scholarly journals Collapse rates of reinforced concrete structures during large magnitude earthquakes: case study for Romania

2021 ◽  
Vol 3 (5) ◽  
Author(s):  
Florin Pavel

AbstractThis case study focuses on the evaluation of the collapse rates of various types of reinforced concrete structures (residential and industrial) as observed from the data collected in Romania after the Mw 7.4 Vrancea earthquake of March 4, 1977. The results of the analyses show that the largest collapse rates were attributed to elevated reinforced concrete silos and water tanks. Moreover, the majority of the collapsed elevated reinforced concrete water tanks were full at the moment of the seismic event. Very small collapse rates were observed for high-rise residential RC structures and for the multi-storey industrial RC structures.

1977 ◽  
Vol 67 (5) ◽  
pp. 1441-1472
Author(s):  
R. Husid ◽  
A. F. Espinosa ◽  
J. de las Casas

abstract The October 3, 1974, earthquake caused severe damage to buildings of adobe and quincha construction, and also to masonry, reinforced masonry, and reinforced-concrete structures in Lima and vicinity. Most of the damage to well-built structures was due, in part, to the lack of lateral resistance in the original design and to the fact that this earthquake had more energy around 0.4 seconds period than prior destructive earthquakes. Water tanks on the roofs of structures with four or five stories were damaged. Well-engineered single-story buildings were less affected than taller structures. Considerable structural damage to reinforced-concrete structures occurred in the districts of Barranco, La Campiña Molina, and Callao. In La Campiña three-story building partly collapsed and other buildings sustained considerable damage. In La Molina, the buildings of the Agrarian University sustained severe damage, and some collapsed. In Surco, the district adjacent to La Molina, there was no appreciable damage. In Callao, a four-story building collapsed, and the upper half of a concrete silo collapsed. In reinforced-concrete structures, column ties were frequently small in diameter, widely spaced, and not well connected. Usually, the reinforcement of resisting elements had no relation to their stiffnesses. Front columns in school buildings were restrained by high brick walls and had rather short effective lengths to allow building displacement in that direction. The windows in the rear walls gave the rear columns a much greater effective length. Therefore, a longitudinal displacement induces large shear forces in the front columns where most of the severe damage occurred. This problem was not considered in the design of these structures.


2015 ◽  
Vol 1111 ◽  
pp. 187-192
Author(s):  
Corina Sosdean ◽  
Liviu Marsavina ◽  
Geert de Schutter

Reinforced concrete (RC) became one of the most widely used modern building materials. In the last decades a great interest has been shown in studying reinforcement corrosion as it became one of the main factors of degradation and loss of structural integrity of RC structures. The degradation process is accelerated in the case of RC structures situated in aggressive environments like marine environments or subjected to de-icing salts. In this paper it is shown how steel corrosion of the embedded rebars occurs and how this affects the service life of reinforced concrete structures. Also, an experimental study regarding the combined effect of carbonation and chloride ingress was realized. Samples with and without rebars were drilled from a RC slab which was stored in the laboratory for two years. Non-steady state migration tests were realized in order to determine the chloride profile, while the carbonation depth was measured using the colorimetric method based on phenolphthalein spraying. It was concluded that carbonation has a significant effect on chloride ingress, increasing it.


2018 ◽  
Vol 1 (1) ◽  
pp. 702-708
Author(s):  
Onur Onat ◽  
Burak Yön

Failure mode of reinforced concrete (RC) structures are classified according to tension reinforcement ratio of beam elements. To determine effect of tension reinforcement ratio on performance of RC structure, two planar RC structure were selected. One of them is 5 stories other of them is 7 stories. Two different concrete class, C20 and C25, were considered for analysis. Three tension reinforcement combinations were considered, three different tension reinforcement ratios were used. First case is the ratio of the tension reinforcement is lower than that of the compression reinforcement, second case is the ratio of the tension reinforcement is equal to the ratio of the compression reinforcement and third case is the ratio of the tensile reinforcement is higher than the compression reinforcement.


Sign in / Sign up

Export Citation Format

Share Document