scholarly journals Prognostic value of 6-minute walk test and cardiopulmonary exercise test in acute heart failure (from the ESCAPE trial)

Author(s):  
Hesham R. Omar ◽  
Maya Guglin
2016 ◽  
Vol 31 (suppl_1) ◽  
pp. i476-i477
Author(s):  
Wioletta Dziubek ◽  
Mariusz Kusztal ◽  
Katarzyna Bulińska ◽  
Bartosz Ochmann ◽  
Łukasz Rogowski ◽  
...  

2019 ◽  
Vol 35 (10) ◽  
pp. S113-S114
Author(s):  
A. Lebel ◽  
A. Auclair ◽  
M. Pettigrew ◽  
M. Thibault ◽  
V. Ménard-Cholette ◽  
...  

OALib ◽  
2018 ◽  
Vol 05 (09) ◽  
pp. 1-11
Author(s):  
Dakaboué Germain Mandi ◽  
Dangwé Temoua Na?bé ◽  
Joel Bamouni ◽  
Rélwendé Aristide Yaméogo ◽  
Yibar Kambiré ◽  
...  

Author(s):  
Vivian Z. Tan ◽  
Meredith Q. Lee ◽  
Daryl L. Wong ◽  
Katherin S. Huang ◽  
Melissa Y. Chan ◽  
...  

Background/Objective: To date, a validated Chinese (Mandarin) six-minute walk test (6MWT) translated instruction is not available. Translation of the Chinese 6MWT instruction is done in an ad hoc manner within the Chinese-speaking populations. This study aimed to develop a set of valid and reliable Chinese (Mandarin) instructions of the 6MWT. Methods: Translation was performed from the original English instruction via the recommended “Process of translation and adaptation of instruments” by the World Health Organization to generate the Chinese instructions. The Chinese instructions were tested with 52 healthy adult participants for its validity. Each participant underwent three 6MWTs and a cardiopulmonary exercise test. Randomization allowed participants to undergo the walk test in both the original English and the new Chinese instructions. Face and content validity, intra-rater and inter-rater reliability of the Chinese instructions of the 6MWT were established through the translation process. Criterion validity was established by analyzing the results of the 6MWT and cardiopulmonary exercise test. Results: Intraclass correlation coefficient for inter-rater reliability was excellent ([Formula: see text], 95% confidence [Formula: see text]–1.000). Similarly, the intra-rater reliability across the three raters was high (R1: [Formula: see text], 95% confidence interval [Formula: see text]–1.000; R2: [Formula: see text], 95% [Formula: see text]–1.000; R3: [Formula: see text], 95% [Formula: see text]–1.000). The 6-min walk distances collected from the Chinese and English instructed trials correlated positively with the maximal oxygen consumption ([Formula: see text], [Formula: see text]; [Formula: see text], [Formula: see text]). Conclusion: This is the first study to develop and validate the Chinese (Mandarin) instructions of the 6MWT, and the translation is as reliable and valid as the original English instructions.


Sign in / Sign up

Export Citation Format

Share Document