Order parameters for a spherical model of a ferromagnetic; connections to alloy theory

1966 ◽  
Vol 23 (11) ◽  
pp. 653-654
Author(s):  
J. Philhours ◽  
G.L. Hall
1976 ◽  
Vol 37 (C4) ◽  
pp. C4-289-C4-292
Author(s):  
S. K. GHATAK ◽  
M. AVIGNON ◽  
K. H. BENNEMANN

1981 ◽  
Vol 133 (1) ◽  
pp. 103 ◽  
Author(s):  
M.A. Anisimov ◽  
E.E. Gorodetskii ◽  
V.M. Zaprudskii

Author(s):  
F. Riva ◽  
T. Fracasso ◽  
A. Guerra ◽  
P. Genet

AbstractIn shooting crimes, ballistics tests are often recommended in order to reproduce the wound characteristics of the involved persons. For this purpose, several “simulants” can be used. However, despite the efforts in the research of “surrogates” in the field of forensic ballistic, the development of synthetic models needs still to be improved through a validation process based on specific real caseworks. This study has been triggered by the findings observed during the autopsy performed on two victims killed in the same shooting incident, with similar wounding characteristics; namely two retained head shots with ricochet against the interior wall of the skull; both projectiles have been recovered during the autopsies after migration in the brain parenchyma. The thickness of the different tissues and structures along the bullets trajectories as well as the incident angles between the bullets paths and the skull walls have been measured and reproduced during the assemblage of the synthetic head models. Two different types of models (“open shape” and “spherical”) have been assembled using leather, polyurethane and gelatine to simulate respectively skin, bone and soft tissues. Six shots have been performed in total. The results of the models have been compared to the findings of post-mortem computed tomography (PMCT) and the autopsy findings.Out of the six shots, two perforated the models and four were retained. When the projectile was retained, the use of both models allowed reproducing the wounds characteristics observed on both victims in terms of penetration and ricochet behaviour. However, the projectiles recovered from the models showed less deformation than the bullets collected during the autopsies. The “open shape” model allowed a better controlling on the shooting parameters than the “spherical” model. Finally, the difference in bullet deformation could be caused by the choice of the bone simulant, which might under-represent either the strength or the density of the human bone. In our opinion, it would be worth to develop a new, more representative material for ballistic which simulates the human bone.


Polymers ◽  
2020 ◽  
Vol 12 (6) ◽  
pp. 1262
Author(s):  
Mikhail A. Osipov ◽  
Maxim V. Gorkunov ◽  
Alexander A. Antonov

Density functional theory of rod-coil diblock copolymers, developed recently by the authors, has been generalised and used to study the liquid crystal ordering and microphase separation effects in the hexagonal, lamellar and nematic phases. The translational order parameters of rod and coil monomers and the orientational order parameters of rod-like fragments of the copolymer chains have been determined numerically by direct minimization of the free energy. The phase diagram has been derived containing the isotropic, the lamellar and the hexagonal phases which is consistent with typical experimental data. The order parameter profiles as functions of temperature and the copolymer composition have also been determined in different anisotropic phases. Finally, the spatial distributions of the density of rigid rod fragments and of the corresponding orientational order parameter in the hexagonal phase have been calculated.


Sign in / Sign up

Export Citation Format

Share Document