Performance analysis of an ejector-assisted two-stage evaporation single-stage vapor-compression cycle

Author(s):  
Xiang Cao ◽  
Xingyu Liang ◽  
Liangliang Shao ◽  
Chunlu Zhang
2017 ◽  
Vol 74 ◽  
pp. 517-527 ◽  
Author(s):  
K. Megdouli ◽  
B.M. Tashtoush ◽  
E. Nahdi ◽  
M. Elakhdar ◽  
A. Mhimid ◽  
...  

2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Ryan Snodgrass ◽  
David Erickson

AbstractElastocaloric refrigerators are a promising alternative to the vapor compression cycle because they do not require refrigerants with high global warming potential. However, these coolers have yet to achieve temperatures low enough to — for example — be used as standard household refrigerators. We built one-stage, two-stage, and three-stage elastocaloric cooling systems to determine if staging of the elastocaloric effect could significantly expand temperature span. Our three-stage system achieved 1.5 times the maximum temperature span of our single-stage system, and produced the highest temperature span of any elastocaloric device to-date at 28.3 °C, where previously the record was 19.9 °C. Interestingly, we found that multistage systems can achieve equivalent temperature spans but at higher coefficients of performance compared to similarly-constructed single-stage systems.


Author(s):  
Rongliang Zhou ◽  
Juan Catano ◽  
Tiejun Zhang ◽  
John T. Wen ◽  
Greg J. Michna ◽  
...  

Steady-state modeling and analysis of a two-loop cooling system for high heat flux removal applications are studied. The system structure proposed consists of a primary pumped loop and a vapor compression cycle (VCC) as the secondary loop to which the pumped loop rejects heat. The pumped loop consists of evaporator, condenser, pump, and bladder liquid accumulator. The pumped loop evaporator has direct contact with the heat generating device and CHF must be higher than the imposed heat fluxes to prevent device burnout. The bladder liquid accumulator adjusts the pumped loop pressure level and, hence, the subcooling of the refrigerant to avoid pump cavitation and to achieve high critical heat flux (CHF) in the pumped loop evaporator. The vapor compression cycle of the two-loop cooling system consists of evaporator, liquid accumulator, compressor, condenser and electronic expansion valve. It is coupled with the pumped loop through a fluid-to-fluid heat exchanger that serves as both the vapor compression cycle evaporator and the pumped loop condenser. The liquid accumulator of the vapor compression cycle regulates the cycle active refrigerant charge and provides saturated vapor to the compressor at steady state. The heat exchangers are modeled with the mass, momentum, and energy balance equations. Due to the projected incorporation of microchannels in the pumped loop to enhance the heat transfer in heat sinks, the momentum equation, rarely seen in previous refrigeration system modeling efforts, is included to capture the expected significant microchannel pressure drop witnessed in previous experimental investigations. Electronic expansion valve, compressor, pump, and liquid accumulators are modeled as static components due to their much faster dynamics compared with heat exchangers. The steady-state model can be used for static system design that includes determining the total refrigerant charge in the vapor compression cycle and the pumped loop to accommodate the varying heat load, sizing of various components, and parametric studies to optimize the operating conditions for a given heat load. The effect of pumped loop pressure level, heat exchangers geometries, pumped loop refrigerant selection, and placement of the pump (upstream or downstream of the evaporator) are studied. The two-loop cooling system structure shows both improved coefficient of performance (COP) and CHF overthe single loop vapor compression cycle investigated earlier by authors for high heat flux removal.


Author(s):  
Yilin Du ◽  
Jan Muehlbauer ◽  
Jiazhen Ling ◽  
Vikrant Aute ◽  
Yunho Hwang ◽  
...  

A rechargeable personal air-conditioning (RPAC) device was developed to provide an improved thermal comfort level for individuals in inadequately cooled environments. This device is a battery powered air-conditioning system with the phase change material (PCM) for heat storage. The condenser heat is stored in the PCM during the cooling operation and is discharged while the battery is charged by using the vapor compression cycle as a thermosiphon loop. The conditioned air is discharged towards a single person through adjustable nozzle. The main focus of the current research was on the development of the cooling system. A 100 W cooling capacity prototype was designed, built, and tested. The cooling capacity of the vapor compression cycle measured was 165.6 W. The PCM was recharged in nearly 8 hours under thermosiphon mode. When this device is used in the controlled built environment, the thermostat setting can be increased so that building air conditioning energy can be saved by about 5–10%.


Sign in / Sign up

Export Citation Format

Share Document