Effect of Slip Velocity on Blood Flow Through Composite Stenosed Arteries: A Herschel–Bulkley Fluid Model

2015 ◽  
Vol 38 (3) ◽  
pp. 251-255 ◽  
Author(s):  
Amit Bhatnagar ◽  
R. K. Shrivastav ◽  
A. K. Singh
2021 ◽  
Vol 104 (3) ◽  
pp. 003685042110316
Author(s):  
Salman Akhtar ◽  
Luthais B McCash ◽  
Sohail Nadeem ◽  
Salman Saleem ◽  
Alibek Issakhov

The electro-osmotically modulated hemodynamic across an artery with multiple stenosis is mathematically evaluated. The non-Newtonian behaviour of blood flow is tackled by utilizing Casson fluid model for this flow problem. The blood flow is confined in such arteries due to the presence of stenosis and this theoretical analysis provides the electro-osmotic effects for blood flow through such arteries. The mathematical equations that govern this flow problem are converted into their dimensionless form by using appropriate transformations and then exact mathematical computations are performed by utilizing Mathematica software. The range of the considered parameters is given as [Formula: see text]. The graphical results involve combine study of symmetric and non-symmetric structure for multiple stenosis. Joule heating effects are also incorporated in energy equation together with viscous effects. Streamlines are plotted for electro-kinetic parameter [Formula: see text] and flow rate [Formula: see text]. The trapping declines in size with incrementing [Formula: see text], for symmetric shape of stenosis. But the size of trapping increases for the non-symmetric case.


2015 ◽  
Vol 08 (05) ◽  
pp. 1550064
Author(s):  
Noreen Sher Akbar ◽  
S. Nadeem

In the present paper, we have studied the blood flow through tapered artery with a stenosis. The non-Newtonian nature of blood in small arteries is analyzed mathematically by considering the blood as Phan-Thien–Tanner fluid. The representation for the blood flow is through an axially non-symmetrical but radially symmetric stenosis. Symmetry of the distribution of the wall shearing stress and resistive impedance and their growth with the developing stenosis is another important feature of our analysis. Exact solutions have been evaluated for velocity, resistance impedance, wall shear stress and shearing stress at the stenosis throat. The graphical results of different type of tapered arteries (i.e. converging tapering, diverging tapering, non-tapered artery) have been examined for different parameters of interest.


Sign in / Sign up

Export Citation Format

Share Document