scholarly journals Relative Body Weight and Standardised Brightness-Mode Ultrasound Measurement of Subcutaneous Fat in Athletes: An International Multicentre Reliability Study, Under the Auspices of the IOC Medical Commission

2019 ◽  
Vol 50 (3) ◽  
pp. 597-614 ◽  
Author(s):  
Wolfram Müller ◽  
Alfred Fürhapter-Rieger ◽  
Helmut Ahammer ◽  
Timothy G. Lohman ◽  
Nanna L. Meyer ◽  
...  

Abstract Introduction Fat is a metabolic fuel, but excess body fat is ballast mass, and therefore, many elite athletes reduce body fat to dangerously low levels. Uncompressed subcutaneous adipose tissue (SAT) thickness measured by brightness-mode ultrasound (US) provides an estimate of body fat content. Methods The accuracy for determining tissue borders is about 0.1–0.2 mm and reliability (experienced measurers) was within ± 1.4 mm (95% limit of agreement, LOA). We present here inter- and intra-measurer scores of three experienced US measurers from each of the centres C1 and C2, and of three novice measurers from each of the centres C3–C5. Each of the five centres measured 16 competitive adult athletes of national or international level, except for one centre where the number was 12. The following sports were included: artistic gymnastics, judo, pentathlon, power lifting, rowing, kayak, soccer, tennis, rugby, basketball, field hockey, water polo, volleyball, American football, triathlon, swimming, cycling, long-distance running, mid-distance running, hurdles, cross-country skiing, snowboarding, and ice hockey. SAT contour was detected semi-automatically: typically, 100 thicknesses of SAT at a given site (i.e., in a given image), with and without fibrous structures, were measured. Results At SAT thickness sums DI (of eight standardised sites) between 6.0 and 70.0 mm, the LOA of experienced measurers was 1.2 mm, and the intra-class correlation coefficient ICC was 0.998; novice measurers: 3.1 mm and 0.988. Intra-measurer differences were similar. The median DI value of all 39 female participants was 51 mm (11% fibrous structures) compared to 17 mm (18%) in the 37 male participants. Discussion DI measurement accuracy and precision enables detection of fat mass changes of approximately 0.2 kg. Such reliability has not been reached with any other method. Although females’ median body mass index and mass index were lower than those of males, females’ median DI was three times higher, and their percentage of fibrous structures was lower. The standardised US method provides a highly accurate and reliable tool for measuring SAT and thus changes in body fat, but training of measurers is important.

Author(s):  
Marietta Sengeis ◽  
Wolfram Müller ◽  
Paul Störchle ◽  
Alfred Fürhapter-Rieger

AbstractBody fat values obtained with various measurement methods deviate substantially in many cases. The standardised brightness-mode ultrasound method was used in 32 Kenyan elite long-distance runners to measure subcutaneous adipose tissue thicknesses at an accuracy and reliability level not reached by any other method. Subcutaneous adipose tissue forms the dominating part of body fat. Additionally, body mass (m), height (h), sitting height (s), leg length, and the mass index MI1 =0.53m/(hs) were determined. MI1 considers leg length, which the body mass index ignores. MI1 values of all participants were higher than their body mass indices. Both indices for relative body weight were within narrow ranges, although thickness sums of subcutaneous adipose tissue deviated strongly (women: 20–82 mm; men: 3–36 mm). Men had 2.1 times more embedded fasciae in the subcutaneous adipose tissue. In the subgroup with personal best times below world record time plus 10%, no correlation between performance and body mass index was found, and there was also no correlation with sums of subcutaneous adipose tissue thicknesses. Within the data ranges found here, extremely low relative body weight or low body fat were no criteria for the level of performance, therefore, pressure towards too low values may be disadvantageous.


Author(s):  
Stein Gerrit Paul Menting ◽  
Brian Hanley ◽  
Marije Titia Elferink-Gemser ◽  
Florentina Johanna Hettinga

1985 ◽  
Vol 53 (4) ◽  
pp. 371-373
Author(s):  
J. Strnad

2016 ◽  
Vol 56 (1) ◽  
pp. 42-52
Author(s):  
Marcel Nemec

Summary The purpose of the study was to identify and analyze the occurrence of cathartic states in a sample of long-distance runners. Data collected via questionnaires were used to evaluate quantitative variables complemented by heuristics while aiming at qualitatively categorize the areas of cathartic states in the context of philosophical and spiritual aspects of long-distance running. The study findings objectify philosophical and spiritual aspects affecting personalities of long-distance runners. The study findings have shown that catharsis represents a relevant philosophical and spiritual aspect affecting long-distance running. We assume that authentic experience of catharsis and its effects motivates runners to perform regular physical activity. The analysis of philosophical and spiritual aspects of long-distance running has revealed a multi-spectral holistic relevance based on the transfer affecting a specific way of life, spectrum of values, ethical personality traits, and also the quality of long-distance runners’ lives.


Sign in / Sign up

Export Citation Format

Share Document