Plastic loads of elbows with local wall thinning under in-plane bending

2007 ◽  
Vol 145 (1) ◽  
pp. 63-79 ◽  
Author(s):  
Chang-Sik Oh ◽  
Yun-Jae Kim ◽  
Chi-Yong Park
Author(s):  
Izumi Nakamura ◽  
Akihito Otani ◽  
Masaki Shiratori

In order to investigate the influence of degradation on dynamic behavior and the failure mode of piping systems with local wall thinning, shake table tests using 3-D piping system models were conducted. The degradation considered in this study was wall thinning, which would be caused in piping systems due to the effects of aging. The degradation condition induced in the piping system model was 50% full circumferential wall thinning at an elbow. The test model was designed to cause out-of-plane bending moment to the thinned-wall elbow by excitation tests. The model without wall thinning was also used in the excitation test to compare the behavior of the piping system models. These models were excited under same input acceleration until fatigue cracks penetrated or an excessive deformation occurred to the models. Through these tests, the vibration characteristic and the process to failure of degraded piping models were obtained for the out-of-plane bending model. This paper describes the dynamic response and failure behavior of piping systems with wall thinning based on the test results.


Author(s):  
Youssef A. F. Hafiz ◽  
Maher Y. A. Younan ◽  
Hany F. Abdalla

In this paper the shakedown limit load for unreinforced locally thinned wall pipe branch connection is determined using the Simplified Technique. Loadings were considered to be internal pressure, as a steady load, with in-plane bending or with out-of-plane bending applied on the branch, as alternating loads. Two locations of local wall thinning were taken; one was on the run pipe opposite to the branch and other on the branch at the maximum tension stress side of the bending moment applied whether in in-plane or out-of-plane situation. Two Finite Element (FE) limit load models were used to verify the modeling of the pipe branch connection with its local wall thinning. First model results were compared with experimental data taken from the literature, and the second results were compared with numerical models taken also from the literature and also compared with API 579 “Fitness For Service” (FFS), part-five, level-two assessment procedure. First and second comparisons lead to good agreement but for API 579 comparison it was found that it is slightly changing with the depth of the local wall thinning but does not reflect the expected behavior of the limit load as the FEA models showed. For the results of the shakedown limit load analysis, Bree diagrams were constructed to show elastic, shakedown and plastic collapse regions. Then, comparison was made to show the effect of the local wall thinning depth and location on previous limits. Finally, the shakedown results were verified using the elastic-plastic ratcheting analysis of API 579, level three assessment and it showed successfully the shakedown, ratcheting and reversed plasticity regions. This verifications and results can prove that the Simplified Technique can be used as a level-three ratcheting assessment in API 579.


Author(s):  
Kunio Hasegawa ◽  
Yinsheng Li ◽  
Bostjan Bezensek ◽  
Phuong Hoang

Piping items in power plants may experience combined bending and torsion moments during operation. Currently, there is a lack of guidance in the ASME B&PV Code Section XI for combined loading modes including pressure, torsion and bending. Finite element analyses were conducted for 24-inch diameter Schedule 80 pipes with local wall thinning subjected to tensile and compressive stresses. Plastic collapse bending moments were calculated under constant torsion moments. From the calculation results, it can be seen that collapse bending moment for pipes with local thinning subjected to tensile stress is smaller than that subjected to compressive stress. In addition, equivalent moment is defined as the root the sum of the squares of the torsion and bending moments. It is found that the equivalent moments can be approximated with the pure bending moments, when the wall thinning length is equal or less than 7.73R·t for the wall thinning depth of 75% of the nominal thickness, where R is the mean radius and t is the wall thickness of the pipe.


2010 ◽  
Vol 132 (3) ◽  
Author(s):  
Izumi Nakamura ◽  
Akihito Otani ◽  
Masaki Shiratori

Pressurized piping systems used for an extended period may develop degradations such as wall thinning or cracks due to aging. It is important to estimate the effects of degradation on the dynamic behavior and to ascertain the failure modes and remaining strength of the piping systems with degradation through experiments and analyses to ensure the seismic safety of degraded piping systems under destructive seismic events. In order to investigate the influence of degradation on the dynamic behavior and failure modes of piping systems with local wall thinning, shake table tests using 3D piping system models were conducted. About 50% full circumferential wall thinning at elbows was considered in the test. Three types of models were used in the shake table tests. The difference of the models was the applied bending direction to the thinned-wall elbow. The bending direction considered in the tests was either of the in-plane bending, out-of-plane bending, or mixed bending of the in-plane and out-of-plane. These models were excited under the same input acceleration until failure occurred. Through these tests, the vibration characteristic and failure modes of the piping models with wall thinning under seismic load were obtained. The test results showed that the out-of-plane bending is not significant for a sound elbow, but should be considered for a thinned-wall elbow, because the life of the piping models with wall thinning subjected to out-of-plane bending may reduce significantly.


Author(s):  
Kunio Hasegawa ◽  
Yinsheng Li ◽  
Bostjan Bezensek ◽  
Phuong H. Hoang ◽  
Howard J. Rathbun

Piping components in power plants may experience combined bending and torsion moments during operation. There is a lack of guidance for pipe evaluation for pipes with local wall thinning flaws under the combined bending and torsion moments. ASME B&PV Code Section XI Working Group is currently developing fully plastic bending pipe evaluation procedures for pressurized piping components containing local wall thinning subjected to combined torsion and bending moments. Using elastic fully plastic finite element analyses, plastic collapse bending moments under torsions were obtained for 4 (114.3) to 24 (609.6) inch (mm) diameter pipes with various local wall thinning flaw sizes. The objective of this paper is to introduce an equivalent moment, which combines torsion and bending moments by a vector summation, and to establish the applicable range of wall thinning lengths, angles and depths, where the equivalent moments are equal to pure bending moments.


Sign in / Sign up

Export Citation Format

Share Document