scholarly journals Embedded carbon fiber-reinforced polymer rod in reinforced concrete frame and ultra-high-performance concrete frame joints

2019 ◽  
Vol 11 (S1) ◽  
pp. 35-51
Author(s):  
Shahnaz Basim ◽  
Farzad Hejazi ◽  
Raizal Saifulnaz Bin Muhammad Rashid

AbstractBeam–column joints play an important role in providing lateral stiffness and integrity of frames during dynamic loading such as earthquake. In the high humidity areas, during functioning of the building cracks occur, which leads to the corrosion of the reinforcement due to the environmental exposures. Therefore, one of the main failures mechanism of building during an earthquake is caused by easily yielding of corroded steel reinforcement, which leads to reduce functionality of the frame joints in transferring the loads. This study proposed a new design to reinforce the beam-column joints with embedded carbon fiber-reinforced polymer (CFRP) rods, due to their extremely high strength and stiffness, along with the fact that they will not rust or corrode and very light weight. CFRP rods are used in reinforced concrete (RC) frame and ultra-high-performance concrete (UHPC) frame subjected to dynamic load. The prototype of the proposed design is constructed as frame with conventional concrete and frame with UHPC material to conduct experiments Test as well as numerical analysis to evaluate the performance of the proposed joints under dynamic loads. The results showed improvement in the performance of the frames reinforced with embedded CFRP in joints in terms of lateral load resistance capacity, ductility behaviour, overall stiffness, and failure mechanism.

2020 ◽  
Vol 11 (4) ◽  
pp. 533-553
Author(s):  
Shahnaz Basim ◽  
Farzad Hejazi ◽  
Raizal Saifulnaz Bin Muhammad Rashid ◽  
Milad Hafezolghorani Esfahani

The stiffness and strength of joints are the main factors in providing stability and ductility of a structure during dynamic load such as earthquake. In the high-humidity areas, the reinforcement is exposed to corrosion, which commonly occurs in the joints, due to the presence of micro-cracks in the joints, shrinkage or other concrete casting issues. Therefore, one of the main failure mechanisms of building during an earthquake is caused by damage in the joints in humid areas. This is mainly caused by corroded steel reinforcement, which reduces functionality of the frame joints in transferring the loads. This study proposes a new design for reinforced beam–column joints with embedded carbon fiber–reinforced polymer rods, which possesses extremely high strength and resistance against corrosion and high stiffness. The finite element model for embedded carbon fiber–reinforced polymer in the joints was developed in order to evaluate the performance of the proposed joints during earthquake execution. The developed program was verified through an experimental test on reinforced concrete frame subjected to vibration using dynamic actuator. The finite element program was implemented for one-story reinforced concrete frame and two-story frame building with proposed joints and seismic analysis. The results demonstrated a significant improvement in the performance of the frames reinforced with embedded carbon fiber–reinforced polymer in joints in terms of lateral load resistance capacity and failure mechanism.


Sign in / Sign up

Export Citation Format

Share Document