Development of a validated liquid chromatographic method for the quality control of Prunellae Spica: Determination of triterpenic acids

2009 ◽  
Vol 633 (2) ◽  
pp. 271-277 ◽  
Author(s):  
Mi Kyoung Lee ◽  
Young Min Ahn ◽  
Kang Ro Lee ◽  
Jee H. Jung ◽  
Ok-Sang Jung ◽  
...  
2020 ◽  
Vol 16 (8) ◽  
pp. 1037-1051
Author(s):  
Ehab Farouk Elkady ◽  
Marwa Ahmed Fouad ◽  
Abdulgabar A. Ezzy Faquih

Background: Atenolol is a selective beta 1 blocker that can be used alone or in combination with hydrochlorothiazide or with chlorthalidone for the treatment of hypertension and prevention from a heart attack. Objective: The main target of this work was to improve modern, easy, accurate and selective liquid chromatographic method (RP-HPLC) for the determination of these drugs in the presence of their degradation products. These methods can be used as analytical gadgets in quality control laboratories for a routine examination. Methods: In this method, the separation was accomplished through an Inertsil® ODS-3V C18 column (250 mm x 4.6 mm, 5 μm), the mobile phase used was 25 mM aqueous potassium dihydrogen orthophosphate solution adjusted to pH 6.8 by using 0.1M sodium hydroxide and acetonitrile (77 : 23, v/v), the flow rate used was 1 ml/min and detection was achieved at 235 nm using UV. Results: All peaks were sharp and well separated, the retention times were atenolol degradation (ATN Deg.) 2.311 min, atenolol (ATN) 2.580 min, hydrochlorothiazide degradation (HCT Deg.) 5.890 min, hydrochlorothiazide (HCT) 7.016 min, chlorthalidone degradation CTD Deg 8.018 min and chlorthalidone (CTD) 14.972 min. Linearity was obtained and the range of concentrations was 20- 160 μg/ml for atenolol, 10-80 μg/ml for hydrochlorothiazide and 10-80 μg/ml for chlorthalidone. According to ICH guidelines, method validation was accomplished, these methods include linearity, accuracy, selectivity, precision and robustness. Conclusion: The optimized method demonstrated to be specific, robust and accurate for the quality control of the cited drugs in pharmaceutical dosage forms.


2000 ◽  
Vol 83 (4) ◽  
pp. 789-792 ◽  
Author(s):  
Ehab A Abourashed ◽  
Ikhlas A Khan

Abstract The migraine prophylactic herb feverfew (Tanacetum parthenium L.) is marketed in the United States in a variety of forms and compositions. Although its therapeutic efficacy is still uncertain, the sesquiterpene lactone parthenolide is the constituent recommended to be measured for quality control of feverfew preparations. A validated liquid chromatographic method was developed and used to estimate parthenolide in a number of U.S. feverfew market products formulated as capsules, tablets, or crude powder. The method uses a Lichrosphere 5 C18 column, a mobile phase consisting of 50mM NaH2PO4 in H2O (solvent A), and CH3CN–MeOH (90 + 10, v/v; solvent B). Elution was run at a flow rate of 1.0 mL/min with a linear gradient of 50–15% A in B over 20 min and UV detection at 210 nm. The correlation coefficient for the calibration curve was 0.9999 over the range of 0.00–0.400 mg/mL. Overall recovery of parthenolide was 103.1%.


2019 ◽  
Vol 15 (6) ◽  
pp. 635-641
Author(s):  
Nadia M. Mostafa ◽  
Ghada M. Elsayed ◽  
Nagiba Y. Hassan ◽  
Dina A. El Mously

Background:The concept of green analytical chemistry prevails due to the growing environmental pollution.Objective:Our attempts are to develop simple and eco-friendly method which is non-harmful to the environment by producing minimal waste. In this context, a green liquid chromatographic method was applied for the simultaneous determination of chlorpheniramine maleate, pseudoephedrine hydrochloride and propyphenazone in their combined dosage form.Methods:Separation was carried out using X select HSS RP C18 analytical column (250 × 4.6 mm, 5μm) using methanol - 0.02 M phosphate buffer pH 3 - triethylamine (60:40: 0.1, by volume) as a mobile phase. The separated peaks were detected at 215 nm at a flow rate 1.0 mL/min.Results:Quantification was done over the concentration ranges of 1-25 µg/mL for chlorpheniramine maleate, 5-35 µg/mL for pseudoephedrine hydrochloride and 10-120 µg/mL for propyphenazone. The suggested method was validated with regard to linearity, accuracy and precision according to the International Conference on Harmonization guidelines with good results.Conclusion:It could be used as a safer alternative for routine analysis of the mentioned drugs in quality control laboratories.


Sign in / Sign up

Export Citation Format

Share Document