Bi-nonlinear vibration model of tubing string in oil & gas well and its experimental verification

2020 ◽  
Vol 81 ◽  
pp. 50-69 ◽  
Author(s):  
Jun Liu ◽  
Xiaoqiang Guo ◽  
Guorong Wang ◽  
Qingyou Liu ◽  
Dake Fang ◽  
...  
2020 ◽  
pp. 102468
Author(s):  
Xiaoqiang Guo ◽  
Jun Liu ◽  
Guorong Wang ◽  
Liming Dai ◽  
Dake Fang ◽  
...  

SPE Journal ◽  
2016 ◽  
Vol 21 (04) ◽  
pp. 1470-1476 ◽  
Author(s):  
Ebrahim Hajidavalloo ◽  
Saeed Alidadi Dehkohneh

Summary When a blowout oil/gas well catches fire, usually a flow tube is used to detach the fire from the wellhead and provide appropriate conditions for operating team members to approach the well and install the blowout-preventer (BOP) cap. Using the flow tube above the wellhead creates powerful suction around the tube that may jeopardize the safety of crew members. To reduce the power of suction around the well, a new perforated flow tube instead of simple flow tube was introduced. To understand the effect of this new type of flow tube, modeling and simulation of the flow field around the blowout well were performed for both simple and perforated types of flow tube with Fluent 6.3.26 (2003) and Gambit 2.3.16 (2003) softwares. Different parameters around the well mouth were compared in both designs. The results showed that using the perforated flow tube decreases the vacuum around the well by 33% compared with the simple flow tubes. Thus, application of the perforated flow tube can be recommended in well-control operations for safety measures.


2011 ◽  
Vol 284-286 ◽  
pp. 1049-1052 ◽  
Author(s):  
Zheng Fan ◽  
Wen Hong Li ◽  
Dong Li ◽  
Cun Ju Liu ◽  
Yu Luo ◽  
...  

The ability of IMC-80BH corrosion inhibitor is proven to be excellent in earlier indoor static and flowing evaluation and it is worthwhile to determine the inhibitor concentration to maintain the optimum concentration for the sake of effective gas well protection. A improved concentration determination method is aboratively investigated. The maximum absorption wavelengths, buffer solution, reaction time and additive dosage of chromogenic reagent XD are detected successively and the standard curve of liquid phase behaves better than oil gas. The sample verification demonstrates that such determination measurement is reliable and precise. The four representative gas wells including G8-7, S59, W26-5 and G49-6 in service are also determined. The determination result offered substantial basis to analyze and select appropriate inhibitor injection program and dosage.


2018 ◽  
Vol 94 (3) ◽  
pp. 2219-2241 ◽  
Author(s):  
Hui Li ◽  
Pengcheng Xue ◽  
Zhongwei Guan ◽  
Qingkai Han ◽  
Bangchun Wen

Sign in / Sign up

Export Citation Format

Share Document