scholarly journals Left atrial surface area remaining not isolated after ablation of persistent atrial fibrillation predicts long-term outcomes

2015 ◽  
Vol 24 ◽  
pp. S240
Author(s):  
C. Nalliah ◽  
T. Lim ◽  
P. Qian ◽  
A. Bhaskaran ◽  
R. Kurup ◽  
...  
EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
S Kany ◽  
J Brachmann ◽  
T Lewalter ◽  
I Akin ◽  
H Sievert ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: Foundation. Main funding source(s): Stiftung für Herzinfarkforschung Background  Non-paroxysmal (NPAF) forms of atrial fibrillation (AF) have been reported to be associated with an increased risk for systemic embolism or death compared with paroxysmal AF (PAF). This study investigates the procedural safety and long-term outcomes of left atrial appendage closure (LAAC) in patients with different forms of AF. Methods  Comparison of procedural details and long-term outcomes in patients (pts) with PAF against controls with NPAF in the prospective, multicentre observational registry of patients undergoing LAAC in Germany (LAARGE).  Results  A total of 638 pts (PAF 274 pts, NPAF 364 pts) were enrolled. NPAF consisted of 31.6% patients with persistent AF and 68.4% with longstanding persistent AF or permanent AF. In both groups, a history of PVI was rare (4.0% vs 1.6%, p = 0.066). The PAF group had significantly less history of heart failure (19.0% vs 33.0%, p < 0.001) while the current median LVEF was similar (60% vs 60%, p = 0.26). The total CHA2DS2-VASc score was lower in the PAF group (4.4 ± 1.5 vs 4.6 ± 1.5, p = 0.033), but no difference in the HAS-BLED score (3.8 ± 1.1 vs 3.9 ± 1.1, p = 0.40) was observed. The rate of successful implantation was equally high (97.4% vs 97.8%, p = 0.77) in both groups. In the three-month echo follow-up, device-related thrombi (2.1% vs 7.3%, p = 0.12) and peridevice leak >5 mm (0.0% vs 7.1%, p= 0.53) were numerically higher in the NPAF group. Overall, in-hospital complications occurred in 15.0% of the PAF cohort and 10.7% of the NPAF cohort (p = 0.12). In the one-year follow-up, unadjusted mortality (8.4% vs 14.0%, p = 0.039) and combined outcome of death, stroke and systemic embolism (8.8% vs 15.1%, p = 0.022) were significantly higher in the NPAF cohort. After adjusting for CHA2DS2-VASc and previous bleeding, NPAF was associated with increased death/stroke/systemic embolism (HR 1.67, 95%-CI: 1.02-2.72). Conclusion  Atrial fibrillation type did not impair periprocedural safety or in-hospital MACE of patients undergoing LAAC. However, after one year, NPAF was associated with higher mortality and combined outcome of death, stroke and systemic embolism.


Medicina ◽  
2019 ◽  
Vol 55 (10) ◽  
pp. 709
Author(s):  
Anselmino ◽  
Rovera ◽  
Marchetto ◽  
Castagno ◽  
Morello ◽  
...  

Background and Objectives: Surgical atrial fibrillation (AF) ablation concomitant to minimally invasive mitral valve repair has been proven to offer improved short- and long-term sinus rhythm (SR) maintenance compared to mitral valve surgery only. The objective of the present study was to explore, by thorough echocardiographic assessment, long-term morphological and functional left atrial (LA) outcomes after this combined surgical procedure. Materials and Methods: From October 2006 to November 2015, 48 patients underwent minimally invasive mitral valve repair and concomitant surgical AF cryoablation. Results: After 3.8 ± 2.2 years, 30 (71.4%) of those completing the follow-up (n = 42, 87.5%) presented SR. During follow-up, four (9.5%) patients suffered from cerebrovascular accidents and two of these subjects had a long-standing persistent AF relapse and were in AF at the time of the event, while the other two were in SR. An echocardiographic study focused on LA characteristics was performed in 29 patients (69.0%). Atrial morphology and function (e.g., maximal LA volume indexed to body surface area and total LA emptying fraction derived from volumes) in patients with stable SR (60.6 ± 13.1 mL/mq and 25.1 ± 7.3%) were significantly better than in those with AF relapses (76.8 ± 16.2 mL/mq and 17.5 ± 7.4%; respectively, p = 0.008 and p = 0.015). At follow-up, patients who suffered from ischemic cerebral events had maximal LA volume indexed to body surface area 61 ± 17.8 mL/mq, with total LA emptying fraction derived from volumes 23.6 ± 13.7%; patients with strokes in SR showed very enlarged LA volume (>70 mL/mq). Conclusions: AF cryoablation concomitant with minimally invasive mitral valve repair provides a high rate of SR maintenance and this relates to improved long-term morphological and functional LA outcomes. Further prospective studies are needed to define the cut-off values determining an increase in the risk for thromboembolic complications in patients with restored stable SR.


Author(s):  
Alexey Babak ◽  
Christine Bienvenue Kauffman ◽  
Cynthia Lynady ◽  
Reginald McClellan ◽  
Kalpathi Venkatachalam ◽  
...  

Background: It is unknown whether cryoballoon technology for persistent atrial fibrillation (AF) is a reasonable initial strategy for patients with persistent AF (perAF). Methods: 390 consecutive procedures using cryoballoon for initial AF ablation were evaluated and divided first by clinical presentation: paroxysmal AF (PAF) or perAF, and then whether PV potentials associated PV pacing (PV capture) were identified after ablation. Patients were followed for recurrent AF (median 20 months). Results: PV capture was identified in patients with PAF and perAF (PAF: 20.3% vs. perAF: 14.6%; p < 0.05). No patient charactieristic differences were identified between those patients with or without PV capture. The presence of PV capture was not associated with different outcomes in patients with PAF. However, in patients with perAF, the presence of PV capture was associated with long-term outcomes similar to patients with PAF and significantly better than patients with perAF without PV capture (p < 0.001). In patients with perAF and PV capture, a strategy of reisolation of the PVs only for recurrent AF resulted in 20/23 (87%) patients in sinus rhythm off antiarrhythmic medications at study completion. In patients with PV capture, specific electrophysiologic properties of PV tissue did not have an impact on AF recurrence. Conclusion: PV capture (and not specific PV electrophysiologic characteristics) was associated with decreased recurrent AF in patients with perAF. PV capture may identify those patients with perAF in whom PV isolation alone is sufficient at initial ablation procedure and also as the primary ablation strategy for recurrent AF.


2020 ◽  
Vol 109 (1) ◽  
pp. 124-131 ◽  
Author(s):  
Elisabetta Lapenna ◽  
Michele De Bonis ◽  
Ilaria Giambuzzi ◽  
Benedetto Del Forno ◽  
Stefania Ruggeri ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document