Metal-organic frameworks derived low-crystalline NiCo2S4/Co3S4 nanocages with dual heterogeneous interfaces for high-performance supercapacitors

Author(s):  
Zixin Jia ◽  
Youning Wang ◽  
Jiaqi Chen ◽  
Zhijie Caoc Shugang Pan ◽  
Yan Zhou ◽  
...  
2021 ◽  
Author(s):  
Dae-Woon Lim ◽  
Hiroshi Kitagawa

Since the transition of energy platforms, the proton-conductive metal–organic frameworks (MOFs) exhibiting high performance have been extensively investigated with rational strategies for their potential application in solid-state electrolytes.


Author(s):  
Jian Xiong ◽  
Ailin Li ◽  
Ye Liu ◽  
Liming Wang ◽  
Xiaohong Qin ◽  
...  

Integrating metal-organic frameworks (MOFs) into flexible polymeric matrices can improve their practical processibility and enlarge industrial applications greatly. However, current methods suffer from the serious aggregation of MOFs, low MOF...


Molecules ◽  
2018 ◽  
Vol 23 (11) ◽  
pp. 2869 ◽  
Author(s):  
Iván Taima-Mancera ◽  
Priscilla Rocío-Bautista ◽  
Jorge Pasán ◽  
Juan Ayala ◽  
Catalina Ruiz-Pérez ◽  
...  

Four metal-organic frameworks (MOFs), specifically UiO-66, UiO-66-NH2, UiO-66-NO2, and MIL-53(Al), were synthesized, characterized, and used as sorbents in a dispersive micro-solid phase extraction (D-µSPE) method for the determination of nine pollutants of different nature, including drugs, phenols, polycyclic aromatic hydrocarbons, and personal care products in environmental waters. The D-µSPE method, using these MOFs as sorbents and in combination with high-performance liquid chromatography (HPLC) and diode-array detection (DAD), was optimized. The optimization study pointed out to UiO-66-NO2 as the best MOF to use in the multi-component determination. Furthermore, the utilization of isoreticular MOFs based on UiO-66 with the same topology but different functional groups, and MIL-53(Al) to compare with, allowed us for the first time to evaluate the influence of such functionalization of the ligand with regards to the efficiency of the D-µSPE-HPLC-DAD method. Optimum conditions included: 20 mg of UiO-66-NO2 MOF in 20 mL of the aqueous sample, 3 min of agitation by vortex and 5 min of centrifugation, followed by the use of only 500 µL of acetonitrile as desorption solvent (once the MOF containing analytes was separated), 5 min of vortex and 5 min of centrifugation. The validation of the D-µSPE-HPLC-DAD method showed limits of detection down to 1.5 ng·L−1, average relative recoveries of 107% for a spiked level of 1.50 µg·L−1, and inter-day precision values with relative standard deviations lower than 14%, for the group of pollutants considered.


2019 ◽  
Vol 30 (3) ◽  
pp. 605-609 ◽  
Author(s):  
Shaofei Zhao ◽  
Lizhen Zeng ◽  
Gao Cheng ◽  
Lin Yu ◽  
Huaqiang Zeng

Sign in / Sign up

Export Citation Format

Share Document