Microbe-mediate transformation of echinocystic acid by whole cells of filamentous fungus Cunninghamella blakesleana CGMCC 3.910

2018 ◽  
Vol 45 (6) ◽  
pp. 2795-2800
Author(s):  
Shaobin Fu ◽  
Xu Feng ◽  
Di-an Sun
2017 ◽  
Vol 20 (8) ◽  
pp. 719-726
Author(s):  
Yan Song ◽  
Sen-Sen Yan ◽  
Hai-Jun Lin ◽  
Jian-Lin Li ◽  
Xu-Guang Zhai ◽  
...  

2018 ◽  
Vol 33 (13) ◽  
pp. 1842-1848 ◽  
Author(s):  
Shao-Bin Fu ◽  
Xu Feng ◽  
Qing-Feng Meng ◽  
Qing Cai ◽  
Di-An Sun

Author(s):  
S. Edith Taylor ◽  
Patrick Echlin ◽  
May McKoon ◽  
Thomas L. Hayes

Low temperature x-ray microanalysis (LTXM) of solid biological materials has been documented for Lemna minor L. root tips. This discussion will be limited to a demonstration of LTXM for measuring relative elemental distributions of P,S,Cl and K species within whole cells of tobacco leaves.Mature Wisconsin-38 tobacco was grown in the greenhouse at the University of California, Berkeley and picked daily from the mid-stalk position (leaf #9). The tissue was excised from the right of the mid rib and rapidly frozen in liquid nitrogen slush. It was then placed into an Amray biochamber and maintained at 103K. Fracture faces of the tissue were prepared and carbon-coated in the biochamber. The prepared sample was transferred from the biochamber to the Amray 1000A SEM equipped with a cold stage to maintain low temperatures at 103K. Analyses were performed using a tungsten source with accelerating voltages of 17.5 to 20 KV and beam currents from 1-2nA.


Author(s):  
W. E. Rigsby ◽  
D. M. Hinton ◽  
V. J. Hurst ◽  
P. C. McCaskey

Crystalline intracellular inclusions are rarely seen in mammalian tissues and are often difficult to positively identify. Lymph node and liver tissue samples were obtained from two cows which had been rejected at the slaughter house due to the abnormal appearance of these organs in the animals. The samples were fixed in formaldehyde and some of the fixed material was embedded in paraffin. Examination of the paraffin sections with polarized light microscopy revealed the presence of numerous crystals in both hepatic and lymph tissue sections. Tissue sections were then deparaffinized in xylene, mounted, carbon coated, and examined in a Phillips 505T SEM equipped with a Tracor Northern X-ray Energy Dispersive Spectroscopy (EDS) system. Crystals were obscured by cellular components and membranes so that EDS spectra were only obtainable from whole cells. Tissue samples which had been fixed but not paraffin-embedded were dehydrated, embedded in Spurrs plastic, and sectioned.


Author(s):  
B.A. Hamkalo ◽  
S. Narayanswami ◽  
A.P. Kausch

The availability of nonradioactive methods to label nucleic acids an the resultant rapid and greater sensitivity of detection has catapulted the technique of in situ hybridization to become the method of choice to locate of specific DNA and RNA sequences on chromosomes and in whole cells in cytological preparations in many areas of biology. It is being applied to problems of fundamental interest to basic cell and molecular biologists such as the organization of the interphase nucleus in the context of putative functional domains; it is making major contributions to genome mapping efforts; and it is being applied to the analysis of clinical specimens. Although fluorescence detection of nucleic acid hybrids is routinely used, certain questions require greater resolution. For example, very closely linked sequences may not be separable using fluorescence; the precise location of sequences with respect to chromosome structures may be below the resolution of light microscopy(LM); and the relative positions of sequences on very small chromosomes may not be feasible.


Author(s):  
B. Thompson ◽  
N. Sculov ◽  
R.E. Crang

The use of co-polymerized glutaraldehyde-carbohydrazide (GACH) was proposed for specimen preparation in scanning electron microscopy (SEM) as a means of avoiding dehydration in organic solvents, and to provide dimensionally stable biological specimens through a process of air-drying. It has been assumed that shrinkage of specimens prepared by the GACH technique should be less than that of conventionally-prepared material by critical point drying (CPD). In a previous study, Bell has reported significant shrinkage of whole cells for SEM. This report compares cell shrinkage in GACH and CPD preparations.Fibroblasts from newborn rats were grown on collagen-coated glass cover-slips (with alpha numeric grids etched onto the surface of the coverslips) in Eagle's minimum essential medium + 10% fetal calf serum for 7 d. (3). Using an inverted microscope with phase-contrast optics, micrographs were taken of the cultures in their live state and 1 h. after fixation with 2.5% glutaraldehyde in Dulbecco's phosphate buffered saline (Figs. 1 and 3).


Author(s):  
Jean-Paul Revel

In the last 50+ years the electron microscope and allied instruments have led the way as means to acquire spatially resolved information about very small objects. For the material scientist and the biologist both, imaging using the information derived from the interaction of electrons with the objects of their concern, has had limitations. Material scientists have been handicapped by the fact that their samples are often too thick for penetration without using million volt instruments. Biologists have been handicapped both by the problem of contrast since most biological objects are composed of elements of low Z, and also by the requirement that sample be placed in high vacuum. Cells consist of 90% water, so elaborate precautions have to be taken to remove the water without losing the structure altogether. We are now poised to make another leap forwards because of the development of scanned probe microscopies, particularly the Atomic Force Microscope (AFM). The scanning probe instruments permit resolutions that electron microscopists still work very hard to achieve, if they have reached it yet. Probably the most interesting feature of the AFM technology, for the biologist in any case, is that it has opened the dream of high resolution in an aqueous environment. There are few restrictions on where the instrument can be used. AFMs can be made to work in high vacuum, allowing the material scientist to avoid contamination. The biologist can be made happy as well. The tips used for detection are made of silicon nitride,(Si3N4), and are essentially unaffected by exposure to physiological saline (about which more below). So here is an instrument which can look at living whole cells and at atoms as well.


1982 ◽  
Vol 48 (02) ◽  
pp. 211-216 ◽  
Author(s):  
V M Haver ◽  
A R L Gear

SummaryPlatelet heterogeneity has been studied with a technique called functional fractionation which employs gentle centrifugation to yield subpopulations (“reactive” and “less-reactive” platelets) after exposure to small doses of aggregating agent. Aggregation kinetics of the different platelet populations were investigated by quenched-flow aggregometry. The large, “reactive” platelets were more sensitive to ADP (Ka = 1.74 μM) than the smaller “less-reactive” platelets (Ka = 4.08 μM). However, their maximal rate of aggregation (Vmax, % of platelets aggregating per sec) of 23.3 was significantly lower than the “less-reactive” platelets (Vmax = 34.7). The “reactive” platelets had a 2.2 fold higher level of cyclic AMP.Platelet glycoproteins were labeled using the neuraminidase-galactose oxidase – [H3]-NaBH4 technique. When platelets were labeled after reversible aggregation, the “reactive” platelets showed a two-fold decrease in labeling efficiency (versus control platelets). However, examination of whole cells or membrane preparations from reversibly aggregated platelets revealed no significant difference in Coomassie or PAS (Schiff) staining.These results suggest that the large, “reactive” platelets are more sensitive to ADP but are not hyperaggregable in a kinetic sense. Reversible aggregation may cause a re-orientation of membrane glycoproteins that is apparently not characterized by a major loss of glycoprotein material.


Sign in / Sign up

Export Citation Format

Share Document