scholarly journals Thoracic Endovascular Aortic Repair Including Total Debranching on Femoral Artery for Arch Rupture

2017 ◽  
Vol 104 (2) ◽  
pp. e123-e125
Author(s):  
Yu Inaba ◽  
Tsutomu Ito ◽  
Sachiko Hayashi ◽  
Tatsuo Takahashi ◽  
Takahiko Misumi ◽  
...  
2011 ◽  
Vol 25 (3) ◽  
pp. 340-344 ◽  
Author(s):  
Vahid Etezadi ◽  
Barry T. Katzen ◽  
James F. Benenati ◽  
Sara Alehashemi ◽  
Athanassios I. Tsoukas ◽  
...  

Vascular ◽  
2020 ◽  
pp. 170853812094966
Author(s):  
Ömer Çelik ◽  
Ahmet Anıl Şahin ◽  
Ahmet Güner ◽  
Ali Rıza Demir ◽  
Nedim Uzun ◽  
...  

Background While the percutaneous approach is increasingly preferred, suture-mediated closure devices have been put into clinical practice to close the femoral artery during procedures requiring a large-sized introducer. However, scar in the groin is considered a contraindication or an exclusion criterion for percutaneous procedures. The aim of our study was to investigate the outcomes and safety of Pro-Glide device as suture-mediated closure device in patients who underwent thoracic endovascular aortic repair with percutaneous femoral access ≥22 F who had previous groin intervention. Methods A total of 73 patients who underwent endovascular repair with percutaneous femoral access were retrospectively included in the study. Previous groin intervention was defined as history of open surgical access or large sheath insertion (>18 F) to femoral artery because of endovascular or valvular intervention. Patients were divided into two groups as who had previous groin intervention PGI (+) and had not PGI (−). Results A total of 73 patients [60 male (82.2%)] were included in the study. Seventeen patients had PGI, and 56 did not. When groups were compared in terms of sheath sizes, a significantly higher sheath sizes were used in PGI (+) patients (24.5 ± 1.1 F vs. 23.8 ± 0.9 F, p = 0.005). The overall success rate in the femoral approach with pre-close technique was statistically insignificant between two groups (94.1% vs. 96.4%, p = 0.55). One patient in PGI (+) group and two patients in PGI (−) had technical failure for percutaneous femoral approach. One patient (5.9%) in PGI (+) group and one patient (1.8%) in PGI (−) group had femoral complications after the procedures; however, there was no significant difference between the groups in terms of complications (5.9% vs. 1.8%, p = 0.13). Conclusion Pro-Glide device may be a safe and less invasive method for femoral access in patients with PGI and might not be considered as a contraindication for patients with history of PGI.


2020 ◽  
Vol 27 (5) ◽  
pp. 801-804
Author(s):  
Catharina Gronert ◽  
Nikolaos Tsilimparis ◽  
Giuseppe Panuccio ◽  
Ahmed Eleshra ◽  
Fiona Rohlffs ◽  
...  

Purpose: To report a case of chronic intermittent spinal cord ischemia (SCI) after thoracic endovascular aortic repair (TEVAR) and its successful treatment using hypogastric artery stenting. Case Report: A 79-year-old patient presented in May 2013 with a thoracic aortic aneurysm (TAA) and a contained rupture. He urgently underwent TEVAR that covered 274 mm of descending thoracic aorta without immediate postoperative signs of acute SCI. At 3-month follow-up, he reported repeating incidents of sudden lower extremity weakness leading to a fall with a humerus fracture. A neurological consultation revealed the tentative diagnosis of intermittent SCI caused by TEVAR and initially recommended a conservative approach. During the following year there was no clinical improvement of the symptoms. Computed tomography angiography showed a high-grade stenosis of the right hypogastric artery, which was stented in November 2014 to improve the collateral network of spinal cord perfusion. Following treatment, the patient had no further neurological symptoms; at 32 months after the reintervention, the imaging follow-up documented a patent stent and continued exclusion of the TAA. Conclusion: Intermittent neurological symptoms after TEVAR should be suspected as chronic intermittent SCI. The improvement of collateral networks of the spinal cord by revascularization of the hypogastric artery is a viable treatment option.


2021 ◽  
Vol 55 (4) ◽  
pp. 355-360
Author(s):  
Sally H. J. Choi ◽  
Gary K. Yang ◽  
Keith Baxter ◽  
Joel Gagnon

Background: Adequate seal for thoracic endovascular aortic repair (TEVAR) commonly requires landing in zone 2, but can prove to be challenging due to the tortuous and angulated anatomy of the region. Objectives: Our objective was to determine the proximal landing accuracy of zone 2-targeted TEVARs following carotid-subclavian revascularization (CSR) and its impact on clinical outcomes. Methods: Retrospective review of patients that underwent CSR for zone 2 endograft delivery at a tertiary institute between January 2008 and March 2018 was conducted. Technical outcomes were assessed by examining the incidence of intraoperative corrective maneuvers, 1a endoleaks and reinterventions. Distance to target and incidence of LSA stump filling were examined as radiographic markers of landing accuracy. Results: Zone 2-targeted TEVAR with CSR was performed in 53 patients for treatment of dissections (49%), aneurysms (30%) or trauma (21%). Nine (17%) cases required intraoperative corrective procedures: 5 (9%) proximal cuffs due to type 1a endoleak and 4 (8%) left common carotid artery (LCCA) stenting due to inadvertent coverage. Cases performed using higher resolution hybrid fluoroscopy machine compared to mobile C-arm were associated with increased proximal cuff use (OR 8.8; 95% CI 1.2-62.4). Average distance between the proximal edge of the covered graft to LCCA was 8 ± 1 mm and larger distances were not associated with higher rates of 1a endoleak. Twenty-eight (53%) cases of antegrade LSA stump filling were noted on follow-up imaging, but were not associated with higher rates of reinterventions (OR 0.8, 95% CI [0.2-4.6]). Three (6%) patients had a stroke within 30 days and 4 (8%) patients expired within 1 month. Intraoperative corrective maneuvers, post-operative 1a endoleak and reinterventions were not associated with higher rates of stroke or mortality. Conclusion: Using current endografts and imaging modalities, zone 2-targeted TEVARs have suboptimal technical accuracy.


Sign in / Sign up

Export Citation Format

Share Document