scholarly journals Combined acquisition of diffusion and T2*-weighted measurements using simultaneous multi-contrast magnetic resonance imaging

Author(s):  
Nora-Josefin Breutigam ◽  
Matthias Günther ◽  
Daniel Christopher Hoinkiss ◽  
Klaus Eickel ◽  
Robert Frost ◽  
...  

Abstract Object In this work, we present a technique called simultaneous multi-contrast imaging (SMC) to acquire multiple contrasts within a single measurement. Simultaneous multi-slice imaging (SMS) shortens scan time by allowing the repetition time (TR) to be reduced for a given number of slices. SMC imaging preserves TR, while combining different scan types into a single acquisition. This technique offers new opportunities in clinical protocols where examination time is a critical factor and multiple image contrasts must be acquired. Materials and methods High-resolution, navigator-corrected, diffusion-weighted imaging was performed simultaneously with T2*-weighted acquisition at 3 T in a phantom and in five healthy subjects using an adapted readout-segmented EPI sequence (rs-EPI). Results The results demonstrated that simultaneous acquisition of two contrasts (here diffusion-weighted imaging and T2*-weighting) with SMC imaging is feasible with robust separation of contrasts and minimal effect on image quality. Discussion The simultaneous acquisition of multiple contrasts reduces the overall examination time and there is an inherent registration between contrasts. By using the results of this study to control saturation effects in SMC, the method enables rapid acquisition of distortion-matched and well-registered diffusion-weighted and T2*-weighted imaging, which could support rapid diagnosis and treatment of acute stroke.

2020 ◽  
Author(s):  
Jia-Suo Jiang ◽  
Liu-Ning Zhu ◽  
Qian Wu ◽  
Yi Sun ◽  
Wei Liu ◽  
...  

Abstract Background To evaluate the feasibility of using simultaneous multi-slice (SMS) readout segmentation of long variable echo-trains (RESOLVE) diffusion-weighted imaging (DWI) to assess parotid gland tumors, compared with conventional RESOLVE DWI Methods From September 2018 to December 2018, 20 consecutive patients with parotid tumors who underwent MRI scan for pre-surgery evaluation were enrolled. SMS-RESOLVE DWI and conventional RESOLVE DWI were scanned with matched imaging parameters, respectively. The scan time of two DWI sequences was recorded. Qualitative (anatomical structure differentiation, lesion display, artifact, and overall image quality) and quantitative (apparent diffusion coefficient, ADC; ratio of signal-to-noise ratio, SNR ratio; ratio of contrast-to-noise ratio, CNR ratio) assessments of image quality were performed, and compared between SMS-RESOLVE DWI and conventional RESOLVE DWI. Paired t-test was used for statistical analyses. Results The scan time was 3 minutes and 41 seconds for SMS-RESOLVE DWI, and 5 minutes and 46 seconds for conventional RESOLVE DWI. SMS-RESOLVE DWI produced similar qualitative image quality with RESOLVE DWI (anatomical structure differentiation, P = 0.164; lesion display, P = 0.193; artifact, P = 0.330; overall image quality, P = 0.083). Meanwhile, there were no significant difference on ADCLesion (P = 0.298), ADCMasseter (P = 0.122), SNR ratio (P = 0.584) and CNR ratio (P = 0.217) between two DWI sequences. Conclusion Compared with conventional RESOLVE DWI, SMS-RESOLVE DWI could provide comparable image quality using markedly reduced scan time. SMS could increase the clinical usability of RESOLVE technique for DWI of parotid gland.


2020 ◽  
Author(s):  
Jia-Suo Jiang ◽  
Liu-Ning Zhu ◽  
Qian Wu ◽  
Yi Sun ◽  
Wei Liu ◽  
...  

Abstract Background To evaluate the feasibility of using simultaneous multi-slice (SMS) readout segmentation of long variable echo-trains (RESOLVE) diffusion-weighted imaging (DWI) to assess parotid gland tumors, compared with conventional RESOLVE DWIMethods From September 2018 to December 2018, 20 consecutive patients with parotid tumors who underwent MRI scan for pre-surgery evaluation were enrolled. SMS-RESOLVE DWI and conventional RESOLVE DWI were scanned with matched imaging parameters, respectively. The scan time of two DWI sequences was recorded. Qualitative (anatomical structure differentiation, lesion display, artifact, and overall image quality) and quantitative (apparent diffusion coefficient, ADC; ratio of signal-to-noise ratio, SNR ratio; ratio of contrast-to-noise ratio, CNR ratio) assessments of image quality were performed, and compared between SMS-RESOLVE DWI and conventional RESOLVE DWI by using Paired t-test. Two-sided P value less than 0.05 indicated significant difference.[l1] Results The scan time was 3 minutes and 41 seconds for SMS-RESOLVE DWI, and 5 minutes and 46 seconds for conventional RESOLVE DWI. SMS-RESOLVE DWI produced similar qualitative image quality with RESOLVE DWI (anatomical structure differentiation, P=0.164; lesion display, P=0.193; artifact, P=0.330; overall image quality, P=0.083). Meanwhile, there were no significant difference on ADCLesion (P=0.298), ADCMasseter (P=0.122), SNR ratio (P=0.584) and CNR ratio (P=0.217) between two DWI sequences. Conclusion Compared with conventional RESOLVE DWI, SMS-RESOLVE DWI could provide comparable image quality using markedly reduced scan time. SMS could increase the clinical usability of RESOLVE technique for DWI of parotid gland.


2014 ◽  
Vol 74 (1) ◽  
pp. 136-149 ◽  
Author(s):  
Robert Frost ◽  
Peter Jezzard ◽  
Gwenaëlle Douaud ◽  
Stuart Clare ◽  
David A. Porter ◽  
...  

2018 ◽  
Vol 2 (6) ◽  
Author(s):  
Peng Jing ◽  
Qiang Zhang

Abstract Objective: To investigate the diagnostic efficacy of preoperative MRI dynamic contrast imaging (DCE-MRI) combined with diffusion-weighted imaging (DWI) in detecting breast cancer.Methods: A retrospective study was performed to compare the results of DCE-MRI combined with DWI in 78 patients with breast cancer who were treated in our hospital between January 20 and December 2018.  Results: After diagnosis, the coincidence rate of diagnosis by DCE-MRI combined with DWI was significantly higher than ultrasound (91.0% versus 55.1%, respectively; P< 0.05). Among the two diagnostic methods, DCE-MRI combined with DWI imaging showed more obvious tumor signals, and the difference was statistically significant (P<0.05).Conclusion: Preoperative application of DCE-MRI combined with DWI can provide a more accurate and effective reference for surgical planning.


2017 ◽  
Vol 58 (12) ◽  
pp. 1500-1510 ◽  
Author(s):  
Hajime Yokota ◽  
Koji Sakai ◽  
Jun Tazoe ◽  
Mariko Goto ◽  
Hiroshi Imai ◽  
...  

Background Simultaneous multi-slice (SMS) imaging is starting to be used in clinical situation, although evidence of clinical feasibility is scanty. Purpose To prospectively assess the clinical feasibility of SMS diffusion-weighted imaging (DWI) and diffusion-tensor imaging (DTI) with blipped-controlled aliasing in parallel imaging for brain lesions. Material and Methods The institutional review board approved this study. This study included 156 hyperintense lesions on DWI from 32 patients. A slice acceleration factor of 2 was applied for SMS scans, which allowed shortening of the scan time by 41.3%. The signal-to-noise ratio (SNR) was calculated for brain tissue of a selected slice. The contrast-to-noise ratio (CNR), apparent diffusion coefficient (ADC), and fractional anisotropy (FA) were calculated in 36 hyperintense lesions with a diameter of three pixels or more. Visual assessment was performed for all 156 lesions. Tractography of the corticospinal tract of 29 patients was evaluated. The number of tracts and averaged tract length were used for quantitative analysis, and visual assessment was evaluated by grading. Results The SMS scan showed no bias and acceptable 95% limits of agreement compared to conventional scans in SNR, CNR, and ADC on Bland–Altman analyses. Only FA of the lesions was higher in the SMS scan by 9% ( P = 0.016), whereas FA of the surrounding tissues was similar. Quantitative analysis of tractography showed similar values. Visual assessment of DWI hyperintense lesions and tractography also resulted in comparable evaluation. Conclusion SMS imaging was clinically feasible for imaging quality and quantitative values compared with conventional DWI and DTI.