An analysis of electrodisintegration of nuclei using E1 virtual radiation spectra evaluated with coulomb distorted waves

1975 ◽  
Vol 244 (2) ◽  
pp. 205-212 ◽  
Author(s):  
E. Wolynec ◽  
G. Moscati ◽  
O.D. Gonçalves ◽  
M.N. Martins
2020 ◽  
pp. 89-96
Author(s):  
Sergei S. Kapitonov ◽  
Alexei S. Vinokurov ◽  
Sergei V. Prytkov ◽  
Sergei Yu. Grigorovich ◽  
Anastasia V. Kapitonova ◽  
...  

The article describes the results of comprehensive study aiming at increase of quality of LED luminaires and definition of the nature of changes in their correlated colour temperature (CCT) in the course of operation. Dependences of CCT of LED luminaires with remote and close location of phosphor for 10 thousand hours of operation in different electric modes were obtained; the results of comparison between the initial and final radiation spectra of the luminaires are presented; using mathematical statistics methods, variation of luminaire CCT over the service period claimed by the manufacturer is forecast; the least favourable electric operation modes with the highest CCT variation observed are defined. The obtained results have confirmed availability of the problem of variation of CCT of LED luminaires during their operation. Possible way of its resolution is application of more qualitative and therefore expensive LEDs with close proximity of phosphor or LEDs with remote phosphor. The article may be interesting both for manufacturers and consumers of LED light sources and lighting devices using them.


Author(s):  
Юрій Юрійович Свида ◽  
Марія Іллівна Суховія ◽  
Микола Олексійович Маргітич ◽  
Мирослав Іванович Шафраньош ◽  
Іван Іванович Шафраньош

2019 ◽  
Vol 46 (No. 2) ◽  
pp. 98-106 ◽  
Author(s):  
Filippos Bantis ◽  
Kalliopi Radoglou

The effect of light-emitting diodes (LED) with broad radiation spectra on developmental, physiological, and phytochemical characteristics of Greek sage (Salvia fruticosa L.) seedlings was assessed. Fluorescent (FL – control) tubes and four LED lights [AP67 (moderate blue, red and far-red), L20AP67 (moderate blue, red and far-red, high green), AP673L (moderate blue, high red) and NS1 (high blue and green, low red, high red : far-red, 1% ultraviolet)] were used in a growth chamber. Seedlings grown under FL, L20AP67 and AP673L exhibited the best morphological and developmental characteristics. FL led to inferior root biomass formation compared to all LEDs. AP67 promoted greater root-to-shoot dry weight ratio and dry-to-fresh overground and root weight ratios, but induced the least morphological and developmental characteristics. NS1 performed well regarding the root biomass production. Total phenolic content and the root growth capacity were not significantly affected. The present study demonstrates that L20AP67 and AP673L LEDs performed equally to FL light regarding the developmental characteristics. AP67 and NS1 may have the potential to be used for compact seedling production.


1962 ◽  
Vol 1 (7) ◽  
pp. 295-297 ◽  
Author(s):  
D.K. McDaniels ◽  
D.L. Hendrie ◽  
R.H. Bassel ◽  
G.R. Satchler

1986 ◽  
Vol 45 (3) ◽  
pp. 953-957
Author(s):  
A. I. Proskura ◽  
I. V. Zakharchenko

Sign in / Sign up

Export Citation Format

Share Document