A novel poloxamers/hyaluronic acid in situ forming hydrogel for drug delivery: Rheological, mucoadhesive and in vitro release properties

2008 ◽  
Vol 70 (1) ◽  
pp. 199-206 ◽  
Author(s):  
L MAYOL ◽  
F QUAGLIA ◽  
A BORZACCHIELLO ◽  
L AMBROSIO ◽  
M ROTONDA
2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Elham Khodaverdi ◽  
Fatemeh Kheirandish ◽  
Farnaz Sadat Mirzazadeh Tekie ◽  
Bibi Zahra Khashyarmanesh ◽  
Farzin Hadizadeh ◽  
...  

In situ forming delivery systems composed of block copolymers are attracting substantial attention due to their ease of use, biocompatibility, and biodegradability. In this study, the thermoresponsive triblock copolymer PLGA-PEG-PLGA was studied as a dexamethasone delivery system. Dexamethasone, a synthetic glucocorticoid, is used clinically to improve inflammation, pain, and the hyperemesis of chemotherapy, and it is applied experimentally as a differentiation factor in tissue engineering. PLGA-PEG-PLGA was synthesised under microwave irradiation for 5 min. The obtained copolymer was characterised to determine its structure and phase transition temperature. An in vitro release study was conducted for various copolymer structures and drug concentrations. The yield of the reaction and HNMR analysis confirmed the appropriateness of the microwave-assisted method for PLGA-PEG-PLGA synthesis. Phase transition temperature was affected by the drug molecule as well as by the copolymer concentration and structure. An in vitro release study demonstrated that release occurs mainly by diffusion and does not depend on the copolymer structure or dexamethasone concentration.


2021 ◽  
Vol 14 (1) ◽  
pp. 66
Author(s):  
Mohamed Haider ◽  
Ibrahim Elsayed ◽  
Iman S. Ahmed ◽  
Ahmed R. Fares

In this work, sucrose acetate isobutyrate (SAIB) and polylactic co-glycolic acid (PLGA) were used alone or in combination as a matrix-former (MF) to prepare long-acting injectable rivastigmine (RV) in situ-forming microparticles (ISM). RV-ISM were prepared by the emulsification of an internal phase, containing the drug and the matrix former(s), into an external oily phase containing a stabilizer. The statistical design, Central Composite Design (CCD), was adopted as a quality by design (QbD) approach to optimize the formulation of RV-ISM systems. The fabricated RV-ISM systems was designed to minimize the initial burst drug release and maximize the sustainment of RV release from the ISM and ease of injection. The influence of critical formulation variables such as the matrix-former to drug (MF/D) ratio and SAIB to PLGA (S/P) ratio in the internal phase with respect to critical quality attributes (CQAs), such as the percentage drug release within the first day (Q1), the time required for 50% drug release (T50%) and the rate of injection, were studied using the CCD. The optimal RV-ISM system with the highest desirability value (0.74) was predicted to have an MF/D ratio of 11.7:1 (w/w) and an S/P ratio of 1.64:1 (w/w). The optimal RV-ISM system was assessed for its release profile, injectability, rheological properties, morphology, effect on cell viability, tolerance to γ-sterilization and in vivo performance in male albino rabbits. In vitro release studies revealed that the optimal RV-ISM system released 100% of its drug content throughout a release period of 30 days with only 15.5% drug release within the first day (Q1) and T50% of 13.09 days. Moreover, the optimal system showed a high injection rate of 1.012 mL/min, pseudoplastic flow, uniform spherical globules with homogenous particle size, minimal cytotoxicity and high tolerability to γ-sterilization. In vivo pharmacokinetic (PK) studies revealed that the rate of absorption of RV from the optimal RV-ISM system was controlled compared to a drug solution following either intramuscular (IM) or subcutaneous (SC) injection. Furthermore, the optimal RV-ISM was found to follow flip-flop PK with poor correlation between in vitro release and in vivo findings. These findings suggest that the optimal RV-ISM is a promising tool to achieve a sustained release therapy for RV; however, further investigation is still required to optimize the in vivo performance of RV-ISM.


2020 ◽  
Vol 17 (2) ◽  
pp. 174-183
Author(s):  
Elham Khodaverdi ◽  
Khadijeh Delroba ◽  
Fatemeh Mohammadpour ◽  
Bahman Khameneh ◽  
Sayyed A. Sajadi Tabassi ◽  
...  

Objective: An injectable long acting In-Situ Forming Gel (ISFG) of human Growth Hormone (hGH) was prepared by using triblock PCL-­‐PEG-­‐PCL (Mw 1500-1500-1500). Ring-Opening Polymerization (ROP) of triblock using microwave was applied. Methods: The BCA protein assay Kit was used to determine the concentration of hGH in the in-vitro release medium. Finally, Sodium Dodecyl Sulfate-Polyacrylamide Gel Electrophoresis (SDS-PAGE) tests and Circular Dichroism (CD) spectrum were done to approve the stability of released hGH. The result of ROP demonstrated that the proportion of PCL to PEG accorded with the initial molar ratio of the monomers. The cross-section of the Surface Electron Microscopy (SEM) indicated the porous framework of the hydrogel could load the drug into its tridimensional matrixes structure. There is the low initial burst release of hGH from the supramolecular hydrogel. Results: The maximum in-vitro release of hGH was 71.2 % ± 1.5 that were due to hGH degrading after this time (21 days). The CD spectrum and SDS-PAGE results confirmed the stability of hGH during invitro release evaluation. Conclusion: The results suggest that the sustained-release formulation using PCL-PEG-PCL can be applied to control the release of hGH.


2007 ◽  
Vol 25 (6) ◽  
pp. 1347-1354 ◽  
Author(s):  
Heiko Kranz ◽  
Erol Yilmaz ◽  
Gayle A. Brazeau ◽  
Roland Bodmeier

Sign in / Sign up

Export Citation Format

Share Document