Misidentification of Brucella melitensis as Octrobactrum deajoenense with MALDI-TOF MS: A report of three cases

Author(s):  
Neşe Inal ◽  
Gülşen Hazırolan
2021 ◽  
Vol 12 ◽  
Author(s):  
David Kornspan ◽  
Holger Brendebach ◽  
Dirk Hofreuter ◽  
Shubham Mathur ◽  
Shlomo Eduardo Blum ◽  
...  

Brucella melitensis Rev.1 is a live attenuated vaccine strain that is widely used to control brucellosis in small ruminants. For successful surveillance and control programs, rapid identification and characterization of Brucella isolates and reliable differentiation of vaccinated and naturally infected animals are essential prerequisites. Although MALDI-TOF MS is increasingly applied in clinical microbiology laboratories for the diagnosis of brucellosis, species or even strain differentiation by this method remains a challenge. To detect biomarkers, which enable to distinguish the B. melitensis Rev.1 vaccine strain from B. melitensis field isolates, we initially searched for unique marker proteins by in silico comparison of the B. melitensis Rev.1 and 16M proteomes. We found 113 protein sequences of B. melitensis 16M that revealed a homologous sequence in the B. melitensis Rev.1 annotation and 17 of these sequences yielded potential biomarker pairs. MALDI-TOF MS spectra of 18 B. melitensis Rev.1 vaccine and 183 Israeli B. melitensis field isolates were subsequently analyzed to validate the identified marker candidates. This approach detected two genus-wide unique biomarkers with properties most similar to the ribosomal proteins L24 and S12. These two proteins clearly discriminated B. melitensis Rev.1 from the closely related B. melitensis 16M and the Israeli B. melitensis field isolates. In addition, we verified their discriminatory power using a set of B. melitensis strains from various origins and of different MLVA types. Based on our results, we propose MALDI-TOF MS profiling as a rapid, cost-effective alternative to the traditional, time-consuming approach to differentiate certain B. melitensis isolates on strain level.


Author(s):  
D. V. Ulshina ◽  
D. A. Kovalev ◽  
D. G. Ponomarenko ◽  
D. V. Rusanova ◽  
N. M. Shvetsova ◽  
...  

Aim.Study the possibility to apply time-of-flight mass-spectrometry for detection of causative agent of brucellosis in blood. Materials and methods. Brucella strains: 5 Brucella melitensis and 21 Brucella abortus. Protein profiling in linear mode on MALD1-TOF mass-spectrometer Microflex «Bruker Daltonics». Results. Technique for disinfection and preparation of blood samples was modified and optimized for MALDI-TOF MS analysis. 120 representative protein profiles of sera extract were obtained that contain brucellosis causative agent. A resulting peak-list (super-spectrum) of the studied protein fraction of blood extract of a conditionally healthy human within the studied group was formed and analyzed. Conclusion. A scheme of brucella detection in blood samples by MALDI-TOF MS is proposed, based on detection of a complex of 15 genus-specific fragments. Signals on mass-spectra of extracts of leukocyte fraction of blood, artificially contaminated with brucellosis causative agents are characterized.


2020 ◽  
Vol 33 (3) ◽  
pp. 223-224
Author(s):  
Tatiana Khaliulina Ushakova ◽  
Ana Isabel Perera Leringía ◽  
Juan Sahagún Pareja ◽  
Raquel Dolz Aspas ◽  
Marta Puyal Barcelona ◽  
...  

2007 ◽  
Vol 177 (4S) ◽  
pp. 297-297
Author(s):  
Kristina Schwamborn ◽  
Rene Krieg ◽  
Ruth Knüchel-Clarke ◽  
Joachim Grosse ◽  
Gerhard Jakse

Planta Medica ◽  
2016 ◽  
Vol 81 (S 01) ◽  
pp. S1-S381
Author(s):  
L Fougère ◽  
D Da Silva ◽  
E Destandau ◽  
C Elfakir
Keyword(s):  

2017 ◽  
Author(s):  
M Erhard ◽  
M Metzner ◽  
D Köhler-Repp ◽  
B Köhler ◽  
R Storandt
Keyword(s):  

2019 ◽  
Author(s):  
M Hooshyari ◽  
H Rezadoost ◽  
P Ghezellou ◽  
A Ghassempour

Sign in / Sign up

Export Citation Format

Share Document