Ceiling temperature assessment of a reduced scale tunnel in the event of two hydrogen jet fires

Author(s):  
Shibani ◽  
Fatemeh Salehi ◽  
N. Suresh Kumar Reddy ◽  
Salman Jalalifar ◽  
Rouzbeh Abbassi
Author(s):  
Felipe Santos de Castro ◽  
Eduardo Tadashi Katsuno ◽  
Andre Mitsuo Kogishi ◽  
José Marcos Paz de Souza ◽  
Joao Lucas Dozzi Dantas Dantas

Author(s):  
Giuseppe Starace ◽  
Lorenzo Falcicchia ◽  
Pierpaolo Panico ◽  
Maria Fiorentino ◽  
Gianpiero Colangelo

AbstractIn refrigeration systems, evaporative condensers have two main advantages compared to other condensation heat exchangers: They operate at lower condensation temperature than traditional air-cooled condensers and require a lower quantity of water and pumping power compared to evaporative towers. The heat and mass transfer that occur on tube batteries are difficult to study. The aim of this work is to apply an experimental approach to investigate the performance of an evaporative condenser on a reduced scale by means of a test bench, consisting of a transparent duct with a rectangular test section in which electric heaters, inside elliptical pipes (major axis 32 mm, minor axis 23 mm), simulate the presence of the refrigerant during condensation. By keeping the water conditions fixed and constant, the operating conditions of the air and the inclination of the heat transfer geometry were varied, and this allowed to carry out a sensitivity analysis, depending on some of the main parameters that influence the thermo-fluid dynamic phenomena, as well as a performance comparison. The results showed that the heat transfer increases with the tube surface exposed directly to the air as a result of the increase in their inclination, that has been varied in the range 0–20°. For the investigated conditions, the average increase, resulting by the inclination, is 28%.


Structures ◽  
2021 ◽  
Vol 32 ◽  
pp. 2020-2031
Author(s):  
Guolong Zhang ◽  
Qingwen Zhang ◽  
Feng Fan ◽  
Shizhao Shen

Author(s):  
Marcio Yamamoto ◽  
Sotaro Masanobu ◽  
Satoru Takano ◽  
Shigeo Kanada ◽  
Tomo Fujiwara ◽  
...  

In this article, we present the numerical analysis of a Free Standing Riser. The numerical simulation was carried out using a commercial riser analysis software suit. The numerical model’s dimensions were the same of a 1/70 reduced scale model deployed in a previous experiment. The numerical results were compared with experimental results presented in a previous article [1]. Discussion about the model and limitations of the numerical analysis is included.


Author(s):  
Ayoub Gounni ◽  
Mustapha El Alami

In order to really assess the thermal performance of a wall incorporating phase change material (PCM), a reduced scale cavity has been monitored during two heating cycles. For each cycle, the heat source inside the test cell is switched “on” for 5 h and its setpoint is 38 °C and then switched off for 4 h. The outdoor air temperature is kept constant at a low temperature of 20 °C. Two walls are equipped with a PCM layer at different depths in order to study the optimal PCM location. The two other walls are wooden and glass to model a real building. The comparison between the four walls is made based on the absorbed heat fluxes and outside surface temperatures. The results show that the location of the PCM close to the heat source reaches its melting temperature and then reduces the surface temperature. At this location, the PCM layer stores the major part of the inlet heat flux. It takes 10 h to release the absorbed heat flux. However, the PCM layer, practically, does not have an effect on the surface temperatures and absorbed heat fluxes, when it is placed far from the heat source.


Sign in / Sign up

Export Citation Format

Share Document