scholarly journals Behavior of CFRP partially wrapped square seawater sea-sand concrete columns under axial compression

2020 ◽  
Vol 222 ◽  
pp. 111119
Author(s):  
Junlong Yang ◽  
Shiwei Lu ◽  
Jizhong Wang ◽  
Ziru Wang
2017 ◽  
Vol 27 (9) ◽  
pp. 1416-1447 ◽  
Author(s):  
Liu Jin ◽  
Shuai Zhang ◽  
Dong Li ◽  
Haibin Xu ◽  
Xiuli Du ◽  
...  

The results of an experimental program on eight short reinforced concrete columns having different structural sizes and axial compression ratios subjected to monotonic/cyclic lateral loading were reported. A 3D mesoscopic simulation method for the analysis of mechanical properties of reinforced concrete members was established, and then it was utilized as an important supplement and extension of the traditional experimental method. Lots of numerical trials, based on the restricted experimental results and the proposed 3D mesoscopic simulation method, were carried out to sufficiently evaluate the seismic performances of short reinforced concrete columns with different structural sizes and axial compression ratios. The test results indicate that (1) the failure pattern of reinforced concrete columns can be significantly affected by the shear-span ratio; (2) increasing the axial compression ratio could improve the load capacity of the reinforced concrete column, but the deformation capacity would be restricted and the failure mode would be more brittle, consequently the energy dissipation capacity could be deteriorated; and (3) the load capacity, the displacement ductility, and the energy dissipation capacity of the short reinforced concrete columns all exhibit clear size effect, namely, the size effect could significantly affect the seismic behavior of reinforced concrete columns.


2017 ◽  
Vol 210 ◽  
pp. 203-210
Author(s):  
Zhi-Jian Zhang ◽  
Hai-Yan Zhang ◽  
Jun-Hong Zheng ◽  
Kai-Hang Lin ◽  
Yi Su

2011 ◽  
Vol 368-373 ◽  
pp. 248-252
Author(s):  
Bao Sheng Yang ◽  
Yun Yun Li

The influence on columns behaviors of slenderness ratio are analyzed, and the influence on columns’ anti-seismic behavior of axial compression ratio, stirrup ratio and steel form are analyzed through the test on bearing capacity and level load of low cycle reverse of steel reinforced high-strength concrete columns. The bearing capacity of the long columns reduces along with the slenderness ratio increasing and augments along with concrete strength increasing. Probability of suddenly destruct increases along with the column slenderness ratio augmenting through the test. In addition, anti-seismic behavior of columns are effected not only axial compression ratio, but also steel form. Axial compression coefficien of the steel reinforced high-strength concrete columns with different steel form may be adjusted, however, the influence of stirrup ratio is very little on anti-seismic behavior of columns.


Sign in / Sign up

Export Citation Format

Share Document