Parametric design and off-design analysis of organic Rankine cycle (ORC) system

2016 ◽  
Vol 112 ◽  
pp. 157-165 ◽  
Author(s):  
Jian Song ◽  
Chun-wei Gu ◽  
Xiaodong Ren
2014 ◽  
Vol 672-674 ◽  
pp. 741-745
Author(s):  
Shuang Bian ◽  
Teng Wu ◽  
Jin Fu Yang

Organic Rankine Cycle (ORC) is widely used in the field of low temperature waste heat recovery, including solar, biomass and geothermal energy, among others. Based on the thermodynamic model of ORC system built up in Matlab, this study employ Genetic Algorithm (GA) on ORC system for parametric optimization and select a ratio of heat transfer area to total net power output as the performance evaluation criterion to predict the economy of system. R11, R113, R123 and isopentane are choosed as the working medium. The results show that the ORC system with isopentane has the minimum objective function value of 0.429m2/kw. The corresponding condensing temperature and degree of supercooling are generally located at lower boundary over their parametric design ranges, and the corresponding pinch point temperature difference are located at upper boundary. For different working fluids, there exist an optimum evaporating temperature and degree of superheat.


2020 ◽  
Vol 92 (1) ◽  
pp. 10906
Author(s):  
Jeroen Schoenmaker ◽  
Pâmella Gonçalves Martins ◽  
Guilherme Corsi Miranda da Silva ◽  
Julio Carlos Teixeira

Organic Rankine Cycle (ORC) systems are increasingly gaining relevance in the renewable and sustainable energy scenario. Recently our research group published a manuscript identifying a new type of thermodynamic cycle entitled Buoyancy Organic Rankine Cycle (BORC) [J. Schoenmaker, J.F.Q. Rey, K.R. Pirota, Renew. Energy 36, 999 (2011)]. In this work we present two main contributions. First, we propose a refined thermodynamic model for BORC systems accounting for the specific heat of the working fluid. Considering the refined model, the efficiencies for Pentane and Dichloromethane at temperatures up to 100 °C were estimated to be 17.2%. Second, we show a proof of concept BORC system using a 3 m tall, 0.062 m diameter polycarbonate tube as a column-fluid reservoir. We used water as a column fluid. The thermal stability and uniformity throughout the tube has been carefully simulated and verified experimentally. After the thermal parameters of the water column have been fully characterized, we developed a test body to allow an adequate assessment of the BORC-system's efficiency. We obtained 0.84% efficiency for 43.8 °C working temperature. This corresponds to 35% of the Carnot efficiency calculated for the same temperature difference. Limitations of the model and the apparatus are put into perspective, pointing directions for further developments of BORC systems.


2017 ◽  
Author(s):  
Weicong Xu ◽  
Li Zhao ◽  
Shuai Deng ◽  
Jianyuan Zhang ◽  
Wen Su

Author(s):  
Flávio Pacelli Ziviani de Oliveira ◽  
Henrique Neiva Guimarães ◽  
Breno Gusmão Barbosa

Sign in / Sign up

Export Citation Format

Share Document