Porous silicon membrane-modified electrodes for label-free voltammetric detection of MS2 bacteriophage

2016 ◽  
Vol 80 ◽  
pp. 47-53 ◽  
Author(s):  
Nekane Reta ◽  
Andrew Michelmore ◽  
Christopher Saint ◽  
Beatriz Prieto-Simón ◽  
Nicolas H. Voelcker
2008 ◽  
Vol 93 (16) ◽  
pp. 161109 ◽  
Author(s):  
Guoguang Rong ◽  
Judson D. Ryckman ◽  
Raymond L. Mernaugh ◽  
Sharon M. Weiss

2019 ◽  
Vol 15 (4) ◽  
pp. 502-510 ◽  
Author(s):  
Hakan Karadeniz ◽  
Arzum Erdem

Background: Anthrax Lethal Factor (ANT) is the dominant virulence factor produced by B. anthracis and is the major cause of death of infected animals. In this paper, pencil graphite electrodes GE were modified with single-walled and multi-walled carbon nanotubes (CNTs) for the detection of hybridization related to the ANT DNA for the first time in the literature. Methods: The electrochemical monitoring of label-free DNA hybridization related to ANT DNA was explored using both SCNT and MCNT modified PGEs with differential pulse voltammetry (DPV). The performance characteristics of ANT-DNA hybridization on disposable GEs were explored by measuring the guanine signal in terms of optimum analytical conditions; the concentration of SCNT and MCNT, the concentrations of probe and target, and also the hybridization time. Under the optimum conditions, the selectivity of probe modified electrodes was tested and the detection limit was calculated. Results: The selectivity of ANT probes immobilized onto MCNT-GEs was tested in the presence of hybridization of probe with NC no response was observed and with MM, smaller responses were observed in comparison to full-match DNA hybridization case. Even though there are unwanted substituents in the mixture samples containing both the target and NC in the ratio 1:1 and both the target and MM in the ratio 1:1, it has been found that ANT probe immobilized CNT modified graphite sensor can also select its target by resulting with 20.9% decreased response in comparison to the one measured in the case of full-match DNA hybridization case Therefore, it was concluded that the detection of direct DNA hybridization was performed by using MCNT-GEs with an acceptable selectivity. Conclusion: Disposable SCNT/MCNT modified GEs bring some important advantages to our assay including easy use, cost-effectiveness and giving a response in a shorter time compared to unmodified PGE, carbon paste electrode and glassy carbon electrode developed for electrochemical monitoring of DNA hybridization. Consequently, the detection of DNA hybridization related to the ANT DNA by MCNT modified sensors was performed by using lower CNT, probe and target concentrations, in a shorter hybridization time and resulting in a lower detection limit according to the SCNT modified sensors. In conclusion, MCNT modified sensors can yield the possibilities leading to the development of nucleic acid sensors platforms for the improvement of fast and cost-effective detection systems with respect to DNA chip technology.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Rozita Abolhasan ◽  
Balal Khalilzadeh ◽  
Hadi Yousefi ◽  
Sahar Samemaleki ◽  
Forough Chakari-Khiavi ◽  
...  

AbstractIn the present article, we developed a highly sensitive label-free electrochemical immunosensor based on NiFe-layered double hydroxides (LDH)/reduced graphene oxide (rGO)/gold nanoparticles modified glassy carbon electrode for the determination of receptor tyrosine kinase-like orphan receptor (ROR)-1. In this electrochemical immunoassay platform, NiFe-LDH/rGO was used due to great electron mobility, high specific surface area and flexible structures, while Au nanoparticles were prepared and coated on the modified electrodes to improve the detection sensitivity and ROR1 antibody immobilizing (ROR1Ab). The modification procedure was approved by using cyclic voltammetry and differential pulse voltammetry based on the response of peak current to the step by step modifications. Under optimum conditions, the experimental results showed that the immunosensor revealed a sensitive response to ROR1 in the range of 0.01–1 pg mL−1, and with a lower limit of quantification of 10 attogram/mL (10 ag mL−1). Furthermore, the designed immunosensor was applied for the analysis of ROR1 in several serum samples of chronic lymphocytic leukemia suffering patients with acceptable results, and it also exhibited good selectivity, reproducibility and stability.


2008 ◽  
Author(s):  
Xiao-yi Lü ◽  
Tao Xue ◽  
Zhen-hong Jia ◽  
Hua-wei Shao ◽  
Shi-bin Hou ◽  
...  

Small ◽  
2016 ◽  
Vol 13 (6) ◽  
pp. 1603135 ◽  
Author(s):  
Yiqiu Xia ◽  
Yi Tang ◽  
Xu Yu ◽  
Yuan Wan ◽  
Yizhu Chen ◽  
...  

2019 ◽  
Vol 19 (9) ◽  
pp. 3276-3281 ◽  
Author(s):  
David Martin-Sanchez ◽  
Salvador Ponce-Alcantara ◽  
Jaime Garcia-Ruperez

Sign in / Sign up

Export Citation Format

Share Document