scholarly journals The dataset on the clipped cerebral aneurysm and their radiological findings in three-dimensional computed tomography, time-of-flight magnetic resonance angiography (TOF-MRA), and Pointwise Encoding Time Reduction with Radial Acquisition (PETRA)-MRA

Data in Brief ◽  
2021 ◽  
Vol 35 ◽  
pp. 106874
Author(s):  
Akihiro Nishikawa ◽  
Masahito Katsuki ◽  
Yukinari Kakizawa ◽  
Naomichi Wada ◽  
Yasunaga Yamamoto ◽  
...  
Neurosurgery ◽  
2020 ◽  
Author(s):  
Sung-Hye You ◽  
Byungjun Kim ◽  
Kyung-Sook Yang ◽  
Bo Kyu Kim ◽  
Jaeil Ryu

Abstract BACKGROUND The optimal magnetic resonance angiography (MRA) sequence for assessing the aneurysm occlusion state or in-stent flow after endovascular coiling is not well established. OBJECTIVE To evaluate the diagnostic performance of pointwise encoding time reduction with radial acquisition (PETRA)-MRA in patients who underwent endovascular coiling relative to that of time-of-flight (TOF)-MRA and contrast-enhanced (CE)-MRA. METHODS We evaluated the aneurysm occlusion state using digital subtraction angiography (DSA) and MRA. In patients who underwent stent-assisted coiling, we estimated the visibility of in-stent flow. RESULTS We enrolled 189 patients with assessable TOF, PETRA, and CE-MRAs after coiling. In patients who underwent simple coiling (128 patients), PETRA showed a higher sensitivity in the detection of residual flow than TOF and CE (PETRA, 100%; CE, 83%; TOF, 80%). There were no significant differences in the height of residual flow between DSA (0.68 ± 1.45 mm) and PETRA (0.70 ± 1.50 mm; P = 1.000). In patients who underwent stent-assisted coiling (61 patients), PETRA showed the highest sensitivity (88%) in detecting residual flow (CE, 56%; TOF, 31%). Regarding in-stent flow, PETRA, CE, and TOF showed visual scores of ≥3 with frequencies of 96.7%, 85.2%, and 37.7%, respectively. Relative signal-to-noise ratio of PETRA (0.62 ± 0.18) was significantly higher than that of CE (0.56 ± 0.12) and TOF (0.39 ± 0.12; P < .001 for both). CONCLUSION PETRA-MRA showed excellent diagnostic performance in terms of residual flow detection and in-stent flow assessment. PETRA could be a versatile alternative sequence for following up patients with coiled aneurysm.


2014 ◽  
Vol 20 (6) ◽  
pp. 686-692 ◽  
Author(s):  
Akin Levent ◽  
Ihsan Yuce ◽  
Suat Eren ◽  
Omer Ozyigit ◽  
Mecit Kantarci

This study evaluated contrast-enhanced magnetic resonance angiography (CE-MRA) and three-dimensional time-of-flight magnetic resonance angiography (3D-TOF-MRA) through comparisons with digital subtraction angiography (DSA) for the follow-up of intracranial aneurysms treated with detachable coils. Sixty-seven patients with 79 aneurysms underwent 3D-TOF-MRA, CE-MRA, and catheter angiography one year after coiling. Two independent observers classified recanalization status on images as neck or body remnant or no recanalization. For 3D-TOF-MRA and CE-MRA, the intermodality agreement, interobserver agreement, and correlation with angiography were assessed. Sixty-seven patients with 79 coiled aneurysms agreed to participate in the study. Three aneurysms could not be detected on 3D-TOF-MRA, so they were excluded from this study. Interobserver agreement was very good for 3D-TOF-MRA and CE-MRA (kappa (κ): 0.87, 0.94, respectively). Correlation of TOF-MRA with angiography was good (κ: 0.76). Correlation of CE-MRA with angiography was excellent (κ: 0.91). The sensitivity and specificity of TOF-MRA were 92% and 98%, respectively. The sensitivity and specificity of CE-MRA were 96% and 98%, respectively. After selective embolization of intracranial aneurysms, CE-MRA is useful and comparable to DSA in the assessment of aneurysmal recanalization. Agreement with the gold standard is stronger with CE-MRA than with 3D-TOF-MRA.


2020 ◽  
pp. 028418512095278
Author(s):  
Young Jin Heo ◽  
Hae Woong Jeong ◽  
Donghyun Kim ◽  
Jin Wook Baek ◽  
Ji-yeon Han ◽  
...  

Background Although time-of-flight magnetic resonance angiography (TOF-MRA) is widely used, it has limited usefulness for follow-up after stent-assisted coil embolization. Contrast-enhanced MRA (CE-MRA) and ultrashort echo time MRA have been suggested as alternative methods for visualization after this procedure. Purpose To compare efficacy and usefulness of pointwise encoding time reduction with radial acquisition (PETRA) sequence in subtraction-based MRA (qMRA), TOF-MRA, and CE-MRA during the follow-up after Neuroform Atlas stent-assisted coil embolization for intracranial aneurysms. Material and Methods This retrospective study included 23 patients with 24 aneurysms who underwent Neuroform Atlas stent-assisted coil embolization for intracranial aneurysms. All patients were evaluated with PETRA qMRA, TOF-MRA, and CE-MRA at the same follow-up session. The flow within stents, occlusion status, and presence of pseudo-stenosis were evaluated; inter-observer and intermodality agreements for the three methods were also graded. Results The mean score for flow visualization within the stents was significantly higher for PETRA qMRA and CE-MRA than for TOF-MRA (although no significant difference was found between PETRA qMRA and CE-MRA). Good inter-observer agreement was observed for each modality. PETRA qMRA and CE-MRA were more consistent with digital subtraction angiography (DSA) than TOF-MRA for aneurysm occlusion status. The intermodality agreement was better between PETRA qMRA and DSA, and between CE-MRA and DSA, than between DSA and TOF-MRA. Pseudo-stenosis was most frequently observed in TOF-MRA, followed by CE-MRA and PETRA qMRA. Conclusion PETRA qMRA is useful for evaluating the parent artery patency and occlusion status of aneurysms after Neuroform Atlas stent-assisted coil embolization.


2021 ◽  
pp. 159101992110659
Author(s):  
Young Jin Heo ◽  
Donghyun Kim ◽  
Hae Woong Jeong ◽  
Jin Wook Baek ◽  
Da Som Kim ◽  
...  

Purpose Imaging follow-up after endovascular treatment is important; however, time-of-flight magnetic resonance angiography (TOF-MRA) has limitations associated with magnetic susceptibility and radiofrequency shielding caused by the stent and coils. We evaluated the diagnostic performance of pointwise encoding time reduction with radial acquisition (PETRA)-MRA after endovascular treatment for intracranial aneurysms. Material and methods A total of 186 patients with 211 aneurysms who underwent both pointwise encoding time reduction with radial acquisition- and time-of-flight magnetic resonance angiography in the same imaging session for follow-up after endovascular treatment. We subjectively graded the overall image quality, visualization of treated sites, and occlusion status. Results Although the overall image quality scores of pointwise encoding time reduction with radial acquisition-magnetic resonance angiography were significantly lower than those of time-of-flight magnetic resonance angiography for both observers (4.04 ± 0.81 vs. 4.85 ± 0.35 [observer 1], 4.60 ± 0.69 vs. 4.94 ± 0.24 [observer 2]) (both P < .001), the visibility of treated sites using pointwise encoding time reduction with radial acquisition-magnetic resonance angiography was significantly better than that of time-of-flight magnetic resonance angiography overall (4.27 ± 0.97 vs. 3.42 ± 1.01; P < .001), in the distal internal carotid artery (4.46 ± 0.79 vs. 3.40 ± 1.00; P < .001), and in the middle cerebral artery (4.19 ± 0.93 vs. 3.08 ± 0.53, P = 0.007). Pointwise encoding time reduction with radial acquisition-magnetic resonance angiography showed a higher area under the curve than time-of-flight magnetic resonance angiography for the evaluation of treated aneurysm occlusion, except for posterior circulation aneurysms. Conclusions Pointwise encoding time reduction with radial acquisition-magnetic resonance angiography showed better visualization of treated sites and better diagnostic performance than time-of-flight magnetic resonance angiography for anterior circulation aneurysms. However, Pointwise encoding time reduction with radial acquisition-magnetic resonance angiography showed limitations in the follow-up evaluation of posterior circulation aneurysms.


Author(s):  
Daphne Schönegg ◽  
Raphael Ferrari ◽  
Julian Ebner ◽  
Michael Blumer ◽  
Martin Lanzer ◽  
...  

Abstract Purpose The close topographic relationship between vascular and osseous structures in the condylar and subcondylar region and marked variability in the arterial course has been revealed by both imaging and cadaveric studies. This study aimed to verify the previously published information in a large sample and to determine a safe surgical region. Methods We analyzed the three-dimensional time-of-flight magnetic resonance angiography images of 300 individuals. Results The mean distance between the middle meningeal artery and the apex of the condyle or the most medial point of the condyle was 18.8 mm (range: 11.2–25.9 mm) or 14.5 mm (range: 8.8–22.9 mm) respectively. The course of the maxillary artery relative to the lateral pterygoid muscle was medial in 45.7% of cases and lateral in 54.3%. An asymmetric course was evident in 66 patients (22%). The mean distance between the maxillary artery and condylar process at the deepest point of the mandibular notch was 6.2 mm in sides exhibiting a medial course (range: 3.7–9.8 mm) and 6.6 mm in sides exhibiting a lateral course (range: 3.9–10.4 mm). The distances were significantly influenced by age, gender, and the course of the maxillary artery. Conclusion Our study emphasizes the marked inter- and intra-individual variability of the maxillary and middle meningeal arterial courses. We confirmed the proximity of the arteries to the condylar process. Extensive surgical experience and thorough preparation for each individual case are essential to prevent iatrogenic vascular injury.


2021 ◽  
Vol 84 (2) ◽  
pp. 119-123
Author(s):  
Mami Ishikawa ◽  
Satoshi Terao ◽  
Hiroshi Kagami ◽  
Makoto Inaba ◽  
Heiji Naritaka

<b><i>Background:</i></b> Patients with moyamoya disease often develop cerebral infarction and hemorrhage, but the ischemic and hemorrhagic subtypes are difficult to diagnose prior to disease onset. We aimed to differentiate the ischemic and hemorrhagic subtypes of moyamoya disease by analyzing the intralateral and perilateral ventricular arteries on the original axial magnetic resonance angiography (MRA) images. <b><i>Methods:</i></b> We retrospectively analyzed the intralateral and perilateral ventricular arteries on the original axial time-of-flight (TOF)-MRA images of 18 patients with hemorrhagic moyamoya disease, 25 patients with ischemic moyamoya disease, and 22 control patients with unruptured aneurysms. <b><i>Results:</i></b> There were significantly more intralateral and perilateral ventricular arteries on the original axial MRA images in the patients with hemorrhagic moyamoya disease (6.3 ± 2.7) than in those with ischemic moyamoya disease (0.8 ± 0.9) and those with unruptured aneurysms (0.4 ± 0.8). <b><i>Conclusion:</i></b> The intralateral and perilateral ventricular arteries on the original axial TOF-MRA images might suggest the hemorrhagic type of moyamoya disease prior to onset.


2021 ◽  
Vol 8 ◽  
Author(s):  
Feifei Zhang ◽  
Yuncai Ran ◽  
Ming Zhu ◽  
Xiaowen Lei ◽  
Junxia Niu ◽  
...  

Background and Purpose: 3D pointwise encoding time reduction magnetic resonance angiography (PETRA-MRA) is a promising non-contrast magnetic resonance angiography (MRA) technique for intracranial stenosis assessment but it has not been adequately validated against digital subtraction angiography (DSA) relative to 3D-time-of-flight (3D-TOF) MRA. The aim of this study was to compare PETRA-MRA and 3D-TOF-MRA using DSA as the reference standard for intracranial stenosis assessment before and after angioplasty and stenting in patients with middle cerebral artery (MCA) stenosis.Materials and Methods: Sixty-two patients with MCA stenosis (age 53 ± 12 years, 43 males) underwent MRA and DSA within a week for pre-intervention evaluation and 32 of them had intracranial angioplasty and stenting performed. The MRAs' image quality, flow visualization within the stents, and susceptibility artifact were graded on a 1–4 scale (1 = poor, 4 = excellent) independently by three radiologists. The degree of stenosis was measured by two radiologists independently on DSA and MRAs.Results: There was an excellent inter-observer agreement for stenosis assessment on PETRA-MRA, 3D-TOF-MRA, and DSA (ICCs &gt; 0.90). For pre-intervention evaluation, PETRA-MRA had better image quality than 3D-TOF-MRA (3.87 ± 0.34 vs. 3.38 ± 0.65, P &lt; 0.001), and PETRA-MRA had better agreement with DSA for stenosis measurements compared to 3D-TOF-MRA (r = 0.96 vs. r = 0.85). For post-intervention evaluation, PETRA-MRA had better image quality than 3D-TOF-MRA for in-stent flow visualization and susceptibility artifacts (3.34 ± 0.60 vs. 1.50 ± 0.76, P &lt; 0.001; 3.31 ± 0.64 vs. 1.41 ± 0.61, P &lt; 0.001, respectively), and better agreement with DSA for stenosis measurements than 3D-TOF-MRA (r = 0.90 vs. r = 0.26). 3D-TOF-MRA significantly overestimated the stenosis post-stenting compared to DSA (84.9 ± 19.7 vs. 39.3 ± 13.6%, p &lt; 0.001) while PETRA-MRA didn't (40.6 ± 13.7 vs. 39.3 ± 13.6%, p = 0.18).Conclusions: PETRA-MRA is accurate and reproducible for quantifying MCA stenosis both pre- and post-stenting compared with DSA and performs better than 3D-TOF-MRA.


Sign in / Sign up

Export Citation Format

Share Document