scholarly journals Performances of low temperature radiant heating systems

2013 ◽  
Vol 61 ◽  
pp. 233-238 ◽  
Author(s):  
Milorad Bojić ◽  
Dragan Cvetković ◽  
Vesna Marjanović ◽  
Mirko Blagojević ◽  
Zorica Djordjević
Energies ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 2932 ◽  
Author(s):  
M. Safizadeh ◽  
Marcel Schweiker ◽  
Andreas Wagner

Low-temperature radiant heating systems can be considered as suitable candidates for the refurbishment of old heating systems. These systems are proven to save energy, however, their drawback is their impact on the creation of radiant temperature asymmetry and local thermal discomfort, especially in old buildings where the temperatures of surfaces (for example external walls with a low level of insulation and large windows) are low. This study aims to evaluate the potential application of low-temperature radiant ceiling heating systems (28–38 °C) in old and energy-renovated buildings, based on subjective experiments and thermal comfort criteria such as thermal sensation, comfort, satisfaction, and sensation asymmetry votes. Later, in the Discussion section, the guideline for the radiant temperature asymmetry for the warm ceiling presented in ASHRAE Standard-55 is corrected for relatively low air temperatures and different surface temperatures corresponding to “about neutral” conditions for winter clothing. Findings of this research show that the radiant ceiling heating system operating at low temperatures (33–38 °C) can provide fairly neutral thermal sensation and satisfactory comfort at the majority of body-parts, if the building envelope satisfies advanced building energy-efficiency regulations. Additionally, the experimental analyses imply that limitation of 5% suggested by ASHRAE-55 for the percentage of dissatisfied occupants feeling uncomfortable due to overhead radiation can be elevated to 10%.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3218
Author(s):  
Pedro Durán ◽  
Herena Torio ◽  
Patrik Schönfeldt ◽  
Peter Klement ◽  
Benedikt Hanke ◽  
...  

There are 1454 district heating systems in Germany. Most of them are fossil based and with high temperature levels, which is neither efficient nor sustainable and needs to be changed for reaching the 2050 climate goals. In this paper, we present a case study for transforming a high to low temperature district heating system which is more suitable for renewable energy supply. With the Carnot Toolbox, a dynamic model of a potential district heating system is simulated and then transformed to a low temperature supply. A sensitivity analysis is carried out to see the system performance in case space constrains restrict the transformation. Finally, an economic comparison is performed. Results show that it is technically possible to perform the transformation until a very low temperature system. The use of decentralized renewable sources, decentralized heat storage tanks and the placement of a heat pump on each building are the key points to achieve the transformation. Regarding the sensitivity analysis, the transformation is worth doing until the seasonal storage and solar collector field sizes are reduced to 60% and 80% of their values in the reference case, respectively. The economic analysis shows, however, that it is hard for highly efficient low temperature renewable based heat networks to compete with district heating systems based on a centralized fossile CHP solution. Thus, though the presented transformation is technically possible, there is a strong need to change existing economic schemes and policies for fostering a stronger promotion of renewable energy policies in the heat sector.


2018 ◽  
Vol 8 (10) ◽  
pp. 1973 ◽  
Author(s):  
Adnan Ploskić ◽  
Qian Wang ◽  
Sasan Sadrizadeh

The aim of this study was to map the parameters that have the greatest impact on the environmental impact of heating systems usually used in Nordic single-family dwellings. The study focused on mapping the technical requirements for efficient operation of heating systems in a broader context. The results suggest that the ability of a heating system to be operated with a low-temperature water supply depends to a large extent on the heating demand of a building. It was shown that an increase in the water flow rate in hydronic circuits would significantly increase the thermal efficiency from analyzed heating systems. This increase would not increase the pumping power need, nor would it create noise problems in distribution network if the distribution pipes and thermostatic valves were properly selected. However, this increase in water flow rate improved the efficiency of considered closed-loop heat pump. It was further shown that the efficiency of the heat pump could be additionally improved by halving the energy needs for the domestic hot-water and circulators. The main conclusion from this study is that exergy usage, CO2 emission and thereby environmental impact are significantly lower for heating systems that are operated with small temperature drops.


Entropy ◽  
2019 ◽  
Vol 21 (4) ◽  
pp. 388
Author(s):  
Poredoš ◽  
Kitanovski ◽  
Poredoš

This paper presents an exergy-efficiency analysis of low-temperature district heating systems (DHSs) with different sanitary hot-water (SHW) boosters. The required temperature of the sanitary hot water (SHW) was set to 50 °C. The main objective of this study was to compare the exergy efficiencies of a DHS without a booster to DHSs with three different types of boosters, i.e., electric-, gas-boiler- and heat-pump-based, during the winter and summer seasons. To achieve this, we developed a generalized model for the calculation of the exergy efficiency of a DHS with or without the booster. The results show that during the winter season, for a very low relative share of SHW production, the DHS without the booster exhibits favorable exergy efficiencies compared to the DHSs with boosters. By increasing this share, an intersection point above 45 °C for the supply temperatures, at which the higher exergy efficiency of a DHS with a booster prevails, can be identified. In the summer season the results show that a DHS without a booster at a supply temperature above 70 °C achieves lower exergy efficiencies compared to DHSs with boosters at supply temperatures above 40 °C. The results also show that ultra-low supply and return temperatures should be avoided for the DHSs with boosters, due to higher rates of entropy generation.