Simplified Modelling of Transient Ground Potential Rise of GIS in Ultra-high-voltage Substations with Hybrid Reactive Power Compensation

2021 ◽  
Vol 199 ◽  
pp. 107441
Author(s):  
Hongshun Liu ◽  
Ziyue Zhang ◽  
Taiyu Chen ◽  
Jingjing Yang ◽  
Qingquan Li ◽  
...  
Energies ◽  
2018 ◽  
Vol 11 (1) ◽  
pp. 100 ◽  
Author(s):  
Hongshun Liu ◽  
Zhen Wang ◽  
Jingjing Yang ◽  
Bin Li ◽  
Ang Ren

IEEE Access ◽  
2018 ◽  
Vol 6 ◽  
pp. 38115-38123 ◽  
Author(s):  
Hongshun Liu ◽  
Jingjing Yang ◽  
Liang Ji ◽  
Zhen Wang ◽  
Zhenning Huang ◽  
...  

2012 ◽  
Vol 433-440 ◽  
pp. 2406-2410
Author(s):  
Dong Mei Sun ◽  
Jun Wen

In order to balance reactive power, reduce line losses, prevent excessive power frequency and switching over-voltage and adjust and control the line voltage etc. The long-distance and high voltage transmission lines are needed reactive power compensation. High voltage overhead transmission lines and high voltage submarine cable (including mixed-submarine) transmission lines are different, for example, the capacitance in the submarine cable lines is larger than in the conventional overhead lines. Therefore, the reactive power compensation on the EHV transmission lines which contains submarine cable lines is focus on the compensation of submarine cable lines. The reactive power compensation in 500 kV AC submarine cable interconnection project for Hainan power grid and Guangdong power grid[1], which is the first 500 kV long-distance and high-capacity sea trails interconnection project in China and which is just completed soon, is researched by Electro-Magnetic Transient Program——PSCAD/EMTDC (Power System Computer Aided Design/ Electro Magnetic Transient in DC System in this paper). The simulation results verifies that the role of shunt reactor which could absorb charging power and suppress the power frequency overvoltage for the long-distance and high-capacity hybrid submarine cable lines. The conclusions can offer references to suppress power frequency overvoltage and the reactive power compensation in extra high voltage transmission lines which is the mixed mode of overhead transmission lines and submarine cables.


2013 ◽  
Vol 380-384 ◽  
pp. 2982-2985
Author(s):  
Hong Da Dong

There are many problems for traditional reactive power compensation devices to be applied in the grid, such as discontinuous adjustment, small capacity, complex control and harmonics. This paper aims to study a high temperature superconducting magnetically controlled saturable reactor (HTS MCSR), which has a wide range of stepless adjustment. It has a good application prospect in large scale reactive power compensation devices. Based on research of theory and core structure, a shaped-cylinder core is proposed. By means of calculation of saturable reactor and analysis of algebraic and magnetic circuit model, design of 220V HTS MCSR is finished. Results of normal conductive reactor prototype and simulations verify that the range of inductance adjustment is very wide. Furthermore, conceptual design of 35kV HTS MCSR confirms its reactive power capacity is so large, therefore, it is suitable for high voltage power system.


2012 ◽  
Vol 468-471 ◽  
pp. 2912-2915 ◽  
Author(s):  
Li Wang ◽  
Yan Qing Pang ◽  
Zhi Ming Song ◽  
Tang Sheng Xun ◽  
Hong Yu Gao ◽  
...  

This article introduces the trigger circuit of series SCRs valve and a new trigger circuit is designed for series SCRs valve of TSC. The trigger circuit is driven by voltage source and a high voltage cable is used for insulation of the pulse transformer. The trigger circuit has simple structure and a steep front of gate-current. This unit is used in 10 kV thyristor switched capacitor (TSC) reactive power compensation device, and the results verify its feasibility.


2021 ◽  
Vol 13 (4) ◽  
pp. 267-272
Author(s):  
M. M. Sultanov ◽  
A. V. Strizhichenko ◽  
I. A. Boldyrev ◽  
O. I. Zhelyaskova ◽  
E. A. Voloshin ◽  
...  

Reactive power in the power system negatively affects the operating mode of the electric network, additionally loading high-voltage lines and transformers, which leads to an increase in power losses, as well as to an increase in voltage drops. The influence of active and reactive power components of voltage in the network nodes is different and is overwhelmingly determined by the ratio of active and reactive components of the resistance elements of the electric system. In high-voltage networks, the reactive component of the resistance significantly exceeds the active component, and therefore the flow of reactive current through the network leads to a greater voltage drop than the flow of the active component of the current. The transfer of reactive power can lead to exceeding the normalized voltage range in the load nodes. To reduce power losses and voltage drop in the elements of the electric network, synchronous compensators (SC), static capacitor banks (SCB), static thyristor compensators (STC), controlled shunt reactors (CSR) can be used. The cost of production and transmission of active and reactive power are different, and when choosing the power of reactive power compensation means, it is necessary to take into account the costs and compare them with the resulting effect, which differs for large and small values of reactive power when this is reduced by the same amount. To assess the feasibility of application of compensatory devices, and to choose their type and locations of installation, relevant calculations are required. An empirical criterion is proposed for preliminary assessment of the technical feasibility of reactive power compensation. It enables to identify the network sections and nodes, which require reactive power compensation and should be considered in greater detail.


2014 ◽  
Vol 602-605 ◽  
pp. 2828-2831 ◽  
Author(s):  
Yi Fei Wang ◽  
You Xin Yuan ◽  
Jing Chen ◽  
Qi Jian Cheng

According to the low power factor and low running efficiency, a dynamic reactive power compensation method of the super high-power and high-voltage motor is proposed in this paper. The following works have been done in the study: topology of the dynamic reactive power compensation device; principle of the dynamic reactive power compensation method; control system of the dynamic reactive power compensation device; implementation of the dynamic reactive power compensation method. The amount of reactive power compensation can be adjusted smoothly and dynamically in the process of the super high-power and high-voltage motor soft-starting. The research of this paper has laid a theoretical foundation for this compensator in industrial applications. The novel design is characterized by flexible parameter setting, excellent soft starting performance of the super high-power and high-voltage motor and bright prospect in application.


Sign in / Sign up

Export Citation Format

Share Document