Multiwalled carbon nanotubes encapsulated polystyrene: a facile one-step synthesis, electrical and thermal properties

2019 ◽  
Vol 54 (8) ◽  
pp. 6227-6237 ◽  
Author(s):  
Weifang Han ◽  
Wei Song ◽  
Yuxiang Shen ◽  
Chunhua Ge ◽  
Rui Zhang ◽  
...  
2011 ◽  
Vol 8 (7-8) ◽  
pp. 2532-2537 ◽  
Author(s):  
Oskar Michalski ◽  
Brunon Kwiecień ◽  
Karen Khachatryan ◽  
Gohar Khachatryan ◽  
Leszek Stobinski ◽  
...  

2010 ◽  
Vol 2010 ◽  
pp. 1-5 ◽  
Author(s):  
Jing Liu ◽  
Chunli Guo ◽  
Xiaojian Ma ◽  
Changhui Sun ◽  
Fengxia Li ◽  
...  

Multiwalled carbon nanotubes filled with MgO nanorods were synthesized through the reaction of ethanol and Mg powder in the presence ofTiO2at 400C°. X-ray powder diffraction indicated that the sample was composed of graphite and cubic MgO. Transmission electron microscopy studies showed that multi-walled CNTs with the outer diameters of 70–130 nm were filled with discontinuous MgO nanorods whose diameter was in the range of 25–40 nm. The ratios of the band intensities(ID/IG=0.67)in Raman spectrum implied that carbon nanotubes had good crystallinity. The influence of correlative reaction factors on the morphology of the sample and the possible formation mechanism were discussed.


2011 ◽  
Vol 80-81 ◽  
pp. 452-456 ◽  
Author(s):  
Shao Lin Zeng ◽  
Han Kun Zhou ◽  
Ning Gan ◽  
Yu Ting Cao

A disposable, magnetism-controlled, and amperometric immunosensor was fabricated for the determination of C reactive protein (CRP). Firstly, Fe3O4 (core)/Au (shell) nanoparticle (GMP)–coated multiwalled carbon nanotubes (MWCNT–GMP) were prepared. Then, monoclonal antibody (anti-CRP) was immobilized on MWCNT–GMP to prepare MWCNT–GMP/anti-CRP composite magnetic probes. At last, the probes was adsorbed on the surface of N,N''-bis-(2-hydroxy-methylene)-o-phenylenediamine cobalt (CoRb) modified, screen-printed carbon electrodes through external magnetic field.The amount of CRP in the serum sample was determined by one-step immunoassay. When different concentrations of CRP were added into25μL of phosphate-buffered solution (pH7.0) containing10-4M H2O2, the percentage of DPV cathodic peak current decrease (CR%) exhibited a linear relationship with the concentration of CRP in the range of 0.3–100 μg L-1.The detection limit was 0.16 μg L-1(3б).The immunosensor was used to determine CRP in serum samples of patients with heart diseases, and the results were consistent with those of the traditional ELISA method. The proposed amperometric immunosensor was sensitive, rapid, magnetic field–controlled, and disposable; therefore, it could be used to determine even traces of CRP in the blood serums of patients with heart diseases.


Sign in / Sign up

Export Citation Format

Share Document