scholarly journals 257 T Wave Inversion for Patients with HIS Bundle Pacing – A Follow up Study

2020 ◽  
Vol 29 ◽  
pp. S149
Author(s):  
M. Kalsi ◽  
V. Mutha
2019 ◽  
Vol 279 ◽  
pp. 100-104 ◽  
Author(s):  
Flavio D'Ascenzi ◽  
Francesca Anselmi ◽  
Beatrice Berti ◽  
Elena Capitani ◽  
Chiara Chiti ◽  
...  

2018 ◽  
Vol 39 (suppl_1) ◽  
Author(s):  
F D'Ascenzi ◽  
F Anselmi ◽  
B Berti ◽  
E Capitani ◽  
A Franchini ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Ciesielski ◽  
A Slawuta ◽  
A Zabek ◽  
K Boczar ◽  
B Malecka ◽  
...  

Abstract   A single-chamber ICD is a standard method for primary SCD prophylaxis. In patients with chronic atrial fibrillation it does not contribute to the regularization of heart rate, which is crucial for proper treatment. Moreover, to avoid the deleterious effect of right ventricular pacing only minority of the patients with single chamber ICD get the appropriate, recommended dose of beta-blockers. The aim of our study was to assess the efficacy of direct His-bundle pacing in a population of patients with congestive heart failure and chronic atrial fibrillation using upgrade from single chamber to dual-chamber ICD and atrial channel to perform the His-bundle pacing Methods The study population included 39 patients (37 men, 2 women) aged 67.2±9.3 years, with CHF and chronic AF implanted primarily with single chamber ICD with established pharmacotherapy and stable clinical status. Results The echocardiography measurements at baseline and during follow-up were presented in the table: During short period (3–6 months) of follow-up the mean values of EF and LV dimensions significantly improved. This was also accompanied by functional status improvement. Conclusions His-bundle-based pacing in CHF-chronic AF patients contributes to significant echocardiographic and clinical improvement. Standard single-chamber ICD implantation in CHF-chronic AF patients yields only SCD prevention without influence on remodeling process. The physiological pacing contributes to better pharmacotherapy. Funding Acknowledgement Type of funding source: None


EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_2) ◽  
pp. ii27-ii35
Author(s):  
Yiran Hu ◽  
Min Gu ◽  
Wei Hua ◽  
Hongxia Niu ◽  
Hui Li ◽  
...  

Abstract Aims His-bundle pacing (HBP) can be achieved in either atrial-side HBP (aHBP) or ventricular-side HBP (vHBP). The study compared the pacing parameters and electrophysiological characteristics between aHBP and vHBP in bradycardia patients. Methods and results Fifty patients undergoing HBP implantation assisted by visualization of the tricuspid valvular annulus (TVA) were enrolled. The HBP lead position was identified by TVA angiography. Twenty-five patients were assigned to undergo aHBP and compared with 25 patients who underwent vHBP primarily in a prospective and randomized fashion. Pacing parameters and echocardiography were routinely assessed at implant and 3-month follow-up. His-bundle pacing was successfully performed in 45 patients (90% success rate with 44.4% aHBP and 55.6% vHBP). The capture threshold was lower in vHBP than aHBP at implant (vHBP: 1.1 ± 0.5 vs. aHBP: 1.4 ± 0.4 V/1.0 ms, P = 0.014) and 3-month follow-up (vHBP: 0.8 ± 0.4 vs. aHBP: 1.7 ± 0.8 V/0.4 ms, P < 0.001). The R-wave amplitude was higher in vHBP than in aHBP at implant (vHBP: 4.5 ± 1.4 vs. aHBP: 2.0 ± 0.8 mV, P < 0.001) and at 3-month follow-up (vHBP: 4.4 ± 1.5 vs. aHBP: 1.8 ± 0.7 mV, P < 0.001). No procedure-related complications and aggravation of tricuspid valve regurgitation were observed in most patients and echocardiographic assessment of cardiac function remained in the normal range in all patients during the follow-up. Conclusion This study demonstrates that vHBP features a low and stable pacing capture threshold and high R-wave amplitude, suggesting better pacing mode management and battery longevity can be achieved by HBP in the ventricular side.


2020 ◽  
Vol 31 (2) ◽  
pp. 177-182 ◽  
Author(s):  
Elise Bakelants ◽  
Alwin Zweerink ◽  
Haran Burri
Keyword(s):  

2020 ◽  
Vol 6 (7) ◽  
pp. 883-900 ◽  
Author(s):  
Haran Burri ◽  
Marek Jastrzebski ◽  
Pugazhendhi Vijayaraman
Keyword(s):  

2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
A Slawuta ◽  
K Boczar ◽  
A Zabek ◽  
A Ciesielski ◽  
J Hiczkiewicz ◽  
...  

Abstract The heart rate regularization is crucial for proper treatment of patients with atrial fibrillation and congestive heart failure. The standard resynchronization can be applied, but in patients with narrow QRS this procedure is of no use. The aim of our study is to assess the efficacy of direct His-bundle pacing in patients with congestive heart failure and chronic atrial fibrillation using dual chamber ICD implanted for prevention of sudden cardiac death. Methods The study population included 78 patients with CHF and chronic AF: group A - 56 pts treated with direct His-bundle pacing using atrial port of dual chamber ICD and group B - 22 patients implanted with single chamber ICD as recommended by the guidelines. The patients in group B constituting clinical controls were derived from the Heart Failure Outpatients Clinic with established clinical status and pharmacotherapy. Results The demographic data, clinical characteristics and echocardiography measurements at baseline and during follow-up were presented in the table: Table 1 Group A Group B P value Age (years) 69.7±6.9 66.7±11.3 n.s. Sex (% of male sex) 84.0 86.4 n.s. Ventricular pacing (%) – 46.3±31.2 – His-bundle pacing (%) 81.7±9.2 – – pre post pre post pre vs. post LVEDD (mm) 66.9±4.9 59.9±4.7 64.8±8.0 64.7±8.1 <0.01 n.s. EF (%) 29.6±3.8 43.6±5.9 28.1±6.1 28.8±7.3 <0.01 n.s. NYHA class 2.7±0.6 1.4±0.6 2.5±0.6 2.0±0.2 <0.05 n.s. B-blocker dose (metoprolol equivalent dose) 104.6±41.6 214.3±82.6 78.3±56.6 103.1±49.2 <0.001 <0.05 During 12-months of follow-up the mean values of NYHA functional class, EF and LV dimensions did not change in group B but significantly improved in group A. The physiological His-bundle based pacing enabled optimal beta-blocker dosing. The studied groups had no tachyarrhythmia at baseline so the presumable atrial fibrillation-related harm depends on the rhythm irregularity. Conclusions His-bundle-based pacing in CHF-chronic AF patients contributes to significant echocardiographic and clinical improvement. Standard single-chamber ICD implantation in CHF-chronic AF patients yields only SCD prevention without influence on remodeling process. The CHF-patients with narrow QRS and chronic AF benefit from substantially higher beta-blockade which can be instituted in His-bundle pacing group.


Heart ◽  
2018 ◽  
Vol 105 (2) ◽  
pp. 137-143 ◽  
Author(s):  
Weijian Huang ◽  
Lan Su ◽  
Shengjie Wu ◽  
Lei Xu ◽  
Fangyi Xiao ◽  
...  

ObjectivesHis bundle pacing (HBP) can potentially correct left bundle branch block (LBBB). We aimed to assess the efficacy of HBP to correct LBBB and long-term clinical outcomes with HBP in patients with heart failure (HF).MethodsThis is an observational study of patients with HF with typical LBBB who were indicated for pacing therapy and were consecutively enrolled from one centre. Permanent HBP leads were implanted if the LBBB correction threshold was <3.5V/0.5 ms or 3.0 V/1.0 ms. Pacing parameters, left ventricular ejection fraction (LVEF), left ventricular end-systolic volume (LVESV) and New York Heart Association (NYHA) Class were assessed during follow-up.ResultsIn 74 enrolled patients (69.6±9.2 years and 43 men), LBBB correction was acutely achieved in 72 (97.3%) patients, and 56 (75.7%) patients received permanent HBP (pHBP) while 18 patients did not receive permanent HBP (non-permanent HBP), due to no LBBB correction (n=2), high LBBB correction thresholds (n=10) and fixation failure (n=6). The median follow-up period of pHBP was 37.1 (range 15.0–48.7) months. Thirty patients with pHBP had completed 3-year follow-up, with LVEF increased from baseline 32.4±8.9% to 55.9±10.7% (p<0.001), LVESV decreased from a baseline of 137.9±64.1 mL to 52.4±32.6 mL (p<0.001) and NYHA Class improvement from baseline 2.73±0.58 to 1.03±0.18 (p<0.001). LBBB correction threshold remained stable with acute threshold of 2.13±1.19 V/0.5 ms to 2.29±0.92 V/0.5 ms at 3-year follow-up (p>0.05).ConclusionspHBP improved LVEF, LVESV and NYHA Class in patients with HF with typical LBBB.


2019 ◽  
Vol 48 (2) ◽  
pp. 030006051988418
Author(s):  
Fei Liu ◽  
Lijun Zeng ◽  
Xiaomeng Yin ◽  
Lianjun Gao ◽  
Yunlong Xia ◽  
...  

A 61-year-old woman was referred to our institution for evaluation of severe nonischemic dilated cardiomyopathy and left bundle branch block (LBBB). After permanent His bundle pacing, the LBBB was immediately corrected; however, the right bundle branch was injured during the procedure. Subsequent recovery of the right bundle branch block and normalization of heart function were observed during follow-up. This case indicates that LBBB might result in the development of nonischemic cardiomyopathy and emphasizes the necessity of a temporary pacemaker during His bundle pacing for patients with LBBB.


Sign in / Sign up

Export Citation Format

Share Document