A sensitive colorimetric aptasensor based on trivalent peroxidase-mimic DNAzyme and magnetic nanoparticles

2018 ◽  
Vol 1018 ◽  
pp. 86-93 ◽  
Author(s):  
Shuwen Liu ◽  
Naihan Xu ◽  
Chunyan Tan ◽  
Wei Fang ◽  
Ying Tan ◽  
...  
RSC Advances ◽  
2016 ◽  
Vol 6 (38) ◽  
pp. 32308-32318 ◽  
Author(s):  
Anindita Roy ◽  
Ramkrishna Sahoo ◽  
Chaiti Ray ◽  
Soumen Dutta ◽  
Tarasankar Pal

The peroxidase-mimicking property of the soft template mediated phase selective α- and γ-Fe2O3 magnetic nanoparticles allows colorimetric sensing for thioglycolic acid down to μM level.


2011 ◽  
Vol 47 (38) ◽  
pp. 10785 ◽  
Author(s):  
Wenbing Shi ◽  
Xiaodan Zhang ◽  
Shaohui He ◽  
Yuming Huang

RSC Advances ◽  
2021 ◽  
Vol 11 (45) ◽  
pp. 28375-28380
Author(s):  
Ke Liu ◽  
Jiaxing Su ◽  
Jiangong Liang ◽  
Yuan Wu

Schematic illustration of glucose detection with glucose oxidase (GOx) and mMnFe2O4 MNPs-catalyzed system.


PIERS Online ◽  
2009 ◽  
Vol 5 (3) ◽  
pp. 231-234 ◽  
Author(s):  
Tsung-Han Tsai ◽  
Long-Sheng Kuo ◽  
Ping-Hei Chen ◽  
Chin-Ting Yang

2017 ◽  
Author(s):  
Bo Tian ◽  
Peter Svedlindh ◽  
Mattias Strömberg ◽  
Erik Wetterskog

In this work, we demonstrate for the first time, a ferromagnetic resonance (FMR) based homogeneous and volumetric biosensor for magnetic label detection. Two different isothermal amplification methods, <i>i.e.</i>, rolling circle amplification (RCA) and loop-mediated isothermal amplification (LAMP) are adopted and combined with a standard electron paramagnetic resonance (EPR) spectrometer for FMR biosensing. For RCA-based FMR biosensor, binding of RCA products of a synthetic Vibrio cholerae target DNA sequence gives rise to the formation of aggregates of magnetic nanoparticles. Immobilization of nanoparticles within the aggregates leads to a decrease of the net anisotropy of the system and a concomitant increase of the resonance field. A limit of detection of 1 pM is obtained with an average coefficient of variation of 0.16%, which is superior to the performance of other reported RCA-based magnetic biosensors. For LAMP-based sensing, a synthetic Zika virus target oligonucleotide is amplified and detected in 20% serum samples. Immobilization of magnetic nanoparticles is induced by their co-precipitation with Mg<sub>2</sub>P<sub>2</sub>O<sub>7</sub> (a by-product of LAMP) and provides a detection sensitivity of 100 aM. The fast measurement, high sensitivity and miniaturization potential of the proposed FMR biosensing technology makes it a promising candidate for designing future point-of-care devices.<br>


2020 ◽  
Vol 84 (11) ◽  
pp. 1362-1365
Author(s):  
A. V. Komina ◽  
R. N. Yaroslavtsev ◽  
Y. V. Gerasimova ◽  
S. V. Stolyar ◽  
I. A. Olkhovsky ◽  
...  

2018 ◽  
pp. 17-28
Author(s):  
Hwunjae Lee ◽  
◽  
SangBock Lee ◽  
Geahwan Jin ◽  
Sergey NETESOV ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document