Prediction of liquid chromatographic retention time using quantitative structure-retention relationships to assist non-targeted identification of unknown metabolites of phthalates in human urine with high-resolution mass spectrometry

2020 ◽  
Vol 1634 ◽  
pp. 461691
Author(s):  
Sherif Meshref ◽  
Yan Li ◽  
Yong-Lai Feng
Author(s):  
Gabriel L. Streun ◽  
Andrea E. Steuer ◽  
Lars C. Ebert ◽  
Akos Dobay ◽  
Thomas Kraemer

Abstract Objectives Urine sample manipulation including substitution, dilution, and chemical adulteration is a continuing challenge for workplace drug testing, abstinence control, and doping control laboratories. The simultaneous detection of sample manipulation and prohibited drugs within one single analytical measurement would be highly advantageous. Machine learning algorithms are able to learn from existing datasets and predict outcomes of new data, which are unknown to the model. Methods Authentic human urine samples were treated with pyridinium chlorochromate, potassium nitrite, hydrogen peroxide, iodine, sodium hypochlorite, and water as control. In total, 702 samples, measured with liquid chromatography coupled to quadrupole time-of-flight mass spectrometry, were used. After retention time alignment within Progenesis QI, an artificial neural network was trained with 500 samples, each featuring 33,448 values. The feature importance was analyzed with the local interpretable model-agnostic explanations approach. Results Following 10-fold cross-validation, the mean sensitivity, specificity, positive predictive value, and negative predictive value was 88.9, 92.0, 91.9, and 89.2%, respectively. A diverse test set (n=202) containing treated and untreated urine samples could be correctly classified with an accuracy of 95.4%. In addition, 14 important features and four potential biomarkers were extracted. Conclusions With interpretable retention time aligned liquid chromatography high-resolution mass spectrometry data, a reliable machine learning model could be established that rapidly uncovers chemical urine manipulation. The incorporation of our model into routine clinical or forensic analysis allows simultaneous LC-MS analysis and sample integrity testing in one run, thus revolutionizing this field of drug testing.


2015 ◽  
Vol 7 (18) ◽  
pp. 7697-7706 ◽  
Author(s):  
Juri Leonhardt ◽  
Thorsten Teutenberg ◽  
Jochen Tuerk ◽  
Michael P. Schlüsener ◽  
Thomas A. Ternes ◽  
...  

The interest in two-dimensional liquid chromatography separations is growing every year together with the number of open questions on the benefits.


2020 ◽  
Author(s):  
Ken Liu ◽  
Choon Lee ◽  
Grant Singer ◽  
Michael Woodworth ◽  
Thomas Ziegler ◽  
...  

Abstract Advances in genomics have revealed many of the genetic underpinnings of human disease, but exposomics methods are currently inadequate to obtain a similar level of understanding of environmental contributions to human disease. Exposomics methods are limited by low abundance of xenobiotic metabolites and lack of authentic standards, which precludes identification using solely mass spectrometry-based criteria. Here, we develop and validate a method for enzymatic generation of xenobiotic metabolites for use with high-resolution mass spectrometry (HRMS) for chemical identification. Generated xenobiotic metabolites were used to confirm identities of respective metabolites in mice and human samples based upon accurate mass, retention time and co-occurrence with related xenobiotic metabolites. The results establish a generally applicable enzyme-based identification (EBI) for mass spectrometry identification of xenobiotic metabolites.


Sign in / Sign up

Export Citation Format

Share Document