A novel analysis method for plasma light and soft X-ray tomography data including the three-dimensional diffusion in a semiconductor detector array

1996 ◽  
Vol 80 ◽  
pp. 279-282
Author(s):  
J. Kohagura ◽  
T. Cho ◽  
M. Hirata ◽  
K. Yatsu ◽  
T. Tamano ◽  
...  
2018 ◽  
Vol 25 (5) ◽  
pp. 1478-1489 ◽  
Author(s):  
Rafael Vescovi ◽  
Ming Du ◽  
Vincent de Andrade ◽  
William Scullin ◽  
Dogˇa Gürsoy ◽  
...  

X-rays offer high penetration with the potential for tomography of centimetre-sized specimens, but synchrotron beamlines often provide illumination that is only millimetres wide. Here an approach is demonstrated termed Tomosaic for tomographic imaging of large samples that extend beyond the illumination field of view of an X-ray imaging system. This includes software modules for image stitching and calibration, while making use of existing modules available in other packages for alignment and reconstruction. The approach is compatible with conventional beamline hardware, while providing a dose-efficient method of data acquisition. By using parallelization on a distributed computing system, it provides a solution for handling teravoxel-sized or larger datasets that cannot be processed on a single workstation in a reasonable time. Using experimental data, the package is shown to provide good quality three-dimensional reconstruction for centimetre-sized samples with sub-micrometre pixel size.


2004 ◽  
Vol 74 (1-4) ◽  
pp. 253-264 ◽  
Author(s):  
Yoshito Nakashima ◽  
Tsukasa Nakano ◽  
Koichi Nakamura ◽  
Kentaro Uesugi ◽  
Akira Tsuchiyama ◽  
...  

2011 ◽  
Vol 19 (1) ◽  
pp. 114-125 ◽  
Author(s):  
Sabrina Lang ◽  
Marco Dominietto ◽  
Philippe Cattin ◽  
Alexandra Ulmann-Schuler ◽  
Timm Weitkamp ◽  
...  

The visualization of the vascular network in tumors down to the smallest vessels requires high spatial resolution and reasonable contrast. Stained corrosion casts of the microvasculature network guarantee superior X-ray absorption contrast and highest reproduction fidelity. Tomography of a centimeter-size tumor, however, is unfeasible at the spatial resolution needed to reveal the smallest vessels. Therefore, local tomography has been performed to visualize the smallest capillaries within the region of interest. These three-dimensional data show the detailed morphology, but the reconstructed absorption coefficients obtained in local tomography differ substantially from the absorption coefficients retrieved from the less detailed global tomography data. This paper deals with the adaptation of local tomography data using the global data and considers two-parameter histogram matching of the radiographs, sinogram extension, and multi-parameter cupping correction. It is demonstrated that two-parameter histogram matching of the radiographs already provides reasonable agreement. The change of the lens in front of the detector's camera, however, significantly affects the obtained local X-ray absorption coefficients in the tomograms predominantly owing to the dissimilar point-spread functions of the two configurations used, and much less to the fact that one of the data sets was acquired in a local geometry.


2020 ◽  
Vol 1004 ◽  
pp. 519-524 ◽  
Author(s):  
Shinichi Shikata ◽  
Naoya Akashi

X-ray topography is an effective tool to investigate dislocations in semiconductor crystals. Due to low X-ray absorption coefficients of diamond, X-rays can penetrate deep into the crystal. Thus, deep three-dimensional (3D) dislocations are projected on two-dimension (2D) film, which makes dislocation analysis particularly challenging. Dislocation vectors from the films obtained using a set of the same diffraction vectors were identified using topographical and geometrical analyses. The depth and position of the dislocations in a crystal that was projected on a film were determined using geometrical relationship. The proposed analysis method was verified by analyzing several dislocations using four <404> diffraction films. The types of dislocation were identified through Burgers vector analysis.


Sign in / Sign up

Export Citation Format

Share Document