Acoustic, Electromagnetic and Optical Sensing and Monitoring Methods

2018 ◽  
pp. 43-139 ◽  
Author(s):  
Wen Xiao ◽  
Xiaosu Yi ◽  
Feng Pan ◽  
Rui Li ◽  
Tian Xia
2021 ◽  
Vol 11 (8) ◽  
pp. 3642
Author(s):  
Oleg Bukin ◽  
Dmitry Proschenko ◽  
Denis Korovetskiy ◽  
Alexey Chekhlenok ◽  
Viktoria Yurchik ◽  
...  

The oil pollution of seas is increasing, especially in local areas, such as ports, roadsteads of the vessels, and bunkering zones. Today, methods of monitoring seawater are costly and applicable only in the case of big ecology disasters. The development of an operative and reasonable project for monitoring the sea surface for oil slick detection is described in this article using drones equipped with optical sensing and artificial intelligence. The monitoring system is implemented in the form of separate hard and soft frameworks (HSFWs) that combine monitoring methods, hardware, and software. Three frameworks are combined to fulfill the entire monitoring mission. HSFW1 performs the function of autonomous monitoring of thin oil slicks on the sea surface, using computer vision with AI elements for detection, segmentation, and classification of thin slicks. HSFW2 is based on the use of laser-induced fluorescence (LIF) to identify types of oil products that form a slick or that are in a dissolved state, as well as measure their concentration in solution. HSFW3 is designed for autonomous navigation and drone movement control. This article describes AI elements and hardware complexes of the three separate frameworks designed to solve the problems with monitoring slicks of oil products on the sea surface and oil products dissolved in seawater. The results of testing the HSFWs for the detection of pollution caused by marine fuel slicks are described.


Diabetology ◽  
2022 ◽  
Vol 3 (1) ◽  
pp. 56-71
Author(s):  
Nicholas B. Davison ◽  
Christopher J. Gaffney ◽  
Jemma G. Kerns ◽  
Qiandong D. Zhuang

Self-monitoring of blood glucose forms an important part of the management of diabetes and the prevention of hyperglycaemia and hypoglycaemia. Current glucose monitoring methods either use needle-prick enzymatic glucose-meters or subcutaneous continuous glucose sensors (CGM) and thus, non-invasive glucose measurements could greatly improve the self-management of diabetes. A wide range of non-invasive sensing techniques have been reported, though achieving a level of precision comparable to invasive meters remains a challenge. Optical sensors, which utilise the interactions between glucose and light, offer the potential for non-invasive continuous sensing, allowing real-time monitoring of glucose levels, and a range of different optical sensing technologies have been proposed. These are primarily based upon optical absorption and scattering effects and include infrared spectroscopy, Raman spectroscopy and optical coherence tomography (OCT), with other optical techniques such as photoacoustic spectroscopy (PAS) and polarimetry also reported. This review aims to discuss the current progress behind the most reported optical glucose sensing methods, theory and current limitations of optical sensing methods and the future technology development required to achieve an accurate optical-based glucose monitoring device.


CIM Journal ◽  
2019 ◽  
Vol 10 (1) ◽  
Author(s):  
D. Beneteau ◽  
D. Milne ◽  
L. Feldman ◽  
G. Snell ◽  
A. Hyett

2010 ◽  
Author(s):  
Robert Siegrist ◽  
Ryan Oesterreich ◽  
Leanna Woods ◽  
Michele Crimi

2003 ◽  
Vol 2 (4) ◽  
pp. 443-443 ◽  
Author(s):  
Ty P. A. Ferré ◽  
Gerard J. Kluitenberg
Keyword(s):  

2003 ◽  
Vol 2 (4) ◽  
pp. 443
Author(s):  
Ty P. A. Ferré ◽  
Gerard J. Kluitenberg
Keyword(s):  

2004 ◽  
Vol 4 (2) ◽  
pp. 23-30
Author(s):  
K. Connell ◽  
M. Pope ◽  
K. Miller ◽  
J. Scheller ◽  
J. Pulz

Designing and conducting standardized microbiological method interlaboratory validation studies is challenging because most methods are manual, rather than instrument-based, and results from the methods are typically subjective. Determinations of method recovery, in particular, are problematic, due to difficulties in assessing the true spike amount. The standardization and validation process used for the seven most recent USEPA 1600-series pathogen monitoring methods has begun to address these challenges. A staged development process was used to ensure that methods were adequately tested and standardized before resources were dedicated to interlaboratory validation. The interlaboratory validation studies for USEPA Method 1622, for Cryptosporidium, USEPA Method 1601 for coliphage, and USEPA Method 1605 for Aeromonas assessed method performance using different approaches, due the differences in the nature of the target analytes and the data quality needs of each study. However, the use of enumerated spikes in all of the studies allowed method recovery and precision to be assessed, and also provided the data needed to establish quantitative quality control criteria for the methods.


Micromachines ◽  
2020 ◽  
Vol 11 (1) ◽  
pp. 72 ◽  
Author(s):  
Da-Quan Yang ◽  
Bing Duan ◽  
Xiao Liu ◽  
Ai-Qiang Wang ◽  
Xiao-Gang Li ◽  
...  

The ability to detect nanoscale objects is particular crucial for a wide range of applications, such as environmental protection, early-stage disease diagnosis and drug discovery. Photonic crystal nanobeam cavity (PCNC) sensors have attracted great attention due to high-quality factors and small-mode volumes (Q/V) and good on-chip integrability with optical waveguides/circuits. In this review, we focus on nanoscale optical sensing based on PCNC sensors, including ultrahigh figure of merit (FOM) sensing, single nanoparticle trapping, label-free molecule detection and an integrated sensor array for multiplexed sensing. We believe that the PCNC sensors featuring ultracompact footprint, high monolithic integration capability, fast response and ultrahigh sensitivity sensing ability, etc., will provide a promising platform for further developing lab-on-a-chip devices for biosensing and other functionalities.


Sign in / Sign up

Export Citation Format

Share Document