Evaluation of the removal performance in long-term operation of bioaugmented subsurface wastewater infiltration systems under a high hydraulic loading rate

Author(s):  
Shengnan Qin ◽  
Fei Huang ◽  
Binhui Jiang ◽  
Liping Jia
2009 ◽  
Vol 44 (2) ◽  
pp. 111-121 ◽  
Author(s):  
Jason C. Vanderzwaag ◽  
James W. Atwater ◽  
Karen H. Bartlett ◽  
Derek Baker

Abstract An evaluation was conducted in 2007 on biosand filters that were installed in Posoltega, Nicaragua in 1999 and 2004.The objectives were to characterize the condition and use of filters eight and three years after installation, determine filter performance of those filters still in use, and identify determinants of successful long-term use and performance. Methods consisted of household identification, user questionnaires, and water quality testing. Of the 234 filters installed, only 24 were found to still be in use. Average log reductions were 1.73 (98%) for total coliforms, 1.36 (96%) for Escherichia Coli, and 0.91 (88%) for turbidity. Statistically significant effects were detected for the magnitude of the contamination of source water, the peak hydraulic loading rate, and the standing depth of water over the filter media. Questionnaire results indicated user training on filter maintenance could improve the peak hydraulic loading rate and hence filter performance. The low rate of sustained use (10%) is an indication of failed implementation, and is attributable to structural failure, particularly cracking of the concrete filters from 2004. Nonetheless, this evaluation demonstrated the biosand filter technology to be robust since those filters still in use were performing as expected three and eight years postimplementation.


Jurnal BiBieT ◽  
2017 ◽  
Vol 2 (2) ◽  
pp. 49
Author(s):  
Welly Herman ◽  
Darmawan Darmawan ◽  
Gusnidar Gusnidar

<p><em>The research aimed to make Volcanic soil of Multiple Soil Layering (MSL) with different Hydraulic Loading Rate (HLR) on the purification of polluted irrigation water and to determine the appropriate HLR against purification of polluted irrigation water. The research used an MSL system of the same Soil Mixture Block (SMB) size from a study done by </em><em>(Chen et al., 2007)</em><em> arranged in an Acrylic box measuring 50 cm x 10 cm x 60 cm (PxLxT). Making SMB is done by mixing volcanic soil, sawdust, iron, charcoal that has been mashed by 50 mesh sieve, with a combination of 7: 1: 1: 1. The MSL system is supplied with irrigation water taken from the Gunuang Nago irrigation and Pasar Baru area, Cupak Tangah village, Pauh IX sub-district, Padang continuously with different HLR of 250 L/m<sup>2</sup>/day,     500 L/m<sup>2</sup>/ day and 1000 L/m<sup>2</sup>/day. From the result of this research, it is found that MSL system can decrease pollutant content in polluted irrigation water until the concentration below the water quality standard based on PP. 82 of 2001 and MSL system with HLR 250 L/m<sup>2</sup>/day have high ability in purifying BOD and COD and HLR 1000 L/m<sup>2</sup>/day has a high ability in purifying NH<sub>4</sub><sup>+</sup>, NO<sub>2</sub><sup>-</sup> and NO<sub>3</sub><sup>-</sup> on polluted irrigation water.</em></p><p class="jbd-alamat"> </p><p class="jbd-alamat">Tujuan penelitian ini adalah untuk menentukan pengaruh tanah vulkanik dalam sistem <em>Multiple Soil Layering</em> (MSL) dengan <em>Hydraulic Loading Rate</em> (HLR) yang berbeda terhadap pemurnian air irigasi terpolusi. Penelitian  menggunakan sistem MSL dengan ukuran <em>Soil Mixture Block</em> (SMB) yang sama dari penelitian yang telah dilakukan (Chen, Sato, Wakatsuki, &amp; Masunaga, 2007)yang disusun di dalam kotak Acrylic berukuran 50 cm x 10 cm x 60 cm (PxLxT).  <em>Soil Mixture Block</em> terdiri dari tanah vulkanik, serbuk gergaji, besi, arang yang telah dihaluskan oleh ayakan 50 mesh, dengan perbandingan kombinasi 7:1:1:1.  Sistem MSL dialirkan air irigasi yang diambil dari irigasi Gunuang Nago dan Kawasan Pasar Baru, Kelurahan Cupak Tangah, Kecamatan Pauh IX, Padang secara terus menerus dengan HLR yang berbeda yaitu 250 L/m<sup>2</sup>/hari,  500 L/m<sup>2</sup>/hari dan 1000 L/m<sup>2</sup>/hari. Dari hasil penelitian diperoleh bahwa sistem MSL mampu menurunkan kandungan zat pencemar pada air irigasi terpolusi  mencapai kosentrasi di bawah baku mutu air berdasarkan PP No. 82 tahun 2001 dengan HLR 250 L/m<sup>2</sup>/hari mempunyai kemampuan yang tinggi dalam memurnikan kadar pencemar BOD dan COD sedangkan HLR 1000 L/m2/hari mempunyai kemampuan yang tinggi dalam memurnikan kadar pencemar NH<sub>4</sub><sup>+</sup>, NO<sub>2</sub><sup>-</sup> dan NO<sub>3</sub><sup>-</sup> pada air irigasi terpolusi.</p>


2010 ◽  
Vol 61 (2) ◽  
pp. 415-420 ◽  
Author(s):  
Sanjib Moulick ◽  
Naresh V. Tambada ◽  
Basant K. Singh ◽  
B. C. Mal

Aeration experiments, maintaining nappe flow conditions, were carried out on a rectangular stepped cascade of total height 3.0 m to determine the total number of steps, slope of the entire cascade and hydraulic loading rate at which maximum overall aeration efficiency occurs, keeping the surface area of individual steps constant. Based on dimensional analysis, the overall aeration efficiency at standard conditions (E20) was expressed as a function of square of total number of steps (N2) and dimensionless discharge (dc/h), where dc and h represent critical depth in a rectangular prismatic channel and individual step height respectively. An empirical equation with E20 as the response and N2 and dc/h as the independent parameters was developed based on the experimental results subject to 36 ≤ N2 ≤ 196 and 0.009 ≤ dc/h ≤ 0.144. The experimental results showed that the overall aeration efficiency (E20) for a particular step height of stepped cascade increases with increase in dc/h up to a certain value and then decreases. This may be due to at higher dc/h, i.e., at higher hydraulic loading rate, the flow approaches the transition zone and thereby aeration efficiency decreases. E20 was also found to increase with number of steps at any hydraulic loading rate, because of the increased surface area of fall. The optimum number of steps, slope of the entire stepped cascade and hydraulic loading rate were found to be 14, 0.351 and 0.009 m2/s respectively producing the maximum value of overall aeration efficiency of 0.90.


2013 ◽  
Vol 68 (1) ◽  
pp. 217-226 ◽  
Author(s):  
Chol D. T. Abel ◽  
Saroj K. Sharma ◽  
Ervin Buçpapaj ◽  
Maria D. Kennedy

The effect of hydraulic loading rate (HLR) and media type on the removal of bulk organic matter and nitrogen from primary effluent during soil aquifer treatment was investigated by conducting laboratory-scale soil column studies. Two soil columns packed with silica sand were operated at HLRs of 0.625 and 1.25 m/d, while a third column was packed with dune filtering material and operated at HLR of 1.25 m/d. Bulk organic matter was effectively removed by 47.5 ± 1.2% and 45.1 ± 1.2% in silica sand columns operated at 0.625 and 1.25 m/d, respectively and 57.3 ± 7.6% in dune filtering material column operated at 1.25 m/d. Ammonium-nitrogen reduction of 74.5 ± 18.0% was achieved at 0.625 m/d compared to 39.1 ± 4.3% at 1.25 m/d in silica sand columns, whereas 49.2 ± 5.2% ammonium-nitrogen reduction was attained at 1.25 m/d in the dune filtering material column. Ammonium-nitrogen reduction in the first 3 m was assumed to be dominated by nitrification process evidenced by corresponding increase in nitrate. Part of the ammonium-nitrogen was adsorbed onto the media, which was observed at higher rates between 3 and 5 m in silica sand column operated at HLR of 0.625 m/d and dune filtering material column operated at 1.25 m/d compared to 1.25 m/d silica.


2019 ◽  
Vol 91 (5) ◽  
pp. 399-406
Author(s):  
Fanping Zheng ◽  
Linli Huang ◽  
Jing Pan ◽  
Shiyue Qi ◽  
Chaoquan Tan ◽  
...  

2012 ◽  
Vol 573-574 ◽  
pp. 659-662
Author(s):  
Hao Wang

In Tangshan area, the secondary effluent of wastewater treatment plants was used for this study. Horizontal zeolite wetland was carried out treating it. Hydraulic loading rate was the parameters for analyzing the nitrogen and phosphorus removal efficiency of pollutants from the secondary effluent of wastewater treatment plant. Zeolite constructed wetlands showed different behaviors for nitrogen and phosphorus removals.Under the optimum hydraulic loading rate, the primary pollutions were removed to a large extent.


2013 ◽  
Vol 864-867 ◽  
pp. 1498-1502
Author(s):  
Qing Feng Chen ◽  
Wen Guo Dong ◽  
Jun Jian Ma ◽  
Qing Li ◽  
Xin Guo Gao ◽  
...  

Hydraulic loading rate (HLR) is an important operational parameter for constructed wetland to purify wastewater. In this paper, it is the main objective to select the optimal parameter of HLR. During the four HLRs (i.e., 6 cm/d, 12 cm/d, 24 cm/d and 48 cm/d) operation period, six days were used as one stage. The experimental results showed that the best average removal rates of CODcr (59.7%) and NH3-N (89.4%) were at the HLR of 6 cm/d. In the meantime, the best average removal rate of total phosphorus (TP, 50.0%) was at the HLR of 24 cm/d. According to the low influent TP concentration, it is suggested that the HLR of 6 cm/d should be used in the multi-stage constructed wetland.


2016 ◽  
Vol 107 ◽  
pp. 102-112 ◽  
Author(s):  
Philani Ncube ◽  
Marc Pidou ◽  
Tom Stephenson ◽  
Bruce Jefferson ◽  
Peter Jarvis

Sign in / Sign up

Export Citation Format

Share Document