Transmission electron microscope specimen preparation of Zn powders using the focused ion beam lift-out technique

1998 ◽  
Vol 29 (9) ◽  
pp. 2399-2406 ◽  
Author(s):  
B. I. Prenitzer ◽  
L. A. Giannuzzi ◽  
K. Newman ◽  
S. R. Brown ◽  
R. B. Irwin ◽  
...  
1998 ◽  
Vol 4 (S2) ◽  
pp. 856-857
Author(s):  
David M. Longo ◽  
James M. Howe ◽  
William C. Johnson

The focused ion beam (FIB) has become an indispensable tool for a variety of applications in materials science, including that of specimen preparation for the transmission electron microscope (TEM). Several FIB specimen preparation techniques have been developed, but some problems result when FIB specimens are analyzed in the TEM. One of these is X-ray fluorescence from bulk material surrounding the thin membrane in FIB-prepared samples. This paper reports on a new FIB specimen preparation method which was devised for the reduction of X-ray fluorescence during energy dispersive X-ray spectroscopy (EDS) in the TEM.Figure 1 shows three membrane geometries that were investigated in this study on a single-crystal Si substrate with a RF sputter-deposited 50 nm Ni film. Membrane 1 is the most commonly reported geometry in the literature, with an approximately 20 urn wide trench and a membrane having a single wedge with a 1.5° incline.


Author(s):  
H. J. Bender ◽  
R. A. Donaton

Abstract The characteristics of an organic low-k dielectric during investigation by focused ion beam (FIB) are discussed for the different FIB application modes: cross-section imaging, specimen preparation for transmission electron microscopy, and via milling for device modification. It is shown that the material is more stable under the ion beam than under the electron beam in the scanning electron microscope (SEM) or in the transmission electron microscope (TEM). The milling of the material by H2O vapor assistance is strongly enhanced. Also by applying XeF2 etching an enhanced milling rate can be obtained so that both the polymer layer and the intermediate oxides can be etched in a single step.


2000 ◽  
Vol 6 (5) ◽  
pp. 452-462 ◽  
Author(s):  
Julie M. Cairney ◽  
Robert D. Smith ◽  
Paul R. Munroe

AbstractTransmission electron microscope samples of two types of metal matrix composites were prepared using both traditional thinning methods and the more novel focused ion beam miller. Electropolishing methods were able to produce, very rapidly, thin foils where the matrix was electron transparent, but the ceramic reinforcement particles remained unthinned. Thus, it was not possible in these foils to study either the matrix-reinforcement interface or the microstructure of the reinforcement particles themselves. In contrast, both phases in the composites prepared using the focused ion beam miller thinned uniformly. The interfaces in these materials were clearly visible and the ceramic reinforcement was electron transparent. However, microstructural artifacts associated with ion beam damage were also observed. The extent of these artifacts and methods of minimizing their effect were dependent on both the materials and the milling conditions used.


2011 ◽  
Vol 17 (6) ◽  
pp. 889-895 ◽  
Author(s):  
Lynne M. Gignac ◽  
Surbhi Mittal ◽  
Sarunya Bangsaruntip ◽  
Guy M. Cohen ◽  
Jeffrey W. Sleight

AbstractThe ability to prepare multiple cross-section transmission electron microscope (XTEM) samples from one XTEM sample of specific sub-10 nm features was demonstrated. Sub-10 nm diameter Si nanowire (NW) devices were initially cross-sectioned using a dual-beam focused ion beam system in a direction running parallel to the device channel. From this XTEM sample, both low- and high-resolution transmission electron microscope (TEM) images were obtained from six separate, specific site Si NW devices. The XTEM sample was then re-sectioned in four separate locations in a direction perpendicular to the device channel: 90° from the original XTEM sample direction. Three of the four XTEM samples were successfully sectioned in the gate region of the device. From these three samples, low- and high-resolution TEM images of the Si NW were taken and measurements of the NW diameters were obtained. This technique demonstrated the ability to obtain high-resolution TEM images in directions 90° from one another of multiple, specific sub-10 nm features that were spaced 1.1 μm apart.


2006 ◽  
Vol 961 ◽  
Author(s):  
Hyunjung Kim ◽  
Sikyung Choi ◽  
Sukhoon Kang ◽  
Kyuhwan Oh ◽  
Soonyong Kweon

ABSTRACTRecently, the development of information technology (IT) increases the demands of memory devices. Phase change random access memory (PRAM), based on the reversible phase change of the chalcogenide alloy, Ge2Sb2Te5, is widely regarded as a favourite candidate for the next generation memory. Because of PRAM has a simple cell structure with high scalability; it is non-volatile, has a relatively high read/write operation speed (Â50ns). The PRAM operation relies on the fact that chalcogenide-based materials can be reversible switched from an amorphous phase to a crystalline state by an external electrical current. It is important to study the electrical property with set/reset cycles, since film thickness shrinkage occurs with the phase transition.In this work, we fabricated the 100nm amorphous Ge2Sb2Te5 thin film on TiN/Ti/Si substrate using dc-magnetron sputtering. The 50X50§2 isolated Ge2Sb2Te5 cell was lithographed by the lift-off pattern and wet etching. And TiN top electrode was deposited using pattern align process at room temperature after the SiO2 insulator CMP. Phase transition behavior with the set/reset cycle was observed using I-V measurement and transmission electron microscope (TEM) on isolated Ge2Sb2Te5 cell. The set/reset programming was operated using tungsten SPM tip which was fabricated using focused ion beam (FIB) lithography. I-V curve which was observed by the I-V probe clearly showed that the phase transition was occurred by applying the electric field through the I-V probe. The resistivity difference between amorphous and crystal state was more than 102. After the phase transition, it was also demonstrated with transmission electron microscope (TEM) analysis. For the preparation of TEM specimen of the amorphous and crystalline cell, focused ion beam (FIB) lithography was adopted.


2003 ◽  
Vol 210 (3-4) ◽  
pp. 399-410 ◽  
Author(s):  
Larissa F. Dobrzhinetskaya ◽  
Harry W. Green ◽  
Matthew Weschler ◽  
Mark Darus ◽  
Young-Chung Wang ◽  
...  