Retention Time of Unretained Compound Calculation and Determination of Retention Indices of Some Monosubstituted Benzenes Using a Multiparametric Method in Binary, Ternary and Quaternary Solvent RP-LC Systems

2011 ◽  
Vol 74 (5-6) ◽  
pp. 459-465 ◽  
Author(s):  
Hassina Larbi ◽  
Linda Didaoui ◽  
Yazid Foudil-Cherif ◽  
A. Touabet
1983 ◽  
Vol 267 ◽  
pp. 1-10 ◽  
Author(s):  
J.K. Haken ◽  
J.D. Openshaw ◽  
W.E. Sharples ◽  
B.G. Madden ◽  
F. Vernon

2006 ◽  
Vol 3 (1) ◽  
pp. 60-64 ◽  
Author(s):  
P. Venkata Reddy ◽  
B. Sudha Rani ◽  
G. Srinu Babu ◽  
J. V. L. N. Seshagiri Rao

A reverse phase HPLC method is developed for the determination of Raloxifene in pharmaceutical dosage forms. Chromatography was carried out on an inertsil C18 column using a mixture of acetonitrile and phosphate buffer (30:70 v/v) as the mobile phase at a flow rate of 1 mL/min. Detection was carried out at 290 nm .The retention time of the drug was 10.609 min. The method produced linear responses in the concentration range of 0.5-200 µg/mL of Raloxifene. The method was found to be applicable for determination of the drug in tablets.


INDIAN DRUGS ◽  
2016 ◽  
Vol 53 (11) ◽  
pp. 46-50
Author(s):  
Z. G Khan ◽  
◽  
S. S. Patil ◽  
P. K. Deshmukh ◽  
P. O. Patil

Novel, isocratic reversed phase high performance liquid chromatography method was developed and validated for the determination of enzalutamide (EZA) in bulk drug and pharmaceutical formulation. Efficient separation was achieved on PrincetonSPHER C18 100A, 5μ (250×4.6 mm) under the isocratic mode of elution using acetonitrile: water (80:20) % V/V as a mobile phase pumped in to the column at flow rate 1.0 mL/min. The effluent was monitored at 237.0 nm using UV detector. EZA was eluted in the given mobile phase at retention time (tR) of 3.2 minutes. The standard calibration curve was linear over the concentration range 10 - 60 μg/mL with correlation coefficient 0.997. The method was validated for accuracy, precision, sensitivity, robustness, ruggedness and all the resulting data treated statistically. The system suitability parameters like retention time, theoretical plates, tailing factor, capacity factor were found within the limit.


2013 ◽  
Vol 2013 ◽  
pp. 1-4
Author(s):  
Suying Ma ◽  
Haixia Lv ◽  
Xiaojun Shang

A high performance liquid chromatographic (HPLC) method with UV detector for the determination of dyclonine hydrochloride and a gas chromatography (GC) method with flame ionization detector (FID) for the determination of camphor and menthol in lotion were developed. The developed HPLC method involved using a SinoChoom ODS-BP C18reversed-phase column (5 μm, 4.6 mm × 200 mm) and mobile phase consisting of acetonitrile : water : triethylamine in a ratio of 45 : 55 : 1.0; pH was adjusted to 3.5 with glacial acetic acid. The developed GC method for determination of camphor and menthol involved using an Agilent 19091J-413 capillary chromatographic column (30 m × 320 μm × 0.25 μm). The two methods were validated according to official compendia guidelines. The calibration of dyclonine hydrochloride for HPLC method was linear over the range of 20–200 μg/mL. The retention time was found at 6.0 min for dyclonine hydrochloride. The calibration of camphor and menthol of GC method was linear over the range of 10–2000 μg/mL. The retention time was found at 2.9 min for camphor and 3.05 min for menthol. The proposed HPLC and GC methods were proved to be suitable for the determination of dyclonine hydrochloride, camphor, and menthol in lotion.


Author(s):  
George Joseph ◽  
Asha Varughese ◽  
Ann Daniel

Abstract Background A method has been developed and validated for selective, accurate and precise determination of total proteinogenic amino acids and taurine from Infant Formula and Adult/Pediatric Nutritional Formulas (powders, ready-to-feed liquids, and liquid concentrates). The method was reviewed by the AOAC INTERNATIONAL SPIFAN Expert Review Panel (ERP) during the 133rd AOAC Annual Meeting & Expo on September 7, 2019 in Denver, CO, USA and was recommended to First Action Official MethodsSM status. Objective The method involves protein hydrolysis to amino acids, a simple pre-column derivatisation of amino acids and separation of derivatised amino acids by UHPLC. The quantification of amino acids is performed by multi-point calibration using norvaline as the internal standard. The analytical method is capable of quantitative determination for 22 proteinogenic amino acids, but cannot be used to quantitate tryptophan, which is destroyed during the acid hydrolysis step. Asparagine is determined as aspartic acid and glutamine as glutamic acid. The cystine and cysteine are converted to S-2-carboxyethylthiocysteine (CYSx) and the derivative is separated from the other amino acids. Citrulline which is present in some matrices and it is separated from other amino acids is not included in the method performance evaluation in the single laboratory validation (SLV). Method The proposed method met all the performance requirement limits set in standard method performance requirements (SMPR) 2014.013 for total proteinogenic amino acids and taurine. The correlation coefficient of multi-point calibration was not less than 0.999 for any amino acids at any point in the SLV study confirming the validity of linear dynanic range (LDR) and linearity of the method. The individual amino acids in the chromatogram were identified by absolute retention time and relative retention time (RRT) with respect to the internal standard norvaline. There were no significant (S/N Ratio <10) interferences from the reagents or by-products of derivatisation and targeted matrices. The method demonstrated high selectivity. Result Accuracy of the method was validated using standard reference materials (NIST SRM 1869 and 1849a) and spike recovery studies. The amino acid results in the SRMs were within the ranges of Reference Mass Fraction Values. The accuracy of the method was corroboratively validated by spike recovery studies. The average spike recovery range between 93 to 107% ensure the accuracy of the method for amino acids and compliance to the AOAC SMPR 2014.013. Conclusions Precision data of the method demonstrate that it meets the stakeholder requirements as per the SMPR. The mean RSDr for all the amino acids for 17 matrices selected for the SLV were not more than 4%. The method is very sensitive and the LOQ can go down to approximately ten times lower than the SMPR requirements. The sensitivity of method is a direct reflection of its signal to noise ratio which ensures guaranteed method performance at the lower levels of amino acids in these matrices. Highlights Taurine (aminoethane sulfonic acid) unlike the other amino acids is a beta-sulfonic amino acid that is not used in protein synthesis but is found as a free amino acid in tissues. The acidic functional group (-COOH) in common amino acid is replaced with a sulfonic acid (-SO3H) group in Taurine. The method offers baseline separation of citrulline which is an alpha amino acid generally present in Infant Formula and Adult/Pediatric Nutritional products. The separation of citrulline eliminates the risk of interference of this compound with other amino acids. The method can also separate and quantitate hydroxyproline, an important component of collagen that is often used to quantitate collagen. The method is simple and does not include any proprietary chemicals or instruments and can be performed on any basic reverse phase UHPLC system with UV detection.


Sign in / Sign up

Export Citation Format

Share Document