Rapid rule-out of suspected acute coronary syndrome in the Emergency Department by high-sensitivity cardiac troponin T levels at presentation

2018 ◽  
Vol 14 (3) ◽  
pp. 403-410 ◽  
Author(s):  
Andrea Fabbri ◽  
Cristina Bachetti ◽  
Filippo Ottani ◽  
Alice Morelli ◽  
Barbara Benazzi ◽  
...  
2020 ◽  
Vol 9 (11) ◽  
pp. 3627
Author(s):  
Hanna Waldsperger ◽  
Moritz Biener ◽  
Kiril M. Stoyanov ◽  
Mehrshad Vafaie ◽  
Hugo A. Katus ◽  
...  

Aims: We aimed to assess the prognostic role of copeptin in patients presenting to the emergency department with acute symptoms and increased high-sensitivity cardiac troponin T. Methods: A total of 3890 patients presenting with acute symptoms to the emergency department of Heidelberg University Hospital were assessed for increased hs-cTnT (>14 ng/L) from three cohorts: the Heidelberg Acute Coronary Syndrome (ACS) Registry (n = 2477), the BIOPS Registry (n = 320), and the ACS OMICS Registry (n = 1093). In a pooled analysis, 1956 patients remained, comprising of 1600 patients with ACS and 356 patients with non-ACS. Results: Median follow-up was 1468 days in the ACS cohort and 709 days in the non-ACS cohort. Elevated copeptin levels (>10 pmol/L) were found in 1174 patients (60.0%) in the entire cohort (58.1% in ACS and 68.5% in non-ACS, respectively) and mortality rates were significantly higher than in patients with normal copeptin levels (29.0% vs. 10.7%, p < 0.001). In a multivariate Cox regression, elevated copeptin was independently associated with all-cause death in the ACS (HR = 1.7, 1.3–2.3, p = 0.002) and non-ACS cohort (HR = 2.7, 1.4–5.0, p = 0.0018). Conclusion: Copeptin may aid in identifying patients at risk for adverse outcomes in patients with increased levels of hs-cTnT in ACS patients and in non-ACS conditions.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
T R Johannessen ◽  
D Atar ◽  
S Halvorsen ◽  
A C Larstorp ◽  
I Mdala ◽  
...  

Abstract Background The majority of patients with chest pain in Norway initially present to the primary health care system, which serves to triage them to the specialist health care services including hospitals. In some emergency primary care institutions, patients who are not hospitalised directly undergo further diagnostic testing to rule out acute myocardial infarction (AMI). Purpose Several studies have shown the advantage of using high-sensitivity assays for fast interpretation of cardiac troponins. The majority of these studies included patient populations from hospital emergency departments. In contrast, we aimed to investigate whether the 1-hour algorithm for high-sensitivity cardiac troponin T (hs-cTnT) is safe and useful for implementation in a primary care emergency setting where the patients have a much lower pre-test probability for an acute coronary syndrome. Methods In this prospective cohort study, we included 1672 patients with acute non-specific chest pain from November 2016 to October 2018 at a primary care emergency outpatient clinic in Norway. Serial hs-cTnT samples were analysed after 0, 1 and 4 hours on the Cobas 8000 e602 analyzer. We divided the results into one of three groups (rule-out, rule-in, or further observation), according to the 0/1-hour algorithm for hs-cTn from the current ESC guidelines on non-ST-elevation myocardial infarction. In the rule-out group, the 0/1-hour results were compared to the standard 4-hour hs-cTnT. Final hospital diagnoses were collected as a gold standard for the patients in the rule-in group. Results A total of 44 (2.6%) of 1672 patients were diagnosed with AMI. By applying the algorithm, 1274 (76.2%) patients were assigned to the rule-out group. One of the rule-out patients had a significant increase in hs-cTnT in the 4-hour sample. This results in a sensitivity for AMI of 97.7% (95% confidence interval [CI] 88.0–99.9) and negative predictive value of 99.9% (95% CI 99.6–100.0). There were 50 (3.0%) patients in the rule-in group, amongst whom 35 had a verified AMI. This gives a specificity for AMI of 99.1% (95% CI 98.5–99.5) and a positive predictive value at 70.0% (95% CI 55.4–82.1). Among the 348 (20.8%) patients assigned to further observation, eight patients had an AMI. The 15 rule-in patients who did not have an AMI, had other acute illnesses that required further diagnostic work-up at the hospital. Conclusions With a negative predictive value at 99.9%, the 1-hour algorithm for hs-cTnT seems safe and applicable for a faster assessment of patients with non-specific chest pain in a primary care emergency setting. Prehospital implementation of this algorithm may reduce the need for hospitalisation of these patients and hence may probably lower the costs. ClinicalTrial.gov identifier: NCT02983123 Acknowledgement/Funding Norwegian Research Fund for General Practice, The Norwegian Physicians' Association Fund for Quality Improvement and Patient Safety


2020 ◽  
Vol 75 (8) ◽  
pp. 985-987 ◽  
Author(s):  
Andrew R. Chapman ◽  
Dennis Sandeman ◽  
Amy V. Ferry ◽  
Stacey Stewart ◽  
Fiona E. Strachan ◽  
...  

2010 ◽  
Vol 56 (4) ◽  
pp. 642-650 ◽  
Author(s):  
Evangelos Giannitsis ◽  
Meike Becker ◽  
Kerstin Kurz ◽  
Georg Hess ◽  
Dietmar Zdunek ◽  
...  

Abstract Background: We sought to determine the diagnostic performance of the new high-sensitivity cardiac troponin T (hs-cTnT) assay for early detection of non–ST-segment myocardial infarction (NSTEMI) in patients with acute coronary syndrome. Methods: We enrolled patients with retrospectively confirmed unstable angina or NSTEMI and an initially negative cTnT concentration and compared the performance of baseline concentrations and serial changes in concentration within 3 and 6 h. Percentage change criteria included ≥20% δ change and ROC-optimized value. Results: Based on the standard fourth-generation cTnT result of ≥0.03 μg/L, an evolving NSTEMI was diagnosed in 26 patients, and 31 patients were classified as having unstable angina. With the use of the hs-cTnT assay at the 99th-percentile cutoff, the percentage of NSTEMI cases detected increased gradually from 61.5% on presentation to 100% within 6 h, and the overall number of MI diagnoses increased by 34.6% (35 vs 26 cases). A δ change ≥20% or ≥ROC-optimized value of &gt;117% within 3 h or ≥243% within 6 h yielded a specificity of 100% at sensitivities between 69% and 76%. The standard cTnT at the 99th percentile was less sensitive than hs-cTnT for early diagnosis of MI on presentation, and follow-up samples obtained within the initial 3 h demonstrated very low specificity of cTnT compared with hs-cTnT. Conclusions: The high-sensitivity cTnT assay increases the number of NSTEMI diagnoses and enables earlier detection of evolving NSTEMI. A doubling of the hs-cTnT concentration within 3 h in the presence of a second concentration ≥99th percentile is associated with a positive predictive value of 100% and a negative predictive value of 88%.


Sign in / Sign up

Export Citation Format

Share Document