Multidimensional gas chromatography for the detailed PIONA analysis of heavy naphtha: Hyphenation of an olefin trap to comprehensive two-dimensional gas chromatography

2005 ◽  
Vol 1090 (1-2) ◽  
pp. 116-125 ◽  
Author(s):  
Colombe Vendeuvre ◽  
Fabrice Bertoncini ◽  
Didier Espinat ◽  
Didier Thiébaut ◽  
Marie-Claire Hennion
2013 ◽  
Vol 6 (1) ◽  
pp. 133-140 ◽  
Author(s):  
Alexandra Pažitná ◽  
Nikoleta Jánošková ◽  
Ivan Špánik

Abstract This review deals with overview of methods of multidimensional gas chromatography (MDGC), the classical meaning- conventional heart-cut MDGC, and the comprehensive two-dimensional gas chromatography (GC×GC). MDGC is widely used because it increases required separation efficiency, which cannot be achieved by one-dimensional gas chromatography. Selected applications in food quality and safety, monitoring of environment, food authentication are summarized. This review summarizes the advances and applications of MDGC that have been published over last 10 years.


2021 ◽  
Vol 13 (1) ◽  
pp. 124-132
Author(s):  
Pannipa Janta ◽  
Duangkamol Pinyo ◽  
Yamonporn Yodta ◽  
Porames Vasasiri ◽  
Meinolf Weidenbach ◽  
...  

Comprehensive heart-cut multidimensional gas chromatography (CH/C MDGC) without a cryogenic trapping device was developed with an approach for calculation of first and second dimensional retention indices (1I and 2I).


2014 ◽  
Vol 32 (10) ◽  
pp. 1144
Author(s):  
Ting TONG ◽  
Wanfeng ZHANG ◽  
Donghao LI ◽  
Jinhua ZHAO ◽  
Zhenyang CHANG ◽  
...  

1982 ◽  
Vol 14 (4-5) ◽  
pp. 59-71 ◽  
Author(s):  
L H Keith ◽  
R C Hall ◽  
R C Hanisch ◽  
R G Landolt ◽  
J E Henderson

Two new methods have been developed to analyze for organic pollutants in water. The first, two-dimensional gas chromatography, using post detector peak recycling (PDPR), involves the use of a computer-controlled gas Chromatograph to selectively trap compounds of interest and rechromatograph them on a second column, recycling them through the same detector again. The second employs a new detector system, a thermally modulated electron capture detector (TMECD). Both methods were used to demonstrate their utility by applying them to the analysis of a new class of potentially ubiquitous anthropoaqueous pollutants in drinking waters- -haloacetonitriles. These newly identified compounds are produced from certain amino acids and other nitrogen-containing compounds reacting with chlorine during the disinfection stage of treatment.


Sign in / Sign up

Export Citation Format

Share Document