of the dentin at 500 μm (p < 0.05) while cefaclor had the lowest value at 1,000 μm (p < 0.05). Conclusion: Cefaclor reduced the microhardness value more than the other medicaments did at a depth of 1,000 μm. The pastes provided similar adhesion of MTA.


Sign in / Sign up

Export Citation Format

Share Document