Field tests of geophysical techniques for predicting and monitoring leach solution flow during in situ mining

1991 ◽  
Vol 28 (3-4) ◽  
pp. 251-268 ◽  
Author(s):  
Daryl R. Tweeton ◽  
Calvin L. Cumerlato ◽  
Jay C. Hanson ◽  
Harland L. Kuhlman
Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4863
Author(s):  
Victor Dyomin ◽  
Alexandra Davydova ◽  
Igor Polovtsev ◽  
Alexey Olshukov ◽  
Nikolay Kirillov ◽  
...  

The paper presents an underwater holographic sensor to study marine particles—a miniDHC digital holographic camera, which may be used as part of a hydrobiological probe for accompanying (background) measurements. The results of field measurements of plankton are given and interpreted, their verification is performed. Errors of measurements and classification of plankton particles are estimated. MiniDHC allows measurement of the following set of background data, which is confirmed by field tests: plankton concentration, average size and size dispersion of individuals, particle size distribution, including on major taxa, as well as water turbidity and suspension statistics. Version of constructing measuring systems based on modern carriers of operational oceanography for the purpose of ecological diagnostics of the world ocean using autochthonous plankton are discussed. The results of field measurements of plankton using miniDHC as part of a hydrobiological probe are presented and interpreted, and their verification is carried out. The results of comparing the data on the concentration of individual taxa obtained using miniDHC with the data obtained by the traditional method using plankton catching with a net showed a difference of no more than 23%. The article also contains recommendations for expanding the potential of miniDHC, its purpose indicators, and improving metrological characteristics.


2017 ◽  
Vol 10 (6) ◽  
pp. 2077-2091 ◽  
Author(s):  
Sabina Assan ◽  
Alexia Baudic ◽  
Ali Guemri ◽  
Philippe Ciais ◽  
Valerie Gros ◽  
...  

Abstract. Due to increased demand for an understanding of CH4 emissions from industrial sites, the subject of cross sensitivities caused by absorption from multiple gases on δ13CH4 and C2H6 measured in the near-infrared spectral domain using CRDS has become increasingly important. Extensive laboratory tests are presented here, which characterize these cross sensitivities and propose corrections for the biases they induce. We found methane isotopic measurements to be subject to interference from elevated C2H6 concentrations resulting in heavier δ13CH4 by +23.5 ‰ per ppm C2H6 ∕ ppm CH4. Measured C2H6 is subject to absorption interference from a number of other trace gases, predominantly H2O (with an average linear sensitivity of 0.9 ppm C2H6 per  % H2O in ambient conditions). Yet, this sensitivity was found to be discontinuous with a strong hysteresis effect and we suggest removing H2O from gas samples prior to analysis. The C2H6 calibration factor was calculated using a GC and measured as 0.5 (confirmed up to 5 ppm C2H6). Field tests at a natural gas compressor station demonstrated that the presence of C2H6 in gas emissions at an average level of 0.3 ppm shifted the isotopic signature by 2.5 ‰, whilst after calibration we find that the average C2H6 : CH4 ratio shifts by +0.06. These results indicate that, when using such a CRDS instrument in conditions of elevated C2H6 for CH4 source determination, it is imperative to account for the biases discussed within this study.


Sensors ◽  
2018 ◽  
Vol 18 (12) ◽  
pp. 4406 ◽  
Author(s):  
Rafael Sola-Guirado ◽  
Sergio Bayano-Tejero ◽  
Antonio Rodríguez-Lizana ◽  
Jesús Gil-Ribes ◽  
Antonio Miranda-Fuentes

Canopy characterization has become important when trying to optimize any kind of agricultural operation in high-growing crops, such as olive. Many sensors and techniques have reported satisfactory results in these approaches and in this work a 2D laser scanner was explored for measuring canopy trees in real-time conditions. The sensor was tested in both laboratory and field conditions to check its accuracy, its cone width, and its ability to characterize olive canopies in situ. The sensor was mounted on a mast and tested in laboratory conditions to check: (i) its accuracy at different measurement distances; (ii) its measurement cone width with different reflectivity targets; and (iii) the influence of the target’s density on its accuracy. The field tests involved both isolated and hedgerow orchards, in which the measurements were taken manually and with the sensor. The canopy volume was estimated with a methodology consisting of revolving or extruding the canopy contour. The sensor showed high accuracy in the laboratory test, except for the measurements performed at 1.0 m distance, with 60 mm error (6%). Otherwise, error remained below 20 mm (1% relative error). The cone width depended on the target reflectivity. The accuracy decreased with the target density.


1995 ◽  
Author(s):  
Shrini Upadhyaya ◽  
Dan Wolf ◽  
William J. Chancellor ◽  
Itzhak Shmulevich ◽  
Amos Hadas

The objectives of this study were to investigate soil-pneumatic tire interaction and develop traction-soil compaction prediction model. We have developed an inverse solution technique that employs a response surface methodology to determine engineering properties of soil in-situ. This technique is useful in obtaining actual properties of soil in-situ for use in traction and soil compaction studies rather than using the values obtained in the laboratory by employing remolded and/or disturbed soil samples. We have conducted extensive field tests i the U.S. to develop semi-empirical traction prediction equation for radial ply tires. A user friendly traction-soil compaction program was developed to predict tractive ability of radial ply tires using several different techniques and to estimate soil compaction induced by these tires. A traction prediction model that incorporates strain rate effects on the tractive ability of tires was developed in Israel. A mobile single wheel tester and an in-situ soil test device were developed i Israel to significantly enhance the ability of Israeli investigators to conduct traction-soil compaction research. This project has resulted in close cooperation between UCD, Technion, and ARO, which will be instrumental in future collaboration.


A good knowledge about a site including its subsurface conditions is very important in its safe and economical development. It is therefore an essential preliminary to the construction of any civil engineering work. This chapter outlines the objectives of site characterization and the general objectives of geotechnical investigation. It discusses the phases of field investigation and the stages of a full exploratory program including methods of sample recovery and field tests and sampling methods. Geophysical techniques can contribute very greatly to the process of ground investigation by allowing an assessment, in qualitative terms, of the lateral variability and vertical profiling of the near-surface materials beneath a site. Some of these geophysical techniques are discussed in the chapter. Laboratory examination/verification and testing should be made of representative portions of the samples to establish appropriate soil parameters. Some soil parameters may be estimated by correlations. The results of the subsurface investigation and related testing, together with interpretations, discussions, and foundation recommendations, are usually presented in the form of a detailed soil report.


Sensors ◽  
2020 ◽  
Vol 20 (9) ◽  
pp. 2662
Author(s):  
Shifan Qiao ◽  
Chaobo Feng ◽  
Pengkun Yu ◽  
Junkun Tan ◽  
Taro Uchimura ◽  
...  

In recent decades, early warning systems to predict the occurrence of landslides using tilt sensors have been developed and employed in slope monitoring due to their low cost and simple installation. Although many studies have been carried out to validate the efficiency of these early warning systems, few studies have been carried out to investigate the tilting direction of tilt sensors at the slope surface, which have revealed controversial results in field monitoring. In this paper, the tilting direction and the pre-failure tilting behavior of slopes were studied by performing a series of model tests as well as two field tests. These tests were conducted under various testing conditions. Tilt sensors with different rod lengths were employed to investigate the mechanism of surface tilting. The test results show that the surface tilting measured by the tilt sensors with no rods and those with short rods located above the slip surface are consistent, while the tilting monitored by the tilt sensors with long rods implies an opposite rotational direction. These results are important references to understand the controversial surface tilting behavior in in situ landslide monitoring cases and imply the correlation between the depth of the slip surface of the slope and the surface tilting in in situ landslide monitoring cases, which can be used as the standard for tilt sensor installation in field monitoring.


1982 ◽  
Vol 22 (01) ◽  
pp. 141-150 ◽  
Author(s):  
Muhammad I. Kabir ◽  
Larry W. Lake ◽  
Robert S. Schechter

Abstract In-situ leach mining for uranium is an emerging technology. Currently, the selection of a well pattern designed to recover mineral values is governed primarily by arguments based on hydrological considerations. The effects of well pattern and well spacing on uranium recovery and oxidant utilization are considered in this paper. As expected, formation permeability heterogeneities and anisotropies are found to be important issues requiring careful consideration, however, it also is shown that chemical factors cannot be ignored. In particular, it is shown that the oxidant efficiency and the produced uranium solution concentrations are sensitive to the presence of other minerals competing with uranium for oxidant. If the Damkohler number for competing minerals, which measures the speed of the reaction, exceeds that for uranium, the competing mineral will have to be oxidized completely to recover a large proportion of the uranium. If the Damkohler number is smaller, it may be possible to achieve considerable selectivity for uranium by adjusting the well spacing. It also is shown that the oxidant efficiency is generally highest for well patterns that give streamlines of roughly equal length and that there is a minimum distance between injection and production wells to utilize oxidant most advantageously. Introduction In-situ solution mining is a process whereby uranium is recovered from permeable sandstone bodies by injecting and producing a leach solution through an array of wells penetrating the mineralized zone. It appears to have broad application and in many situations offers both economic and environmental advantages. The processes may be classified generally as acid or alkaline, but the general features of both are the same. The insoluble uranium in the mineralized zone is in the +4 state of oxidation. To be mobilized, the uranium must be oxidized to the +6 state and complexed either with sulfate in the case of acid leaching or carbonate in the case of alkaline leaching to form highly soluble uranyl sulfates or carbonates. The leach solutions, therefore, contain an oxidant (oxygen, hydrogen peroxide, ferric cations, sodium hyperchlorite, etc.) together with a complexing agent (anion). The choice of leach solution depends on a number of factors including selectivity and injectivity. For example, formations containing more than 1 wt% carbonates are not likely to be candidates for acid leaching because of the large acid requirement and because of permeability loss due to precipitation of calcium sulfate. It is the purpose of this paper to consider the technical factors (as opposed to economic) that govern the choice of well pattern to be used for leaching. The discussion is structured so that the conclusions apply to both alkaline and acid lixiviants and to any oxidant, although an occasional reference to a particular oxidant may appear. Considerable use is made of the computer simulator previously reported. The computational details are available in that paper. A number of factors that pertain to the selection of a well pattern are considered. It is shown that the effectiveness of the oxidant - i.e., the uranium recovered per unit of oxidant injected - is related to the well pattern, to the reaction rates, and to the permeability variations, especially if the formation is anisotropic. Furthermore, the spacing between wells is related to reactions with oxidizable minerals that compete for oxidant. These considerations can be quantified to some extent by studying linear systems. Linear Flow Systems SPEJ P. 132^


2003 ◽  
Vol 57 (6) ◽  
pp. 607-613 ◽  
Author(s):  
H. Steiner ◽  
M. Jakusch ◽  
M. Kraft ◽  
M. Karlowatz ◽  
T. Baumann ◽  
...  

A prototype mid-infrared sensor system for the determination of volatile organic pollutants in groundwater was developed and tested under real-world conditions. The sensor comprises a portable Fourier transform infrared spectrometer, coupled to the sensor head via mid-infrared transparent silver halide fiber-optic cables. A 10 cm unclad middle section of the 6-m-long fiber is coated with ethylene propylene copolymer in order to enrich the analytes within the penetration depth of the evanescent field protruding from the fiber sensor head. A mixture of tetrachloroethylene, dichlorobenzene, diethyl phthalate, and xylene isomers at concentrations in the low ppm region was investigated qualitatively and quantitatively in an artificial aquifer system filled with Munich gravel. This simulated real-world site at a pilot scale enables in situ studies of the sensor response and spreading of the pollutants injected into the system with controlled groundwater flow. The sensor head was immersed into a monitoring well of the aquifer system at a distance of 1 m downstream of the sample inlet and at a depth of 30 cm. Within one hour, the analytes were clearly identified in the fingerprint region of the IR spectrum (1300 to 700 cm−1). The results have been validated by head-space gas chromatography, using samples collected during the field measurement. Five out of six analytes could be discriminated simultaneously; for two of the analytes the quantitative results are in agreement with the reference analysis.


2019 ◽  
Vol 27 (5) ◽  
pp. 5559-5571 ◽  
Author(s):  
Therese M. Karlsson ◽  
Anna Kärrman ◽  
Anna Rotander ◽  
Martin Hassellöv

AbstractOwing to the development and adoption of a variety of methods for sampling and identifying microplastics, there is now data showing the presence of microplastics in surface waters from all over the world. The difference between the methods, however, hampers comparisons, and to date, most studies are qualitative rather than quantitative. In order to allow for a quantitative comparison of microplastics abundance, it is crucial to understand the differences between sampling methods. Therefore, a manta trawl and an in situ filtering pump were compared during realistic, but controlled, field tests. Identical microplastic analyses of all replicates allowed the differences between the methods with respect to (1) precision, (2) concentrations, and (3) composition to be assessed. The results show that the pump gave higher accuracy with respect to volume than the trawl. The trawl, however, sampled higher concentrations, which appeared to be due to a more efficient sampling of particles on the sea surface microlayer, such as expanded polystyrene and air-filled microspheres. The trawl also sampled a higher volume, which decreased statistical counting uncertainties. A key finding in this study was that, regardless of sampling method, it is critical that a sufficiently high volume is sampled to provide enough particles for statistical evaluation. Due to the patchiness of this type of contaminant, our data indicate that a minimum of 26 particles per sample should be recorded to allow for concentration comparisons and to avoid false null values. The necessary amount of replicates to detect temporal or spatial differences is also discussed. For compositional differences and size distributions, even higher particle counts would be necessary. Quantitative measurements and comparisons would also require an unbiased approach towards both visual and spectroscopic identification. To facilitate the development of such methods, a visual protocol that can be further developed to fit different needs is introduced and discussed. Some of the challenges encountered while using FTIR microspectroscopic particle identification are also critically discussed in relation to specific compositions found.


Sign in / Sign up

Export Citation Format

Share Document