scholarly journals Graft patency at 3 months after off- and on-pump coronary bypass surgery: a randomized trial

2019 ◽  
Vol 36 (2) ◽  
pp. 93-104 ◽  
Author(s):  
Lokeswara Rao Sajja ◽  
Kunal Sarkar ◽  
Gopichand Mannam ◽  
Venkata Krishna Kumar Kodali ◽  
Chandrasekar Padmanabhan ◽  
...  

Abstract Purpose Coronary artery bypass grafting (CABG) is performed either with the aid of cardiopulmonary bypass (on-pump) or without cardiopulmonary bypass (off-pump). There is a scarcity of angiographic data to support the non-inferiority of off-pump technique to on-pump technique. The objective of this study is to ascertain the non-inferiority of off-pump CABG when compared to on-pump CABG in terms of angiographically assessed graft patency at 3 months. Methods A total of 320 patients with multivessel coronary artery disease were enrolled in a multicenter prospective randomized trial either to on-pump CABG (n = 162) or off-pump CABG (n = 158) between March 2016 through March 2017. Graft patency was evaluated by using either multidetector computerized tomographic angiography or conventional coronary angiography at 3 months. The major adverse cardiac and cardiovascular events (MACCE) were also analyzed at 3 months. Results The median number of grafts per patient in off-pump was 3.00 (Q1:3.00 and Q3:4.00) vs on-pump 4.00 (Q1:3.00 to Q3:4.00), and the mean number of grafts per patient was lower in the off-pump CABG at 3.45 ± 0.75 vs 3.64 ± 0.70 in the on-pump CABG (p = 0.01). There was no significant difference in mortality at 3 months between the off-pump (0.63%) and on-pump groups (1.85%) with p value of 0.62. The cumulative combined MACCE showed significant difference between off-pump group (0.63%) and on-pump group (5.55%), p = 0.01. Follow-up angiograms were done in 239 (75%) patients with 120 off-pump and 119 in the on-pump group. The analysis was also done regarding graft patency in a graded manner—when analysis of A (excellent) grafts vs B (stenosed) grafts and O (occluded) grafts were made, there was no statistically significant difference in overall graft patency at 3 months between on-pump [376 /429 grafts (87.6%)] and off-pump [366 /420 grafts (87.1%)] groups (p = 0.82). The patency rates were similar among bypass conduits (left internal thoracic artery (ITA) in off-pump (91.4%) vs on-pump (92.9%) p = 0.66, right ITA in off-pump (82.1%) vs on-pump (81.8%) p = 0.97, radial artery in off-pump (84.4%) vs on-pump (82.6%) p = 0.81; saphenous vein in off-pump (85.8%) vs on-pump (86.3%), p = 0.86 and among 3 coronary territories. Conclusions Off-pump CABG is non-inferior to on-pump CABG in terms of overall graft patency at 3 months and was associated with a fewer combined cumulative MACCE compared to on-pump CABG.

KYAMC Journal ◽  
2017 ◽  
Vol 4 (1) ◽  
pp. 341-347
Author(s):  
Md Masumul Gani Chowdhury ◽  
Md Zakaria ◽  
NAK Ahsan

Background: Cardiopulmonary bypass has been implicated in causing poor pulmonary gas exchange postoperatively in patients undergoing coronary artery bypass graft (CABG). This nonrandomized prospective study was conducted to determine whether patients undergoing off-pump CABG and thereby avoiding cardiopulmonary bypass will have improved pulmonary functions postoperatively.Method: Sixty patients undergoing elective CABG in the National Institute of Cardiovascular Diseases (NICVD), Dhaka between July 2005 and June 2006 were consecutively selected in the study. Sample was divided into two groups: Group A- off-pump CABG and Group-B on-pump CABG. The test statistics used to analyze the data were descriptive statistics as Chi-square (×2) and Student's t-test.Results: Preoperative arterial blood gas (ABG) analysis showed no significant difference. ABG immediately at ICU on FiO2 1 revealed significantly better gas exchange in off-pump group (PaO2: 296.5±32.4 torr vs 234.8±10.7 torr, p<0.001; D(A-a)O2: 378.5±27.3 torr vs 439.2±10.3 torr, p<0.001; PaCO2: 38.5±3.8 torr vs 40.1±1.8 torr, p=0.045). ABG on 3rd postoperative day revealed no significant difference between the two groups. Ventilation time in off-pump group was significantly less than in on-pump group (10.5±2.8 hours vs 14.8±3.7 hours, p<0.001). For ICU stay, there was no significant difference. Postoperative spirometry at 3 month and pulmonary complications within 3 months were not different between groups.Conclusion: off-pump CABG group yielded better gas exchange and earlier extubation than on-pump CABG group.KYAMC Journal Vol. 4, No.-1, July 2013, Page 341-347


Circulation ◽  
2008 ◽  
Vol 118 (suppl_18) ◽  
Author(s):  
Khalil Fattouch ◽  
Giuseppe Runza ◽  
Roberta Sampognaro ◽  
Massimo Midiri ◽  
Giovanni Ruvolo

Off-pump coronary artery bypass grafting is better than on-pump in patients with STEMI underwent surgery within 2 days from onset of symptoms. Surgeons may be reluctant to use OPCAB due to concerns about completeness of myocardial revascularization and graft patency. The aim of this study was to assess long-term clinical outcomes and graft patency in this kind of patients. Participants in two previous randomized studies performed in our institution including 207 STEMI patients underwent emergent or urgent CABG within 48 hours from onset of symptoms were followed after surgery to assess graft patency and major adverse cardiac-related events (MACE). There were 145 patients operated in on-pump and 62 patients in off-pump. Patency was assessed by multidetector computed tomography coronary angiography (MDCTA) with a 64-slice scanner. Two blinded observers classified proximal, body and distal segments of each graft as occluded or not, or grade of stenosis. Clinical follow-up was obtained by our cardiologists. Overall early mortality was 5.3% (11 pts). Percentage of early mortality were 6.7% and 1.6% in on- and off-pump group respectively (p<0.05). Follow-up was obtained in all 196 survivors and was 100% complete. Overall late deaths occurred in 14 patients (7%) without statistical significant difference between both groups; of the remaining 182, 168 (92.3 %) had MDCTA scans (108 pts in on-pump vs 60 pts in off-pump). Patency was studied in 335 grafts in on-pump and 156 grafts in off-pump. Mean duration of follow-up were 38±16 months and 37±14 months for on- and off-pump, respectively. Overall, 449/491 (91.5%) of grafts were patent. Percentages of overall grafts classified as patent were similar in on-pump and off-pump groups (307/335, 91.6% and 142/156, 91% respectively) and for arterial and vein grafts separately. There were also no differences between groups in the incidence of late death and MACE. Long term graft patency and MACE are similar with on-pump vs off-pump CABG in high risk STEMI patients when operation was performed by experienced surgeons. Supported by this results and by low early mortality in off-pump group, we suggests strictly the use of off-pump CABG in this type of patients.


Author(s):  
Shahzad G. Raja ◽  
Jaymin Shah ◽  
Manoraj Navaratnarajah ◽  
Fouad Amin ◽  
Mohamed Amrani

Objective Octogenarians, as the fastest growing stratum of the population and with the highest prevalence of coronary artery disease, are being increasingly referred for coronary artery bypass grafting (CABG). The general perception is that the presence of comorbidities and the propensity for neurological injury expose them to a higher risk for mortality and morbidity after conventional on-pump CABG, and therefore, off-pump CABG should be preferentially offered to octogenarians to improve outcomes. This study evaluates the in-hospital outcomes and predictors of mortality and stroke in octogenarians undergoing on- and off-pump CABG at our institution. Methods From January 2000 to December 2010, a total of 290 octogenarians underwent off-pump (n = 217) and on-pump (n = 73) CABG. Their data were prospectively entered into the cardiac surgery database (Patients Analysis & Tracking System; Dendrite Clinical Systems, Ltd, Oxford, England, United Kingdom) and analyzed retrospectively. Outcome measures included in-hospital mortality, major complications, and length of stay. Multivariate analysis was performed to identify predictors of combined outcome of in-hospital mortality and stroke. Results The mean ± SD age of the patients was 82 ± 2.0 years. Preoperative demographics were similar for the on-pump and off-pump groups. The patients who underwent off-pump CABG had a lower number of distal anastomoses performed compared with the patients who underwent on-pump CABG [mean difference, 0.2; 95% confidence interval (CI), 0.02–0.4; P = 0.03]. However, the ratio of grafts (received/needed) was the same in both groups. In-hospital mortality for the entire cohort was 7.2%, with no significant difference between the groups for death (6.0% vs 11.0%; P = 0.08), stroke (2.8% vs 2.8%; P = 1.0), other major complications, and length of hospital stay. Independent predictors of combined outcome identified from the multiple logistic model included heart failure [odds ratio (OR), 4.4; 95% CI, 1.5–13.0; P = 0.008], diabetes (OR, 2.6; 95% CI, 1.0–6.0; P = 0.046), nitrate infusion (OR, 2.9; 95% CI, 1.1–8.0; P = 0.04), postoperative renal failure requiring hemofiltration (OR, 8.6; 95% CI, 3.5–21.1; P < 0.001), and postoperative ventricular arrhythmias (OR, 7.3; 95% CI, 1.9–27.8; P = 0.009). Conclusions Both on-pump and off-pump CABG are reasonable revascularization strategies in octogenarians. Careful patient selection and individualized treatment decisions can minimize postoperative mortality and morbidity in octogenarians undergoing on- and off-pump CABG.


2018 ◽  
Vol 66 (06) ◽  
pp. 464-469 ◽  
Author(s):  
Michael Zacher ◽  
Jochen Boergermann ◽  
Utz Kappert ◽  
Michael Hilker ◽  
Gloria Färber ◽  
...  

Background Coronary artery bypass grafting (CABG) without cardiopulmonary bypass (off-pump CABG) may reduce severe adverse events including stroke. Methods In the German Off-Pump Coronary Artery Bypass Grafting in Elderly patients trial, the rate of major adverse cardiovascular events was compared in 2,394 elderly (≥ 75 years) patients undergoing CABG with (on-pump) or without (off-pump) cardiopulmonary bypass. This exploratory post-hoc analysis investigated the impact of surgical aortic manipulation on the rate of stroke. Results There was no significant difference in the rate of stroke within 30 days after surgery between both groups (off-pump: 2.2%; on-pump: 2.7%; odds ratio [OR]: 0.83 [0.5–1.38]; p = 0.47). Within the off-pump group, different degrees of aortic manipulation did not lead to significant different stroke rates (tangential clamping: 2.3%; OR 0.86 [0.46–1.60]; clampless device: 1.8%; OR 0.67 [0.26–1.75]; no aortic manipulation: 2.4%; OR 0.88 [0.37–2.14]). An aggregate analysis including more than 10,000 patients out of the four recent major trials also yielded comparable stroke rates for on- and off-pump CABG (off-pump: 1.4%; on-pump: 1.7%; OR 0.87 [0.64–1.20]). Conclusion Within recent prospective randomized multicenter trials off-pump CABG did not result in lower stroke rates. The possible intrinsic benefit of off-pump CABG may be offset by the complexity of the operative therapy as well as the multiple pathomechanisms involved in perioperative stroke.


Author(s):  
Panagiotis Sarris-Michopoulos ◽  
Evan Markell ◽  
Alejandro Macias ◽  
Michael Magarakis

CABG (Coronary Artery Bypass Grafting) has been the treatment of choice for coronary artery disease for over 50 years and is the most common cardiac surgery procedure performed. Traditionally CABG was performed with the use of cardiopulmonary bypass and the use of cardioplegia to allow the surgeon to operate on a stable field. In the mid-1990s, interest emerged in performing CABG without the use of cardiopulmonary bypass - off pump CABG. This invited commentary focuses on sharing our experience with Low Ejection fraction off-pump CABG and why this approach could be beneficial to this patient population.


Author(s):  
Zachary N. Kon ◽  
Michael H. Kwon ◽  
Michael J. Collins ◽  
Seeta Kallam ◽  
Rupali Sangrampurkar ◽  
...  

Objective It is believed that off-pump coronary artery bypass grafting (OPCAB) leads to hypercoagulability, but efforts to document such a state have been unrevealing. We hypothesized that OPCAB increases the risk of developing a regional hypercoagulable state. Methods Blood was obtained from the aorta and coronary sinus (CS) after CABG performed off- (N = 69) or on-pump (N = 35) to determine the transcardiac gradients of F1.2 (thrombin production), XIIa (coagulation activation), myoglobin (ischemia) and IL-6, IL-8 using ELISA and platelet-derived microparticles using FACS. Platelet function was measured using aggregometry. Regional myocardial pH and SVG flow were recorded intraoperatively. SVG biopsies were analyzed for endothelial integrity (EI) using immunohistochemistry and graft patency was determined by predischarge CT angiography. Results Compared with on-pump, OPCAB provoked significantly higher transcardiac F1.2 (117±200 v. 31±38%), FXII-a (14±29 v. 2±4%), microparticles (14± −9.5% v. 6.4±—4.1%), IL-6 (119±183 v. 28±39%), and a trend toward increased IL-8 (67±94 v. 24±46%, P = 0.077). Myoglobin release after OPCAB, also greater than on-pump CABG (54±89 v. 8±14%, P < 0.01), correlated with regional pH change (R = −0.96, P < 0.0001), and F1.2 release (R = 0.55, P = 0.0002). In contrast, systemic changes in these markers were all less after OPCAB. SVG flow was significantly reduced in OPCAB (39.4 versus 66.5 mL/min, P = 0.0002), but EI and graft patency rates were the same. Conclusions Through the use of transcardiac assays, we illustrated that regional coagulation was enhanced after off- compared with on-pump CABG. If the findings of this pilot study are confirmed, OPCAB may require additional antithrombotic therapies to respond to this local hypercoagulable state.


Author(s):  
Yuki Seto ◽  
Hitoshi Yokoyama ◽  
Shinya Takase ◽  
Masahiro Tanji ◽  
Koki Takahashi ◽  
...  

Objective Enclose II is a new device for proximal coronary artery bypass anastomoses. We evaluated the safety and effectiveness of Enclose II in patients who underwent off-pump coronary artery bypass grafting (CABG). Methods Enclose II was used for isolated off-pump CABG in 178 patients at six heart centers between October 2005 and December 2009. The preoperative characteristics of the patients, complications related to Enclose II, and early graft patency rates were examined. Results A total of 222 proximal anastomoses were performed in 178 patients using Enclose II. Forty-four of these patients had two proximal anastomoses using this device. New cerebral infarction that arose in two patients (1.1%) was not related to Enclose II. No aortic injury occurred. The graft patency rate was 96.4% at 1 year after surgery. Conclusions Enclose II is a safe and useful assist device for proximal anastomoses in patients undergoing off-pump CABG.


2018 ◽  
Vol 10 (2) ◽  
pp. 171-179
Author(s):  
Md Rezaul Karim ◽  
Tawfiq Ahmed ◽  
Shahriar Moinuddin ◽  
Tariq Ahmed Chowdhury ◽  
Moshfequre Rahman Khan

Background:Atrial fibrillation (AF) is the most common postoperative supraventricular arrhythmi. 20% to 40% of patients have AF after coronary artery bypass operation (CABG).Arrhythmia of all grades may occur due to cardiopulmonary bypass (CPB) and injuries inflicted during operativeprocedures. Thus it has been proposed that CABG surgery would be safer if CPB could be avoided.Methods:Total 60 patients who underwentCABG were selected for the study and divided in two groups. Group A: 30 patients with Off-pump CABG (OPCAB) and Group B: 30 patients with On-pump CABG. 12 lead ECG was done at morning on the day of surgery, after surgery & when any arrhythmia are noted for at least 7days. Morbidity of patients like arrhythmia and hospital mortality were recorded and compared during the first week after surgery.Results:Off-pump group (group- A) had less incidence of post-operative AF than on-pump group(group-B) (10% vs 40%). Postoperative blood requirement,total operative time, the period of mechanical ventilation,ICU stay and total postoperative hospital stayis significantly shorter in off-pump than in on-pump group of patients.Conclusion: This study clearly demonstrates that off pump CABG procedure is associated with less incidence of AF. Therefore OPCAB procedure for myocardial revascularization is clearly justified whenever feasible.Cardiovasc. j. 2018; 10(2): 171-179


2007 ◽  
Vol 35 (4) ◽  
pp. 505-509 ◽  
Author(s):  
C. Mitaka ◽  
K. Yokoyama ◽  
T. Imai

The aim of our study was to elucidate the extent to which cardiopulmonary bypass contributes to endogenous nitric oxide (NO) production in patients undergoing coronary artery bypass grafts (CABG). One-hundred-and-sixteen patients undergoing elective CABG with (on-pump, n=66) and without cardiopulmonary bypass (off-pump, n=50) were included. Urinary nitrite/nitrate (NOx) excretion was measured as an index of endogenous NO production during the first two postoperative days. Haemodynamic profiles, serum CK-MB and C-reactive protein (CRP) concentrations were measured after the operation. There was no significant difference in urinary NOx/creatinine (Cr) excretion on day one post CABG. The mean urinary NOx/Cr excretion ratio significantly (P <0.01) decreased from days one to two in the on-pump group, but not in the off-pump group. The mean urinary NOx/Cr excretion ratio was significantly (P<0.01) higher in the off-pump group (0.51± 0.26 μmol/mg) than in the on-pump group (0.38± 0.20 μmol/mg) on day two. The mean serum CRP concentration was also significantly (P <0.01) higher in the off-pump group than in the on-pump group on day two. There was no significant difference in the mean cardiac index or the mean systemic vascular resistance index between the two groups after surgery. The mean serum CK-MB concentration was significantly (P<0.05) lower in the off-pump group than in the on-pump group on days one and two. These findings suggest that endogenous NO production is stimulated by a surgical inflammatory response and that the cardiopulmonary bypass procedure per se is not the inciting stimulus for NO production in patients undergoing CABG.


Perfusion ◽  
2021 ◽  
pp. 026765912199057
Author(s):  
Bo Li ◽  
Haiming Li ◽  
Liangshan Wang ◽  
Changcheng Liu ◽  
Longsheng Dai ◽  
...  

Objective: The purpose of this study was to investigate the effect of different anastomotic positions on the early patency of the distal end-to-side anastomosis of sequential saphenous vein grafts (SVG) in off-pump coronary artery bypass grafting (OPCAB). Methods: A total of 259 patients who underwent OPCAB between August 2014 and August 2019 and presented for coronary computed tomography angiography (CCTA) to evaluate graft patency at 1 year post-OPCAB were analyzed. There are two kinds of distal end-to-side anastomosis of SVG, to posterior descending artery (PDA) and main trunk of right coronary artery (RCA). In all, 1044 distal coronary anastomoses on 518 grafts which included 180 left internal mammary artery (LIMA) grafts, individual 79 SVG and 259 sequential SVG were assessed using CCTA. The blood flow (BF), pulsatility index (PI), and patency of every anastomosis were recorded. Besides, comprehensive data of SV-PDA and SV-RCA patients was also compared. Results: The mean BF of SV-RCA was significantly higher than that of SV-PDA (31.71 ± 18.60 vs 22.62 ± 14.48, p = 0.001), and the PI value of SV-RCA was significantly lower than that of SV-PDA (2.57 ± 1.17 vs 3.50 ± 1.69, p = 0.001). The patency of RCA system was significantly lower than that of the LAD and the left circumflex system (79.25% vs 90.13%, 90.23% respectively, p = 0.001). In sequential SVG, the patency of SV-PDA was significantly lower than that of SV-RCA (74.01% vs 86.59%, p = 0.001). Although, there was no significant difference in left ventricular ejective fraction, the left ventricular end-diastolic diameter (LVDd) in SV-PDA group was significantly larger than that in SV-RCA (52.67 ± 8.72 mm vs 47.34 ± 7.55, p = 0.001). In addition, the target vessel diameter in SV-PDA group was smaller than that in SV-RCA group (1.52 ± 0.41 mm vs 3.17 ± 0.88 mm, p = 0.001). Conclusion: The early patency of sequential SVG end to RCA after OPCAB is generally superior to that of to PDA, especially for patients with large LVDd.


Sign in / Sign up

Export Citation Format

Share Document