A Generic and Rapid Analytical Method for Comprehensive Determination of Veterinary Drugs and Other Contaminants in Raw Honey

2022 ◽  
pp. 462828
Author(s):  
Jia Zhan ◽  
Xi-zhi Shi ◽  
Yi Ding ◽  
Ning Qian ◽  
Jie Zhou ◽  
...  
2020 ◽  
Vol 0 (4) ◽  
pp. 29-32
Author(s):  
B.M. GAREEV ◽  
◽  
A.M. ABDRAKHMANOV ◽  
G.L. SHARIPOV ◽  
◽  
...  

The photoluminescence of carbon quantum dots synthesized from natural honey and mixtures of honey and sugar has been studied. An increase in the sugar content leads to a decrease in the photoluminescence intensity without changing the shape of the luminescence spectrum of these quantum dots aqueous solutions, which is associated with a decrease in the yield of their synthesis in the sugar presence. The discovered effect can be used to detect sugar in honey. When examining five different market samples of flower honey using this method, two of them showed a significant decrease in the photoluminescence intensity. A laboratory test for compliance with GOST 19792-2017 Standard requirements established an excess of the sucrose content in these samples. Luminescent determination of sugar in honey does not require complicated equipment and can be used to develop a new analytical method for determining the sugar content in counterfeit natural honey.


Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4842
Author(s):  
Waldemar Kamiński

Nowadays, hydrostatic levelling is a widely used method for the vertical displacements’ determinations of objects such as bridges, viaducts, wharfs, tunnels, high buildings, historical buildings, special engineering objects (e.g., synchrotron), sports and entertainment halls. The measurements’ sensors implemented in the hydrostatic levelling systems (HLSs) consist of the reference sensor (RS) and sensors located on the controlled points (CPs). The reference sensor is the one that is placed at the point that (in theoretical assumptions) is not a subject to vertical displacements and the displacements of controlled points are determined according to its height. The hydrostatic levelling rule comes from the Bernoulli’s law. While using the Bernoulli’s principle in hydrostatic levelling, the following components have to be taken into account: atmospheric pressure, force of gravity, density of liquid used in sensors places at CPs. The parameters mentioned above are determined with some mean errors that influence on the accuracy assessment of vertical displacements. In the subject’s literature, there are some works describing the individual accuracy analyses of the components mentioned above. In this paper, the author proposes the concept of comprehensive determination of mean error of vertical displacement (of each CPs), calculated from the mean errors’ values of components dedicated for specific HLS. The formulas of covariances’ matrix were derived and they enable to make the accuracy assessment of the calculations’ results. The author also presented the subject of modelling of vertical displacements’ gained values. The dependences, enabling to conduct the statistic tests of received model’s parameters, were implemented. The conducted tests make it possible to verify the correctness of used theoretical models of the examined object treated as the rigid body. The practical analyses were conducted for two simulated variants of sensors’ connections in HLS. Variant no. I is the sensors’ serial connection. Variant no. II relies on the connection of each CPs with the reference sensor. The calculations’ results show that more detailed value estimations of the vertical displacements can be obtained using variant no. II.


Author(s):  
Mohamed H. EL-Saeid ◽  
Ashraf S. Hassanin ◽  
Abdulqader Y. Bazeyad ◽  
Norhan M. Hamza
Keyword(s):  

2021 ◽  
Vol 164 ◽  
pp. 105964
Author(s):  
Amira F. El-Yazbi ◽  
Yasmine Khalifa ◽  
Mohammed A.W. Elkhatib ◽  
Ahmed F. El-Yazbi

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Juha I. Peltonen ◽  
Touko Kaasalainen ◽  
Mika Kortesniemi

Abstract Background Cone-beam computed tomography (CBCT) has become an increasingly important medical imaging modality in orthopedic operating rooms. Metal implants and related image artifacts create challenges for image quality optimization in CBCT. The purpose of this study was to develop a robust and quantitative method for the comprehensive determination of metal artifacts in novel CBCT applications. Methods The image quality of an O-arm CBCT device was assessed with an anthropomorphic pelvis phantom in the presence of metal implants. Three different kilovoltage and two different exposure settings were used to scan the phantom both with and without the presence of metal rods. Results The amount of metal artifact was related to the applied CBCT imaging protocol parameters. The size of the artifact was moderate with all imaging settings. The highest applied kilovoltage and exposure level distinctly increased artifact severity. Conclusions The developed method offers a practical and robust way to quantify metal artifacts in CBCT. Changes in imaging parameters may have nonlinear effects on image quality which are not anticipated based on physics.


Sign in / Sign up

Export Citation Format

Share Document