scholarly journals Evaluation of the waste heat utilization from a hot-water-cooled high performance computer via a heat pump

2021 ◽  
Vol 7 ◽  
pp. 70-78
Author(s):  
Frederik Feike ◽  
Johannes Oltmanns ◽  
Frank Dammel ◽  
Peter Stephan
2020 ◽  
Vol 8 (5) ◽  
pp. 1793-1810
Author(s):  
Johannes Oltmanns ◽  
David Sauerwein ◽  
Frank Dammel ◽  
Peter Stephan ◽  
Christoph Kuhn

2007 ◽  
Vol 11 (3) ◽  
pp. 165-172 ◽  
Author(s):  
Slavomir Smolen ◽  
Marzena Budnik-Rodz

The main aim of the following presentation is the comparison and evaluation of the conditions for waste heat utilization in Germany and in Poland. This paper presents synthetically the results of economic analysis of the different technical variants. The employment of heat pumps and other heat transformers, respectively, can reduce the energy consumption, but using of those technical possibilities depends mainly on the economic aspects. The main parameters of the financial calculations were the energy and equipment costs but beyond it a number of other factors were also considered and compared, for example calculation interests, profit tax level and similar. Four different technical alternatives were analyzed, it is using of absorption heat pump, compression heat pump, heat transformer (absorption), and a special combined system with gas motor to drive of heat pump compressor. The capital value as main result of the investigations is in Poland generally lower because of relatively high investment cost and lower energy prices compared to the situation in Germany and West Europe. The basis for the presented comparative analysis was an industrial project in Germany which effected in development of concepts for waste heat using. .


1989 ◽  
Vol 19 (3) ◽  
pp. 211-229 ◽  
Author(s):  
Robert N. Amundsen ◽  
John D. Keenan

1989 ◽  
Vol 19 (2) ◽  
pp. 95-114 ◽  
Author(s):  
John D. Keenan ◽  
Robert N. Amundsen

Energies ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 954 ◽  
Author(s):  
Hanne Kauko ◽  
Daniel Rohde ◽  
Armin Hafner

District heating enables an economical use of energy sources that would otherwise be wasted to cover the heating demands of buildings in urban areas. For efficient utilization of local waste heat and renewable heat sources, low distribution temperatures are of crucial importance. This study evaluates a local heating network being planned for a new building area in Trondheim, Norway, with waste heat available from a nearby ice skating rink. Two alternative supply temperature levels have been evaluated with dynamic simulations: low temperature (40 °C), with direct utilization of waste heat and decentralized domestic hot water (DHW) production using heat pumps; and medium temperature (70 °C), applying a centralized heat pump to lift the temperature of the waste heat. The local network will be connected to the primary district heating network to cover the remaining heat demand. The simulation results show that with a medium temperature supply, the peak power demand is up to three times higher than with a low temperature supply. This results from the fact that the centralized heat pump lifts the temperature for the entire network, including space and DHW heating demands. With a low temperature supply, heat pumps are applied only for DHW production, which enables a low and even electricity demand. On the other hand, with a low temperature supply, the district heating demand is high in the wintertime, in particular if the waste heat temperature is low. The choice of a suitable supply temperature level for a local heating network is hence strongly dependent on the temperature of the available waste heat, but also on the costs and emissions related to the production of district heating and electricity in the different seasons.


Proceedings ◽  
2020 ◽  
Vol 65 (1) ◽  
pp. 25
Author(s):  
Antonio Garrido Marijuan ◽  
Roberto Garay ◽  
Mikel Lumbreras ◽  
Víctor Sánchez ◽  
Olga Macias ◽  
...  

District heating networks deliver around 13% of the heating energy in the EU, being considered as a key element of the progressive decarbonization of Europe. The H2020 REnewable Low TEmperature District project (RELaTED) seeks to contribute to the energy decarbonization of these infrastructures through the development and demonstration of the following concepts: reduction in network temperature down to 50 °C, integration of renewable energies and waste heat sources with a novel substation concept, and improvement on building-integrated solar thermal systems. The coupling of renewable thermal sources with ultra-low temperature district heating (DH) allows for a bidirectional energy flow, using the DH as both thermal storage in periods of production surplus and a back-up heating source during consumption peaks. The ultra-low temperature enables the integration of a wide range of energy sources such as waste heat from industry. Furthermore, RELaTED also develops concepts concerning district heating-connected reversible heat pump systems that allow to reach adequate thermal levels for domestic hot water as well as the use of the network for district cooling with high performance. These developments will be demonstrated in four locations: Estonia, Serbia, Denmark, and Spain.