On the reliability of mass-size distributions measured by cascade impactors

1979 ◽  
Vol 10 (2) ◽  
pp. 225 ◽  
Author(s):  
Axel Berner ◽  
Christian Lürzer
2016 ◽  
Author(s):  
A. S. Fonseca ◽  
N. Talbot ◽  
J. Schwarz ◽  
J. Ondráček ◽  
V. Ždímal ◽  
...  

Abstract. Due to the need to better characterise the ultrafine particles fraction and related personal exposure, several impactors have been developed to enable the collection of ultrafine particles (<100 nm). However, to the authors’ kno wledge there have been no field campaigns to-date intercomparing impactor collection of ultrafine particles. The purpose of this study was two-fold: 1) to assess the performance of a number of conventional and nano-range cascade impactors with regard to the particle mass size distribution under different environmental conditions and aerosol loads and types, and 2) to characterise aerosol size distributions including ultrafine particles using impactors in 2 European locations. The impactors used were: (i) Berner low-pressure impactor (BLPI; 26 nm - 13.5 μm), (ii) nano-Berner low-pressure impactor (nano-BLPI; 11 nm - 1.95 μm) and (iii) Nano-microorifice uniform deposit impactor (nano-Moudi; 10 nm-18 μm), and (iv) Personal cascade impactor Sioutas (PCIS; <250 nm - 10 μm). Taking the BLPI as an internal reference, the best agreement regarding mass size distributions was obtained with the nano-BLPI, independently of the aerosol load and aerosol chemical composition. The nano-Moudi showed a good agreement for part icle sizes >320 nm, whereas for particle diameters <320 nm this instrument recorded larger mass concentrations in outdoor air than the internal reference. This difference could be due to particle bounce, to the dissociation of semi volatiles in the coarser stages and/or to particle shrinkage during transport through the impactor due to higher temperature inside this impactor. Further research is needed to understand this behaviour. With regard to the PCIS, their size-resolved mass concentrations were compar able with other impactors for PM1, PM2 and PM10, but the cut-off at 250 nm did not seem to be consistent with that of the internal reference.


2004 ◽  
Vol 38 (20) ◽  
pp. 3127-3141 ◽  
Author(s):  
Juan C. Cabada ◽  
Sarah Rees ◽  
Satoshi Takahama ◽  
Andrey Khlystov ◽  
Spyros N. Pandis ◽  
...  

2012 ◽  
Vol 5 (12) ◽  
pp. 3077-3097 ◽  
Author(s):  
M. Laborde ◽  
M. Schnaiter ◽  
C. Linke ◽  
H. Saathoff ◽  
K.-H. Naumann ◽  
...  

Abstract. Soot particles, consisting of black carbon (BC), organic carbon (OC), inorganic salts, and trace elements, are emitted into the atmosphere during incomplete combustion. Accurate measurements of atmospheric BC are important as BC particles cause adverse health effects and impact the climate. Unfortunately, the accurate measurement of the properties and mass concentrations of BC particles remains difficult. The Single Particle Soot Photometer (SP2) can contribute to improving this situation by measuring the mass of refractory BC in individual particles as well as its mixing state. Here, the results of the first detailed SP2 intercomparison, involving 6 SP2s from 6 different research groups, are presented, including the most evolved data products that can presently be calculated from SP2 measurements. It was shown that a detection efficiency of almost 100% down to 1 fg BC per particle can readily be achieved, and that this limit can be pushed down to ∼0.2 fg BC with optimal SP2 setup. Number and mass size distributions of BC cores agreed within ±5% and ±10%, respectively, in between the SP2s, with larger deviations in the range below 1 fg BC. The accuracy of the SP2's mass concentration measurement depends on the calibration material chosen. The SP2 has previously been shown to be equally sensitive to fullerene soot and ambient BC from sources where fossil fuel was dominant and less sensitive to fullerene soot than to Aquadag. Fullerene soot was therefore chosen as the standard calibration material by the SP2 user community; however, many data sets rely solely on Aquadag calibration measurements. The difference in SP2 sensitivity was found to be almost equal (fullerene soot to Aquadag response ratio of ∼0.75 at 8.9 fg BC) for all SP2s. This allows the calculation of a fullerene soot equivalent calibration curve from a measured Aquadag calibration, when no fullerene soot calibration is available. It could be shown that this approach works well for all SP2s over the mass range of 1–10 fg. This range is suitable for typical BC mass size distributions in the ambient air far from sources. The number size distribution of purely scattering particles optically measured by the 6 SP2s also agreed within 15%. Measurements of the thickness of non-refractory coatings (i.e. product from α-pinene ozonolysis) on the BC particles, relying on BC mass optical size and on an additional particle position measurement, also compared well (within ±17%). The estimated coating thickness values were consistent with thermo-optical analysis of OC and elemental carbon (EC) content, though absolutely accurate values cannot be expected given all the assumptions that have to be made regarding refractive index, particle morphology, etc. This study showed that the SP2 provides accurate and reproducible data, but also that high data quality is only achieved if the SP2 is carefully tuned and calibrated. It has to be noted that the agreement observed here does not account for additional variability in output data that could result from the differences in the potentially subjective assumptions made by different SP2 users in the data processing.


1996 ◽  
Vol 101 (D14) ◽  
pp. 19483-19493 ◽  
Author(s):  
C. A. Rivera-Carpio ◽  
C. E. Corrigan ◽  
T. Novakov ◽  
J. E. Penner ◽  
C. F. Rogers ◽  
...  

2016 ◽  
Vol 2016 ◽  
pp. 1-8 ◽  
Author(s):  
Jiangfeng Shao ◽  
Jiandong Mao

Dust particle size distributions in Yinchuan, China, were measured during March and April 2014, using APS-3321 sampler. The distributions were measured under different dust conditions (background, floating dust, blowing dust, and dust storm) and statistical analyses were performed. The results showed that, under different dust conditions, the instantaneous number concentrations of dust particles differed widely. For example, during blowing sand and dust storm conditions, instantaneous dust particles concentrations varied substantially, while, under floating dust conditions, concentration differences were relatively small. The average dust particles size distributions were unimodal under all dust conditions, but the average surface area and mass size distributions were all bimodal. These distributions had peaks in different locations under different dust conditions. Under different dust conditions, wind speed and humidity were very important factors for particles size distributions. With increasing wind speed and decreasing humidity, fine particles were dominant in the atmosphere and the number and mass distributions of the coarse particles were indicative of long-range transport from surrounding deserts. Different dust conditions had different influences on PM1, PM2.5, and PM10concentrations.