scholarly journals Application of a quartz crystal microbalance to measure the mass concentration of combustion particle suspensions

2019 ◽  
Vol 137 ◽  
pp. 105445 ◽  
Author(s):  
Kamaljeet Kaur ◽  
Raziye Mohammadpour ◽  
Isabel C. Jaramillo ◽  
Hamidreza Ghandehari ◽  
Christopher Reilly ◽  
...  
2015 ◽  
Vol 8 (12) ◽  
pp. 12887-12931
Author(s):  
B. Sarangi ◽  
S. G. Aggarwal ◽  
D. Sinha ◽  
P. K. Gupta

Abstract. In this work, we have used scanning mobility particle sizer (SMPS) and quartz crystal microbalance (QCM) to estimate the effective density of aerosol particles. This approach is tested for aerosolized particles generated from the solution of standard materials of known density, i.e. ammonium sulfate (AS), ammonium nitrate (AN) and sodium chloride (SC), and also applied for ambient measurement in New Delhi. We also discuss uncertainty involved in the measurement. In this method, dried particles are introduced in to a differential mobility analyzer (DMA), where size segregation was done based on particle electrical mobility. At the downstream of DMA, the aerosol stream is subdivided into two parts. One is sent to a condensation particle counter (CPC) to measure particle number concentration, whereas other one is sent to QCM to measure the particle mass concentration simultaneously. Based on particle volume derived from size distribution data of SMPS and mass concentration data obtained from QCM, the mean effective density (ρeff) with uncertainty of inorganic salt particles (for particle count mean diameter (CMD) over a size range 10 to 478 nm), i.e. AS, SC and AN is estimated to be 1.76 ± 0.24, 2.08 ± 0.19 and 1.69 ± 0.28 g cm−3, which are comparable with the material density (ρ) values, 1.77, 2.17 and 1.72 g cm−3, respectively. Among individual uncertainty components, repeatability of particle mass obtained by QCM, QCM crystal frequency, CPC counting efficiency, and equivalence of CPC and QCM derived volume are the major contributors to the expanded uncertainty (at k = 2) in comparison to other components, e.g. diffusion correction, charge correction, etc. Effective density for ambient particles at the beginning of winter period in New Delhi is measured to be 1.28 ± 0.12 g cm−3. It was found that in general, mid-day effective density of ambient aerosols increases with increase in CMD of particle size measurement but particle photochemistry is an important factor to govern this trend. It is further observed that the CMD has good correlation with O3, SO2 and ambient RH, suggesting that possibly sulfate secondary materials have substantial contribution in particle effective density. This approach can be useful for real-time measurement of effective density of both laboratory generated and ambient aerosol particles, which is very important for studying the physico-chemical property of particles.


2004 ◽  
Vol 22 (10) ◽  
pp. 3347-3351 ◽  
Author(s):  
P. S. Pillai ◽  
K. Krishna Moorthy

Abstract. Simultaneous data on Aerosol Optical Depth (AOD) and size segregated, near-surface, aerosol mass concentration was obtained from a Multi wavelength Solar Radiometer (MWR) and Quartz Crystal Microbalance Impactor (QCM), respectively. These were used to examine the association between near-surface aerosol properties and columnar AOD. The spectral AODs were approximated to the Ångström relation τp=βλ-α, and the wavelength exponent α and turbidity coefficient β have been obtained. In general, α was found to be well associated with the relative abundance of accumulation mode aerosols (estimated from the simultaneous QCM data) while β followed the variations of the coarse mode aerosol mass concentration; the association being closer during periods of continental airmass.


2016 ◽  
Vol 9 (3) ◽  
pp. 859-875 ◽  
Author(s):  
Bighnaraj Sarangi ◽  
Shankar G. Aggarwal ◽  
Deepak Sinha ◽  
Prabhat K. Gupta

Abstract. In this work, we have used a scanning mobility particle sizer (SMPS) and a quartz crystal microbalance (QCM) to estimate the effective density of aerosol particles. This approach is tested for aerosolized particles generated from the solution of standard materials of known density, i.e. ammonium sulfate (AS), ammonium nitrate (AN) and sodium chloride (SC), and also applied for ambient measurement in New Delhi. We also discuss uncertainty involved in the measurement. In this method, dried particles are introduced in to a differential mobility analyser (DMA), where size segregation is done based on particle electrical mobility. Downstream of the DMA, the aerosol stream is subdivided into two parts. One is sent to a condensation particle counter (CPC) to measure particle number concentration, whereas the other one is sent to the QCM to measure the particle mass concentration simultaneously. Based on particle volume derived from size distribution data of the SMPS and mass concentration data obtained from the QCM, the mean effective density (ρeff) with uncertainty of inorganic salt particles (for particle count mean diameter (CMD) over a size range 10–478 nm), i.e. AS, SC and AN, is estimated to be 1.76 ± 0.24, 2.08 ± 0.19 and 1.69 ± 0.28 g cm−3, values which are comparable with the material density (ρ) values, 1.77, 2.17 and 1.72 g cm−3, respectively. Using this technique, the percentage contribution of error in the measurement of effective density is calculated to be in the range of 9–17 %. Among the individual uncertainty components, repeatability of particle mass obtained by the QCM, the QCM crystal frequency, CPC counting efficiency, and the equivalence of CPC- and QCM-derived volume are the major contributors to the expanded uncertainty (at k = 2) in comparison to other components, e.g. diffusion correction, charge correction, etc. Effective density for ambient particles at the beginning of the winter period in New Delhi was measured to be 1.28 ± 0.12 g cm−3. It was found that in general, mid-day effective density of ambient aerosols increases with increase in CMD of particle size measurement but particle photochemistry is an important factor to govern this trend. It is further observed that the CMD has good correlation with O3, SO2 and ambient RH, suggesting that possibly sulfate secondary materials have a substantial contribution in particle effective density. This approach can be useful for real-time measurement of effective density of both laboratory-generated and ambient aerosol particles, which is very important for studying the physico-chemical properties of particles.


IEEE Access ◽  
2019 ◽  
Vol 7 ◽  
pp. 170640-170647
Author(s):  
Nhan Dinh Ngo ◽  
Jaegil Lee ◽  
Myeong-Woo Kim ◽  
Jaesung Jang

2011 ◽  
Vol 22 (11) ◽  
pp. 115102 ◽  
Author(s):  
A Hevroni ◽  
H Golan ◽  
A Fialkov ◽  
I Rahinov ◽  
V Tsionsky ◽  
...  

2019 ◽  
Vol 25 (6) ◽  
pp. 879-884
Author(s):  
Takahiro Sakai ◽  
Hayato Seki ◽  
Shogo Yoshida ◽  
Hayato Hori ◽  
Hisashi Suzuki ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document