Feasibility study of round window stimulation with the MET-V implantable middle ear device: A temporal bone study

2010 ◽  
Vol 263 (1-2) ◽  
pp. 251
Author(s):  
N. Julian Holland ◽  
Kanthaiah Koka ◽  
J. Eric Lupo ◽  
Daniel J. Tollin ◽  
Herman A. Jenkins
2018 ◽  
Vol 148 ◽  
pp. 12001
Author(s):  
Rafal Rusinek ◽  
Marcin Szymanski ◽  
Grzegorz Teresinski

The paper focuses on experimental research of a middle ear prosthesis made of shape memory alloy. The prosthesis provides better adjustment to individual patient than classical prosthesis. The shape memory prosthesis is implemented to a fresh temporal bone and vibrations of the round window are recorded by means of the Laser Doppler Vibrometer. Finally, the results are presented in the form of transfer function and compared to the intact and damaged middle ear.


1983 ◽  
Vol 92 (2) ◽  
pp. 134-136 ◽  
Author(s):  
George Kelemen

The otologic literature contains no description of the histopathological features of temporal bones of persons who perished in drowning accidents. Three temporal bones from two fatal cases of drowning were studied in serial sections. Two temporal bones were from a man aged 31 years who collapsed after scuba diving and died three days later. One temporal bone was from a 32-year-old man, serving in the navy, who drove his car, probably accidentally, into the sea and drowned in it. Histopathological findings appeared to be similar in the two cases. Diffuse hemorrhage was evident throughout the middle ear and inner ear. The tympanic and round window membranes appeared to be intact although hemorrhage had occurred within the tissue layers of the membranes. This finding contrasts with observations of ruptured membranes by other investigators.


1993 ◽  
Vol 29 (5) ◽  
pp. 896
Author(s):  
Tae Beom Kweon ◽  
Hun Seong ◽  
Mal Soon Cheon ◽  
Hack Jin Kim ◽  
Keung Jae Jang ◽  
...  

Author(s):  
Beomcho Jun ◽  
Sunwha Song

Abstract Objective This paper describes the construction of portals for electrode placement during cochlear implantation and emphasises the utility of pre-operative temporal bone three-dimensional computed tomography. Methods Temporal bone three-dimensional computed tomography was used to plan portal creation for electrode insertion. Results Pre-operative temporal bone three-dimensional computed tomography can be used to determine the orientation of temporal bone structures, which is important for mastoidectomy, posterior tympanotomy and cochleostomy, and when using the round window approach. Conclusion It is essential to create appropriate portals (from the mastoid cortex to the cochlea) in a step-by-step manner, to ensure the safe insertion of electrodes into the scala tympani. Pre-operative three-dimensional temporal bone computed tomography is invaluable in this respect.


Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 946
Author(s):  
Dong Ho Shin

This report describes the design of a new piezoelectric transducer for round window (RW)-driven middle ear implants. The transducer consists of a piezoelectric element, gold-coated copper bellows, silicone elastomer (polydimethylsiloxane, PDMS), metal cylinder (tungsten), and titanium housing. The piezoelectric element is fixed to the titanium housing and mechanical resonance is generated by the interaction of the bellows, PDMS, and tungsten cylinder. The dimensions of PDMS and the tungsten cylinder with output characteristics suitable for compensation of sensorineural hearing loss were derived by mechanical vibrational analysis (equivalent mechanical model and finite element analysis (FEA)). Based on the results of FEA, the RW piezoelectric transducer was implemented, and bench tests were performed under no-load conditions to confirm the output characteristics. The transducer generates an average displacement of 219.6 nm in the flat band (0.1–1 kHz); the resonance frequency is 2.3 kHz. To evaluate the output characteristics, the response was compared to that of an earlier transducer. When driven by the same voltage (6 Vp), the flat band displacement averaged 30 nm larger than that of the other transducer, and no anti-resonance was noted. Therefore, we expect that the new transducer can serve as an output device for hearing aids, and that it will improve speech recognition and treat high-frequency sensorineural hearing loss more effectively.


Author(s):  
Sebastian Halm ◽  
David Haberthür ◽  
Elisabeth Eppler ◽  
Valentin Djonov ◽  
Andreas Arnold

Abstract Introduction This pilot study explores whether a human Thiel-embalmed temporal bone is suitable for generating an accurate and complete data set with micro-computed tomography (micro-CT) and whether solid iodine-staining improves visualization and facilitates segmentation of middle ear structures. Methods A temporal bone was used to verify the accuracy of the imaging by first digitally measuring the stapes on the tomography images and then physically under the microscope after removal from the temporal bone. All measurements were compared with literature values. The contralateral temporal bone was used to evaluate segmentation and three-dimensional (3D) modeling after iodine staining and micro-CT scanning. Results The digital and physical stapes measurements differed by 0.01–0.17 mm or 1–19%, respectively, but correlated well with the literature values. Soft tissue structures were visible in the unstained scan. However, iodine staining increased the contrast-to-noise ratio by a factor of 3.7 on average. The 3D model depicts all ossicles and soft tissue structures in detail, including the chorda tympani, which was not visible in the unstained scan. Conclusions Micro-CT imaging of a Thiel-embalmed temporal bone accurately represented the entire anatomy. Iodine staining considerably increased the contrast of soft tissues, simplified segmentation and enabled detailed 3D modeling of the middle ear.


1988 ◽  
Vol 105 (sup457) ◽  
pp. 139-143 ◽  
Author(s):  
E. M. Keithley ◽  
A. F. Ryan ◽  
J. P. Harris

1979 ◽  
Vol 88 (3) ◽  
pp. 368-376 ◽  
Author(s):  
A. Axelsson ◽  
J. Miller ◽  
M. Silverman

Acute middle ear (ME) and inner ear changes following brief unilateral phasic ME pressure changes (up to ± 6000/mm H2O) were studied in the guinea pig. Middle ear findings included perforation of the tympanic membrane, serous and serosanguinous exudate and hemorrhage of tympanic membrane and periosteal vessels. Changes were related to magnitude of applied pressure. Perforation and hemorrhage were more commonly seen with negative rather than positive pressure. Air bubbles behind the round window were seen with positive pressures. Occasional distortion, but never perforation of the round window, was noted. Hemorrhage of the scala tympani was observed with both positive and negative pressures; scala vestibuli hemorrhage was found with negative ME pressure. In some instances pressure direction and magnitude related changes were seen in the contralateral ear.


2017 ◽  
Vol 158 (1) ◽  
pp. 155-157 ◽  
Author(s):  
Thomas Muelleman ◽  
Matthew Shew ◽  
Sameer Alvi ◽  
Kushal Shah ◽  
Hinrich Staecker ◽  
...  

The presigmoid retrolabyrinthine approach to the cerebellopontine angle is traditionally described to not provide access to the internal auditory canal (IAC). We aimed to evaluate the extent of the IAC that could be exposed with endoscopically assisted drilling and to measure the percentage of the IAC that could be visualized with the microscope and various endoscopes after drilling had been completed. Presigmoid retrolabyrinthine approaches were performed bilaterally on 4 fresh cadaveric heads. We performed endoscopically assisted drilling to expose the fundus of the IAC, which resulted in exposure of the entire IAC in 8 of 8 temporal bone specimens. The microscope afforded a mean view of 83% (n = 8) of the IAC. The 0°, 30°, 45°, and 70° endoscope each afforded a view of 100% of the IAC in 8 of 8 temporal bone specimens. In conclusion, endoscopic drilling of the IAC of can provide an extradural means of exposing the entire length of the IAC while preserving the labyrinth.


Sign in / Sign up

Export Citation Format

Share Document